AAC-All Aluminum Conductor

Home > Products > Bare Conductor > AAC-All Aluminum Conductor

AAC-All Aluminum Conductor

AAC conductor for sale

Overhead conductor factory

99.5% purity aluminum AAC

AAC conductor price per meter

AAC cable for urban network

Application

The bare conductor is made of hard-drawn aluminum wire, which is continuously twisted at a certain pitch. The twist directions of adjacent layers of the wire are opposite, and the outermost layer is twisted in the right direction..

Composed of stranded aluminum wire, AAC is available in single-ply and multi-ply constructions.,Suitable for overhead power transmission with short span, low salt spray areas, overhead feeders and busbars of substations.

Specifications

 

StandardCountry / OrganizationMaterialTypical Application
GB/T 1179ChinaAluminum stranded wire (AAC), aluminum steel core stranded wire (ACSR), aluminum alloy stranded wire (AAAC), etc. Aluminum: 1350-H19- Core: Galvanized steel wireUsed in overhead power transmission lines (35kV and above) across China
ASTM B 231USA (ASTM)AAC – All-Aluminum Conductor- Aluminum: 1350-H19 (hard drawn EC-grade aluminum)Overhead distribution and transmission lines in the USA and other countries using ASTM standards
DIN 48201-5GermanyAAC – All-Aluminum Conductor- Aluminum: EN AW-1350 or equivalentOverhead low and medium voltage power lines in Germany and nearby regions
BS 215-1United KingdomAAC – All-Aluminum Conductor- Aluminum: 1350-H19 or equivalentOverhead lines in the UK and Commonwealth countries
BS EN 50182European Union (EN)AAC, AAAC, ACSR – Concentric Lay Stranded Conductors- Aluminum or aluminum alloy- Steel (for ACSR)Common European standard for overhead line conductors
AS/NZS 1531Australia / New ZealandAAC, AAAC, ACSR- Aluminum: 1350 or aluminum alloy- Steel core: Galvanized or aluminum-cladUsed in overhead transmission and distribution systems in Australia and New Zealand
IEC 61089International (IEC)AAC, AAAC, ACSR- Aluminum: EC-grade hard drawn or alloy- Core: Galvanized or aluminum-clad steelGlobal standard for overhead line conductors in international projects

Parameter

Nominal Area Stranding Number Diameter Calculated Area Overall Diameter D,C. Resistance Calculated Breaking Calculated Weight Coefficient Linear expansion Continuous Carrying Capacity(A)
mm2No. mmmm2mmΩ/kmLoad Nkg/km1/°C70 ℃ 80 ℃ 90 ℃ 
167/1.7015.89 5.10 1.80200 284043.5 23Χ10-684100112
257/2.1525.41 6.45 1.12700 435569.6 23Χ10-6112133151
357/2.5034.36 7.50 0.83320 576094.1 23Χ10-6135161183
507/3.0049.48 9.00 0.57860 7930135.5 23Χ10-6168202230
707/3.6071.25 10.80 0.40180 10950195.1 23Χ10-6210253289
957/4.1695.14 12.48 0.30090 14450260.5 23Χ10-6250304347
12019/2.85121.21 14.25 0.23730 19420333.5 23Χ10-6289353405
15019/3.15148.07 15.75 0.19430 23310407.4 23Χ10-6327400460
18519/3.50182.80 17.50 0.15740 28440503.0 23Χ10-6371456526
21019/3.75209. 8518.75 0.13710 32260577.4 23Χ10-6403497574
24019/4.00238.76 20.00 0.12050 36260656.9 23Χ10-6435538522
30037/3.20297.57 22.40 0.09689 46850820.4 23Χ10-6496617715
40037/3.70397.83 25.90 0.07247 611501097.0 23Χ10-6588738859
50037/4.16502.90 29.12 0.05733 763701387.0 23Χ10-6674852995
63061/3.63631.30 32.67 0.04577 919401744.0 23Χ10-67689771145
80061/4.10805.36 36.90 0.03588 1159002225.0 23Χ10-688011291328

 

