Application

ACS (Aluminum-Clad Steel) is a high-strength metal conductor consisting of a steel core covered with a pure aluminum layer. It combines the mechanical strength of steel with the electrical conductivity and corrosion resistance of aluminum. Its production process uses a metallurgical bonding method to tightly combine aluminum and steel to form a permanent composite material with excellent electrical conductivity, corrosion resistance and structural stability.

Compared with ordinary galvanized steel wire, ACS conductors have a longer service life in harsh environments (such as seaside, high salt fog, and acid rain areas). Its aluminum layer can effectively prevent steel oxidation and has good electrical connection performance. It is often used in conjunction with aluminum stranded wire to reduce electrochemical corrosion caused by potential difference.

ACS conductors are widely used in load-bearing components in overhead transmission lines, such as aluminum core stranded wire (ACSR), aluminum alloy conductor (AAACSR), OPGW optical cable core wire, etc. It can replace traditional galvanized steel wire to improve the corrosion resistance and service life of the line while reducing maintenance costs.

Specifications

StandardOrganizationMaterialTypical Application
ASTM B 415-1ASTM (USA)Aluminum-Clad Steel Wire, Class A– ~10% aluminum by cross-section- Steel: high-strength carbon steel- Aluminum: metallurgically bonded (not coated)Used in ground wires (shield wires), guy wires, and as core for overhead conductors where moderate conductivity and high strength are needed
ASTM B 415-2ASTM (USA)Aluminum-Clad Steel Wire, Class B or C– Higher aluminum content than Class A- Improved conductivity, lower strength vs Class AUsed where higher corrosion resistance or conductivity is desired, such as coastal regions or long-span shield wires
ASTM B 502ASTM (USA)Zinc-Coated (Galvanized) Steel Core Wire for ACSRNot ACS, but galvanized steelCore wire used in ACSR conductors; not aluminum-clad, but zinc-coated for corrosion resistance



Parameter

Size
AWG
DiameterTensile StrengthCross sectionD C Resistance at 20Nominal WeightMinimum Thickness of Aluminum
Cladding
in.mmksiN/mmin2mm2Ω/kmIb/1000ftKa/kminmm
   (CONDUCTIVITY = 20.3 % IACS) 
40.2045.18915510700.0327821.1494.0193.67139.370.010220.259
0.1884.77516011000.0277617.9094.73579.32118.020.00940.239
50.1824.6216511400.0259916.7665.05874.25110.490.00910.231
0.1734.39217011700.0234815.1485.59867.0999.820.008650.22
60.1624.11517512100.0206113.2986.37758.8987.630.00810.206
0.1553.93418012400.0188412.1586.97553.8480.120.007750.197
70.1443.66518512800.0163510.5518.03746.7369.530.007220.183
0.1373.47719013100.014729.4978.9342.0662.580.006850.174
80.1293.26419513400.012978.36710.13537.0655.140.006430.163
90.1142.90619513400.010286.63112.78729.3743.70.005720.145
100.1022.58819513400.008165.26116.11723.334.670.00510.129
110.0912.30419513400.006464.16820.34318.4627.470.004540.115
120.0812.05219513400.005133.30825.63414.6521.80.004040.103

 

