Copper Service Entrance (SE) Cable

Home > Products > Concentric Cable > Copper Service Entrance (SE) Cable

Copper Service Entrance (SE) Cable

Copper SE cable – premium choice for safe, high-efficiency service entrances.

Superior conductivity and performance for demanding residential loads.

Built with copper conductors for long-term durability and minimal voltage drop.

Ideal for underground or overhead entry – fire-rated and flexible.

Heavy-duty copper SE cable – trusted in commercial and high-end residential wiring.

Application

Copper Service Entrance (SE) Cable is engineered for reliable power delivery from utility connections to residential, commercial, and light industrial buildings. Featuring high-purity, annealed stranded copper conductors, this cable provides superior electrical conductivity, corrosion resistance, and excellent mechanical flexibility compared to aluminum counterparts.

The cable is insulated with durable PVC or sunlight-resistant thermoplastic jackets, designed to withstand outdoor exposure, moisture, and temperature variations. Copper SE cables are commonly available in two- or three-conductor configurations, including a bare or insulated copper ground wire for enhanced safety and fault protection.

Their robust design makes them suitable for service entrance wiring, panel feeders, and branch circuits requiring high reliability.

Copper SE cables are preferred where maximum conductivity, long-term durability, and minimal voltage drop are critical. Though typically more expensive than aluminum, copper cables deliver better performance in demanding environments and tighter installation spaces.

Specifications

CategoryTechnical DescriptionTypical Applications
Cable TypeService Entrance (SE) Cable with stranded copper conductors, designed to provide main power feed from utility meter to building panelsIdeal for residential, commercial, and industrial buildings requiring high reliability power distribution
Conductor Material– High-purity annealed copper, Class B or C stranded for excellent conductivity and mechanical flexibilitySuperior electrical conductivity and thermal performance compared to aluminum
Construction– Multiple insulated copper conductors with color-coded insulation- Bare or insulated copper grounding conductor- Flame-retardant PVC sheathEnsures robust mechanical protection and long service life
Insulation & Jacket– Insulation typically XHHW-2 or THHN/THWN-2– Outer jacket: sunlight-resistant PVC or thermoplastic elastomerSuitable for wet/dry locations, outdoor exposures, and conduit installations
Voltage RatingRated for 600 V, suitable for typical building distribution voltage levelsComplies with NEC and UL standards for service entrance cables
Standards ComplianceMeets UL 44, UL 1277, NEC Article 338, CSA C22.2, and ASTM specificationsEnsures safety, durability, and performance in demanding electrical environments



Parameter

ConductorStrandngNomnina
0.D.(MIs)
Allowable AmpactiesApprodimat
 e Net Weight Per
 1000(Lbs)
Standard
Package
SizeConst, AWG or kcmilPhase Conductor & NeutralEquipmentGround
Conduclor
60℃75℃90℃Dwelling
8-8-8-87586405055231B
6-6-67669556575338B
4-4-47764708595100498B
3-3-3782985100110110611B
2-2-2789695115130125752B
1-1-1191021110130150150948C
1/0-1/0-1/01911141251501701751169C
2/0-2/0-2/01912091451751952001444C
3/0-3/0-3/01913171652002252251792C
4/0-4/0-4/01914381952302602502226C
SER  Three Conduclor With Bare Ground (Formerly relerred to as “Four Conductor”)
8-8-8-877645405055286B
6-6-6-677738556575424B
4-4-4-677844708595100585B
3-3-3-57791085100110110719B
2-2-2-47798495115130125887B
1-1-1-3191911321101301501501117C
1/0-1/0-1/0-2191912351251501701751382C
2/0-2/0-2/0-1191913421451751952001713C
3/0-3/0-3/0-1/0191914621651751952252129C
4/0-4/0-4/0-2/0191915981952302602502650C
Table values reflect XHHW-2 conductorsPackage
Codes:
A-250′
B-500′
C- 1,000′
D-100′
E-150′
Alow able ampacities shown are for general use as specified by the National Electrical Code, 2011 Edition section 310.15 and 240.4(D).
Unless the is marked for use at higher temperatures the conductor ampacities shall be limited to the following per NEC 110.14(C)
60 °C When terminated to equipment for circuits rated 100 amperes orless or marked for 14 – 1 AWG conductors.
75 ° C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than  1 AWG.
90 °C XHHW wet or Dry locations for ampacity adjustment purposes using NEC section 310.1 5For dwelling ampacity use section 310.15(B)(7)

 

ConductorStrandngNomnina
0.D.(MIs)
Allowable AmpactiesApprodimateNet Weight
Per 1000(Lbs)
Standard
Package
SizeConst, AWG or kcmilPhase Conductor & NeutralEquipmentGround
Conduclor
60℃75℃90℃Dwelling
10-10-10112428×283303030127ABC
8-8-878587×380405060211ABC
6-6-6712659×416556575308BCE
4-4-4712815×506708595100471BCE
3-3-3712883×54885100110110583B
2-2-2715994×57895115130125718BD
1-1-119141093×664110130150150904B
1/0-1/0-1/019181179×7071251501701751123BC
2/0-2/0-2/019181283×7671451751952001379BC
3/0-3/0-3/019141429×8621652002252251712BD
4/0-4/0-4/019181541×9181952302602502146BC
SEU Two Conductor With Bare Conentric Ground(Formerly relerred to as “Three Conductor”)(Reduced Neutral)
6-6-878659×416556575281BC
4-4-6712790×481708595100420BC
3-3-5715843×50885100110110515BC
2-2-4715929×56395115130125639BC
Table values reflect XHHW-2 conductorsPackage
Codes:
A-250′
B-500′
C- 1,000′
D-100′
E-150′
Alow able ampacities shown are for general use as specified by the National Electrical Code, 2011 Edition section 310.15 and 240.4(D).
Unless the is marked for use at higher temperatures the conductor ampacities shall be limited to the following per NEC 110.14(C)
60 °C When terminated to equipment for circuits rated 100 amperes orless or marked for 14 – 1 AWG conductors.
75 ° C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than  1 AWG.
90 °C XHHW wet or Dry locations for ampacity adjustment purposes using NEC section 310.1 5For dwelling ampacity use section 310.15(B)(7)

 

PDF Download

PDF Download

WHY CHOOSE US

INOUIRY NOW

CONTACT US

24-hour online service

Own factory processing

PRODUCT CATEGORY

HOT-SALE PRODUCT

CNE cable solutions for industrial and commercial…

Factory-quality SNE cable meeting international …

Compact design with aluminum conductor and…

Aluminum SE cable – trusted for residential service…

CONTACT USIMMEDIATELY