Code NameTotal AreaStranding and wire diameterApproximate Overall DiameterLinear MassNominal breaking LoadCoefficient Linear expansion Maximum Resistance at 20℃ Current
Rating
AWG or MCMmm2mmmmKg/kmdaN1/°CΩ/kmA
Peachbell613.29 7/1.5544.67 36.2 24923Χ10-62.1692 72 
Rose421.16 7/1.9615.89 57.7 39623Χ10-61.3624 104 
Iris233.61 7/2.4747.42 91.9 59723Χ10-60.8577 136 
Pansy142.39 7/2.7768.33 115.7 73223Χ10-60.6801 157 
Poppy1/053.48 7/3.1199.36 146.0 87323Χ10-60.5390 180 
Aster2/067.42 7/3.50310.51 184.2 110023Χ10-60.4276 207 
Phlox3/085.03 7/3.93211.80 232.1 134723Χ10-60.3390 237 
Oxlip4/0107.23 7/4.41713.26 292.8 169823Χ10-60.2688 273 
Valerian 250126.71 19/2.91314.57 349.1 206223Χ10-60.2275 305 
Sneezewort250126.71 7/4.8014.40 345.8 200723Χ10-60.2275 300 
Laurel266.8135.16 19/3.0115.05 372.8 220023Χ10-60.2133 317 
Daisy266.8135.16 7/4.9614.90 369.2 214123Χ10-60.2133 313 
Peony300152.00 19/3.193  15.97 419.5 240323Χ10-60.1896 340 
Tulip336.4170.45 19/3.38116.91 470.3 269523Χ10-60.1691 364 
Daffodil350177.35 19/3.44717.24 488.8 280423Χ10-60.1625 373 
Canna397.5201.42 19/3.67318.36 555.1 318423Χ10-60.1431 401 
Goldentuft450228.00 19/3.90919.55 628.7 349923Χ10-60.1264 432 
Syringa477241.68 37/2.88220.19 665.5 384923Χ10-60.1193 449 
Cosmos477241.68 19/4.02320.12 665.9 370823Χ10-60.1193 447 
Hyacinth500253.35 37/2.95120.65 697.7 403523Χ10-60.1138 461 
Zinnia500253.35 19/4.1220.60 698.4 388823Χ10-60.1138 459 
Dahlia556.5282.00 19/4.34621.73 777.1 432723Χ10-60.1022 489 
Mistletoe556.5282.00 37/3.11421.79 776.9 436223Χ10-60.1022 493 
Meadowsweet600304.00 37/3.23322.63 837.4 470323Χ10-60.0948 513 
Orchid636322.25 37/3.3323.31 888.4 498523Χ10-60.0894 531 
Flag70054.71 61/2.7224.48 977.2 514623Χ10-60.0813 563 
Verbena700354.71 37/3.49324.45 977.5 548723Χ10-60.0813 562 
Nasturtium715.5362.58 61/2.7524.76 998.9 587423Χ10-60.0795 570 
Violet715.5362.58 37/3.53324.74 1000.1 560923Χ10-60.0795 570 
Cattail750380.00 61/2.81725.35 1048.2 598523Χ10-60.0759 586 
Petunia750380.00 37/3.61725.32 1048.2 587523Χ10-60.0759 585 
Lilac795402.84 61/2. 9026.11 1110.9 634523Χ10-60.0715 607 
Arbutus795402.84 37/3.724 26.06 1111.1 623223Χ10-60.0715 605 
Snapdragon900456.06 61/3.08627.78 1257.9 697823Χ10-60.0632 653 
Cockscomb900456.06 37/3.96227.73 1257.7 684823Χ10-60.0632 651 
Goldenrod954483.42 61/3.17728.60 1333.2 789623Χ10-60.0596 675 
Magnolia954483.42 37/4.07928.55 1333.0 725823Χ10-60.0596 674 
Camellia1000506.71 61/3.25129.36 1396.0 775323Χ10-60.0569 693 
Hawkweed1000506.71 37/4.17629.23 1397.2 760823Χ10-60.0569 693 
Larkspur1033.5523.68 61/3.30729.76 1444.6 801223Χ10-60.0550 707 
Bluebell1033.5523.68 37/4.244   29.72 1443.1 786323Χ10-60.0550 706 
Marigold1113563.93 61/3.43230.89 1555.8 862823Χ10-60.0511 738 
Hawthorn1192.5604.26 61/3.55131.95 1665.6 924523Χ10-60.0477 767 
Narcissus1272644.51 61/3.66833.02 1777.2 986123Χ10-60.0477 797 
Columbine1351.5684.84 61/3.7834.01 1887.3 1047823Χ10-60.0421 825 
Carnation   1431725.10 61/3.8935.03 1998.8 1076823Χ10-60.0398 854 
Gladiolus1510.5765.35 61/4.0036.00 2113.4 1136523Χ10-60.0376 881 
Coreopsis 1590805.68 61/4.09936.90 2219.3 1196423Χ10-60.0358 907 
Jessamine1750886.71 61/4.30238.73 2444.6 1316823Χ10-60.0325 959 
Cowslip20001013.42 91/3.7641.40 2785.8 1530023Χ10-60.0285 1035 
Sagebrush22501013.42 91/3.9943.89 3152.4 1704323Χ10-60.0256 1035 
Lupine25001266.67 91/4.21  46.30 3492.6 1870023Χ10-60.0230 1108 
Trilium30001520.13 127/3.9050.75 4182.8 2250023Χ10-60.0192 1308 
Blue Bonnet35001773.50 127/4.2154.80 4874.2 2620023Χ10-60.0166 1425 