Size
AWG
DiameterTensile StrengthCross sectionD C Resistance at 20Nominal WeightMinimum Thickness of Aluminum
Cladding
in.mmksiN/mm2in2mm2Ω/kmIb/1000 ftKg/kminmm
  (CONDUCTIVITY=27 %IACS) 
40.2045.1891258620.0327821.1493.01984124.990.01430.363
0.1884.7751298890.0277617.9093.56671.13105.840.013160.334
50.1824.621339170.0259916.7663.80966.5999.090.012730.323
0.1734.3921379450.0234815.1484.21660.1689.520.01210.307
60.1624.1151419720.0206113.2984.80252.8278.590.011340.288
0.1553.93414510000.0188412.1585.25248.2971.850.010840.275
70.1443.66515010340.0163510.5516.05241.9162.360.01010.257
0.1373.47715410620.014729.4976.72437.7256.120.009580.243
80.1293.26415610760.012978.3677.63233.2349.450.0090.228
90.1142.90615610760.010286.6319.62926.3439.190.008010.203
100.1022.58815610760.008165.26112.13620.931.10.007130.181
110.0912.30415610760.006464.16815.31916.5624.640.006350.161
120.0812.05215610760.005133.30819.30313.1419.550.005660.144
(CONDUCTIVITY = 30 % IACS)
40.2045.1891027030.0327821.1492.71779.74118.650.015320.389
0.1884.7751067310.0277617.9093.20967.52100.470.01410.358
50.1824.621107580.0259916.7663.42863.2194.060.013640.347
0.1734.3921147860.0234815.1483.79457.1184.980.012970.329
60.1624.1151147860.0206113.2984.32250.1474.60.012150.309
0.1553.9341188140.0188412.1584.72745.8468.210.011620.295
70.1443.6651228410.0163510.5515.44739.7859.190.010820.275
0.1373.4771268690.014729.4976.05235.853.280.010270.261
80.1293.2641288830.012978.3676.86931.5446.940.009640.245
90.1142.9061288830.010286.6318.6662537.20.008580.218
100.1022.5881288830.008165.26110.92319.8429.520.007640.194
110.0912.3041288830.006464.16813.78715.7223.380.00680.173
120.0812.0521288830.005133.30817.37212.4718.560.006060.154
 (CONDUCTIVITY= 40 %IACS)
40.2045.189805520.0327821.1492.03865.9598.130.025540.649
0.1884.775845790.0277617.9092.40755.8583.10.02350.597
50.1824.62886070.0259916.7662.57152.2877.790.022740.578
0.1734.392926340.0234815.1482.84547.2370.290.021610.549
60.1624.115966620.0206113.2983.24141.4761.70.020250.514
0.1553.934966620.0188412.1583.54537.9156.410.019360.492
70.1443.665986760.0163510.5514.08532.948.960.018040.458
0.1373.477986760.014729.4974.53929.6144.060.017110.435
80.1293.26499.56860.012978.3675.15226.0938.820.016060.408
90.1142.90699.56860.010286.6316.520.6830.770.01430.363
100.1022.58899.56860.008165.2618.19216.4124.410.012740.324
110.0912.30499.56860.006464.16810.341319.340.011340.288
120.0812.05299.56860.005133.30813.02910.3215.350.01010.257

 

SINGLE WVIRE AS PER ASTM B 502 STANDARD
Diam etorTens ile StrengthStress at 1% ExtensionResistivityDensity
in.mmksiN/m㎡ksiN/mmQ.Cmil/Hn0mlb/in3g/cm
3
0.0770-0.12891.956~3.2741951344175120651.0184.80.23816.59
0.1290-0.13693.275~3.47719013101701172
0.1370-0.14433.478-3.66518512751651137
0.1444-0.15493.666-3.93418012411601103
0.1550-0.16203.935~4.11517512061601103
0.1621~0.17294.116~4.39217011721551068
0.1730~0.18194.393~4.62016511371501034
0.1820~0.18804.621~4.77516011031451000
Coefficient of linear expansion  :12.6×10/℃
Modulus of Elasticity     : 23500 Ksl (162000 MPa)
Temperature coefficient of Resistance: 0.0036/℃C
Minimum Aluminum Thickness  : 10% of nominal wire radius
SINGLE WIRE AS PER AS-3607 STANDARD
Diameter (一)Tensile StrengthCross sactionDC Resistance a120℃Nominal WeightMinimum Thickness of Aluminum
Cladding
SHdMaxMinN/mm2KNmm0/kmKg/kmin
1.61.641.5613402.692.01142.2813.250.08
1.751.791.7113403.222.40535.3415.850.088
2.252.292.2113405.333.97621.3826.20.113
2.52.542.4613406.584.90917.3232.350.125
2.752.7912.70913407.965.9414.3139.140.138
33.0452.95513409.477.06912.0346.580.15
3.253.2993.201134011.128.29610.2554.670.163
3.53.5533.448131012.69.6218.8363.40.175
3.753.8063.694127014.0311.0457.772.780.188
Coefficient of linear expansion  :12.9×10*/℃
Modulus of Elasticity      :23500 Ksi (162000 MPa)
Tem perature coefficient of Resistance: 0.0036℃
Minimum Aluminum Thickness  : 10% of nominal wire radlus

 