 

Nominal cross-section mm2Actual cross-section mm2Stranding and wire DiameterOverall Diameter mmLinear Mass Calculated Breaking Load daNCoefficient Linear expansion
1/°C 
Maximum D.C. Resistance at 20℃ Ω/kmCurrent
Rating
kg/kmA
1615.89 7/1.705.10 4429023Χ10-61.80180 110
2524.25 7/2.106.30 6742523Χ10-61.18080 145
3534.36 7/2.507.50 9458523Χ10-60.83320 180
5049.48 7/3.009.00 13581023Χ10-60.57860 225
5048.36 19/1.809.00 13386023Χ10-60.59500 225
7065.82 19/2.1010.50 181115023Χ10-60.43710 270
9593.27 19/2.5012.50 256159523Χ10-60.30840 340
120117.00 19/2.8014.00 322191023Χ10-60.24590 390
150147.10 37/2.2515.20 406257023Χ10-60.19600 455
185181.60 37/2.5017.50 501310523Χ10-60.15870 520
240242.54 61/2.2520.20 670401523Χ10-60.11910 625
300299.43 61/2.5022.50 827485023Χ10-60.09650 710
400400.14 61/2.8926.00 1105619023Χ10-60.07221 855
500499.83 61/3.2329.10 1381760023Χ10-60.05781 990
625626.20 91/2.9632.60 1733969023Χ10-60.04625 1140
800802.10 91/3.3536.80 22191205523Χ10-60.03611 1340
1000999.71 91/3.7441.10 27661484523Χ10-60.02897 1540

 

Code NameNominal Aluminum Area Stranding and Wire Diameter Sectional Area Approximate Overall Diameter Linear Mass Calculated D.C. Resistance at 20℃ Calculated Breaking Load Final Modulus of elasticity Coefficient Linear expansion 
mm2mmmm2mmkg/kmΩ/kmdaNhBar/℃
Midge227/2.0623.33 6.18 63.7 1.2270 399590023Χ10-6
Aphis257/3.3526.40 7.20 168.4 1.0810 411590023Χ10-6
Gnat257/2.2126.80 6.60 73.3 1.0660 459590023Χ10-6
Weevil 307/2.4031.60 7.20 86.5 0.9082 486590023Χ10-6 
Mosquito 357/2.5937.00 7.80 100.7 0.7762 603590023Χ10-6 
Ladybird407/2.7942.80 8.40 116.8 0.6689 687590023Χ10-6
Ant507/3.1052.83 9.30 144.2 0.5419 828590023Χ10-6 
Fly607/3.4063.55 10.20 173.5 0.4505 990590023Χ10-6 
Bluebottle707/3.6673.70 11.00 201.1 0.3881 1134590023Χ10-6
Earwig 757/3.7878.50 11.40 214.5 0.3644 1194590023Χ10-6
Grasshopper 807/3.91 84.10 11.70 229.5 0.3406 1278590023Χ10-6 
Clegg907/4.1795.60 12.50 261.0 0.2994 1453590023Χ10-6
Wasp1007/4.39 106.00 13.17 289.3 0.2702 1600590023Χ10-6 
Beetle10019/2.67106.00 13.40 290.4 0.2704 1742560023Χ10-6 
Bee1257/4.90132.00 14.70 360.4 0.2169 1994590023Χ10-6 
Cricket1507/5.36 157.90 16.10 431.2 0.1818 2385590023Χ10-6 
Hornet15019/3.25 157.60 16.25 425.0 0.1825 2570560023Χ10-6 
Caterpillar17519/3.53186.00 17.70 507.6 0.1547 2863560023Χ10-6 
Chafer20019/3.78 213.20 18.90 582.1 0.1349 3240560023Χ10-6
Spider22519/3.99 236.90 20.00 648.6 0.1211 3601560023Χ10-6 
Cockroach25019/4.22265.70 21.10 725.5 0.1083 4040560023Χ10-6
Butterfly30019/4.65 322.70 23.25 880.9 0.0892 4875560023Χ10-6
Moth35019/5.00 373.20 25.00 1018.5 0.0771 5637560023Χ10-6 
Drone35037/3.58373.30 25.10 1016.8 0.0774 5745560023Χ10-6 
Locust40019/5.36 428.50 26.80 1170.4 0.0671 6473560023Χ10-6 
Centipede40037/3.78 415.20 26.46 1133.6 0.0694 6310560023Χ10-6 
Maybug45037/4.09486.90 28.60 1327.1 0.0593 7401560023Χ10-6
Scorpion50037/4.27 529.50 29.90 1446.5 0.0544 7998560023Χ10-6
Cicada60037/4.65 628.60 32.60 1715.4 0.0459 9495560023Χ10-6 
Tarantula75037/5.23794.60 36.60 2170.0 0.0363 12010560023Χ10-6

 

Code NameNominal Aluminum Area Stranding and Wire Diameter Sectional Area Approximate Overall Diameter Linear Mass Calculated D.C. Resistance at 20℃ Calculated Breaking Load Final Modulus of elasticity Coefficient Linear expansion 
mm2mmmm2mmkg/kmΩ/kmdaNhBar/℃
Midge227/2.0623.33 6.18 63.7 1.2270 399590023Χ10-6
Aphis257/3.3526.40 7.20 168.4 1.0810 411590023Χ10-6
Gnat257/2.2126.80 6.60 73.3 1.0660 459590023Χ10-6
Weevil 307/2.4031.60 7.20 86.5 0.9082 486590023Χ10-6 
Mosquito 357/2.5937.00 7.80 100.7 0.7762 603590023Χ10-6 
Ladybird407/2.7942.80 8.40 116.8 0.6689 687590023Χ10-6
Ant507/3.1052.83 9.30 144.2 0.5419 828590023Χ10-6 
Fly607/3.4063.55 10.20 173.5 0.4505 990590023Χ10-6 
Bluebottle707/3.6673.70 11.00 201.1 0.3881 1134590023Χ10-6
Earwig 757/3.7878.50 11.40 214.5 0.3644 1194590023Χ10-6
Grasshopper 807/3.91 84.10 11.70 229.5 0.3406 1278590023Χ10-6 
Clegg907/4.1795.60 12.50 261.0 0.2994 1453590023Χ10-6
Wasp1007/4.39 106.00 13.17 289.3 0.2702 1600590023Χ10-6 
Beetle10019/2.67106.00 13.40 290.4 0.2704 1742560023Χ10-6 
Bee1257/4.90132.00 14.70 360.4 0.2169 1994590023Χ10-6 
Cricket1507/5.36 157.90 16.10 431.2 0.1818 2385590023Χ10-6 
Hornet15019/3.25 157.60 16.25 425.0 0.1825 2570560023Χ10-6 
Caterpillar17519/3.53186.00 17.70 507.6 0.1547 2863560023Χ10-6 
Chafer20019/3.78 213.20 18.90 582.1 0.1349 3240560023Χ10-6
Spider22519/3.99 236.90 20.00 648.6 0.1211 3601560023Χ10-6 
Cockroach25019/4.22265.70 21.10 725.5 0.1083 4040560023Χ10-6
Butterfly30019/4.65 322.70 23.25 880.9 0.0892 4875560023Χ10-6
Moth35019/5.00 373.20 25.00 1018.5 0.0771 5637560023Χ10-6 
Drone35037/3.58373.30 25.10 1016.8 0.0774 5745560023Χ10-6 
Locust40019/5.36 428.50 26.80 1170.4 0.0671 6473560023Χ10-6 
Centipede40037/3.78 415.20 26.46 1133.6 0.0694 6310560023Χ10-6 
Maybug45037/4.09486.90 28.60 1327.1 0.0593 7401560023Χ10-6
Scorpion50037/4.27 529.50 29.90 1446.5 0.0544 7998560023Χ10-6
Cicada60037/4.65 628.60 32.60 1715.4 0.0459 9495560023Χ10-6 
Tarantula75037/5.23794.60 36.60 2170.0 0.0363 12010560023Χ10-6
Code NameNominal Aluminum Area Stranding and wire diameterApproximate Overall DiameterLinear MassNominal breaking LoadCoefficient Linear expansion Maximum Resistance at 20℃ 
mm2mmmmKg/kmKN1/°CΩ/km
Leo34.36 7/2.57.50 94.3 5.7123Χ10-60.8330 
Leonids41.58 7/2.758.25 113 6.7223Χ10-60.6890 
Libra49.48 7/3.009.00 135 7.9823Χ10-60.5790 
Mars77.28 7/3.7511.30 211 11.823Χ10-60.3700 
Mereury111.3 7/4.5013.50 304 16.923Χ10-60.2580 
Moon124.0 7/4.7514.30 339 18.923Χ10-60.2320 
Neptune157.6 19/3.2516.30 433 24.723Χ10-60.1830 
Orion182.8 19/3.517.50 503 28.723Χ10-60.1570 
Pluto209.8 19/3.7518.80 576 31.923Χ10-60.1370 
Saturn261.6 37/3.0021.00 721 42.223Χ10-60.1100 
Sirius307.0 37/3.2522.80 845 48.223Χ10-60.0940 
Taurus336.7 19/4.7523.80 924 51.323Χ10-60.0857 
Triton408.5 37/3.7526.30 1120 62.223Χ10-60.0706 
Uranus506.1 61/3.2529.30 1400 75.223Χ10-60.0572 
Ursula586.9 61/3.531.30 1620 87.323Χ10-60.0493 
Venus673.4 61/3.7533.80 1860 97.223Χ10-60.0429 

 

Code NumberArea mm2Number of wiresDiameterLinearMass kg/kmRated Strength kNCoefficient Linear expansion
1/°C 
D.C Resistance Ω/km
Wire mmConductor mm
101071.35 4.05 27.4 1.95 23Χ10-62.8633 
161671.71 5.12 43.8 3.04 23Χ10-61.7896 
252572.13 6.40 68.4 4.50 23Χ10-61.1453 
404072.70 8.09 109.4 6.80 23Χ10-60.7158 
636373.39 10.20 172.3 10.39 23Χ10-60.4545 
100100192.59 12.90 274.8 17.00 23Χ10-60.2877 
125125192.89 14.50 343.6 21.25 23Χ10-60.2302 
160160193.27 16.40 439.8 26.40 23Χ10-60.1798 
200200193.66 18.30 549.7 32.00 23Χ10-60.1439 
250250194.09 20.50 687.1 40.00 23Χ10-60.1151 
315315373.29 23.00 867.9 51.97 23Χ10-60.0916 
400400373.71 26.00 1102.0 64.00 23Χ10-60.0721 
450450373.94 27.50 1239.8 72.00 23Χ10-60.0641 
600500374.15 29.00 1377.6 80.00 23Χ10-60.0577 
560560374.39 30.70 1542.9 89.60 23Χ10-60.0515 
630630613.63 32.60 1738.3 100.80 23Χ10-60.0458 
710710613.85 34.60 1959.1 113.60 23Χ10-60.0407 
800800614.09 36.80 2207.4 128.00 23Χ10-60.0361 
900900614.33 39.00 2483.3 144.00 23Χ10-60.0321 
10001000614.57 41.10 2759.2 160.00 23Χ10-60.0289 
11201120913.96 43.50 3093.5 179.20 23Χ10-60.0258 
12501250914.18 46.00 3452.6 200.00 23Χ10-60.0231 
14001400914.43 48.70 3866.9 224.00 23Χ10-60.0207 
15001500914.58 50.40 4143.1 240.00 23Χ10-60.0193 

 

PDF Download