PE and XLPE Insulated Overhead Bundled Cables

Home > Products > Aerial Bunch Cable > PE and XLPE Insulated Overhead Bundled Cables

PE and XLPE Insulated Overhead Bundled Cables

PE and XLPE aerial cables designed for harsh outdoor environments.

Insulated bundled conductors with excellent mechanical strength.

Ideal for overhead distribution where space and safety matter.

UV-resistant and insulated for long-lasting power reliability.

PE/XLPE insulated bundled cables – low maintenance, high performance.

Application

PE and XLPE Insulated Overhead Bundled Cables are advanced low- and medium-voltage aerial distribution cables designed for improved safety, reliability, and resistance to harsh environments. These cables consist of aluminum or aluminum alloy conductors, tightly bundled and insulated with either polyethylene (PE) or cross-linked polyethylene (XLPE).

PE insulation offers good mechanical strength, flexibility, and water resistance, making it suitable for moderate climates and standard utility applications. XLPE insulation, on the other hand, provides superior thermal performance, dielectric strength, and aging resistance, enabling continuous operation at 90°C and short-circuit conditions up to 250°C, ideal for hotter climates or heavy-load conditions.

These overhead bundled cables are widely used in urban grids, rural electrification, and forested or coastal areas, where space constraints, vegetation contact, and safety are major concerns. Their compact and insulated design allows for reduced pole spacing, easier installation, and lower maintenance compared to bare conductor systems.

Manufactured to comply with IEC 60502, BS 7870, AS/NZS 3560.1, and other international standards, PE and XLPE insulated bundled cables are a cost-effective, durable, and safe solution for modern overhead power distribution networks.

Specifications

StandardConstruction & Material DetailsTypical Applications & Regional Context
AS/NZS 3560.1LV bundled conductor cable (0.6/1 kV)- Conductors: 1350-H19 aluminum, circular stranded- Insulation: UV-stabilized XLPE– Twisted cores with insulated neutral or bare messenger– Used extensively in Australian rural/urban networks– Optimized for bushfire zones & vegetation-rich areas
AS/NZS 3599.1 / 3599.2MV aerial cable (6.35/11 kV, 12.7/22 kV, 19/33 kV)- XLPE-insulated, screened, water-tree retardant- Semi-conductive conductor shield, copper wire/tape screen, optional HDPE outer sheath– Standard for MV overhead reticulation across New Zealand & Australia– Often used where underground cabling is impractical
IEC 60502 (Part 1 & 2)– International framework for LV and MV power cables– Supports PE or XLPE insulation, optional HDPE sheathing- Allows design flexibility in core configuration and screening– Global utility projects, often adapted into national ABC specifications in Africa, Asia, Latin America
BS 7870-5LV aerial cable (0.6/1 kV)– Conductors: Aluminum, compacted or circular stranded- Insulation: XLPE to BS EN 50397– Self-supporting or catenary neutral types– Used in UK-style suburban overhead networks, often for municipal power upgrades or pole-to-building drops
ParameterPE (Polyethylene)XLPE (Cross-linked Polyethylene)
TypeThermoplastic – softens under heatThermoset – maintains form under high temperature
Thermal PerformanceOperating temp: 70–75°CMax short-circuit: ~130°COperating temp: 90°CShort-circuit: 250°C
UV ResistanceModerate – enhanced with additives like carbon blackExcellent – inherently UV-resistant, preferred for long-term outdoor use
Electrical StrengthModerate dielectric strength (~22–30 kV/mm)Higher dielectric strength (~30–45 kV/mm), excellent resistance to water treeing
Mechanical BehaviorFlexible, good elongation, but less abrasion-resistantTougher, stiffer, more resistant to deformation and mechanical stress
Cost EfficiencyLower material costSlightly higher cost, but longer lifespan and greater stability
Flame ResistanceLow – unless modifiedHigh – compliant with fire-rated cable standards, ideal for bushfire-prone zones

Parameter

AL/XLPE INSULATED AERIAL BUNDLED CABLES  AS/NZS 3560.1 0.6/1 (1.2) kV
Phase conductor         
Nominal cross-sectional areamm21625355095253550
Number of cores 11111222
Minimum number of wires 666615666
Nominal insulation thicknessmm1.31.31.31.51.71.31.31.5
Diameter of insulated coremm7.58.89.811.415.38.89.811.4
Max. dc resistance at 20°Cohm/km1.911.20.8680.6410.321.20.8680.641
Current rating for typical AustralianA7810512515023097120140
installation conditions Conductor temperature = 80°C
Neutral conductor         
Nominal cross-sectional areamm21625355095253550
Minimum number of wires 666615666
Nominal insulation thicknessmm1.31.31.31.51.71.31.31.5
Diameter of insulated coremm7.58.89.811.415.38.89.811.4
Max. dc resistance at 20°Cohm/km1.911.20.8680.6410.321.20.8680.641
Completed cable         
Minimum breaking loadkN4.479.81426.610.514.721
Approx. overall diametermm1517.619.622.830.61921.124.6
Approx. weight of cablekg/km140210270370680310410550
Packing lengthm/drum1000100010001000500100010001000
Phase conductor         
Nominal cross-sectional areamm2162535507095120150
Number of cores 33333333
Minimum number of wires 666612151515
Nominal insulation thicknessmm1.31.31.31.51.51.71.71.7
Diameter of insulated coremm7.58.89.811.413.215.316.818.2
Max. dc resistance at 20°Cohm/km1.911.20.8680.6410.4430.320.2530.206
Current rating for typical Australian installationA7497120140175215250280
conditions Conductor temperature = 80°C
Neutral conductor         
Nominal cross-sectional areamm2162535507095120150
Minimum number of wires 666612151515
Nominal insulation thicknessmm1.31.31.31.51.51.71.71.7
Diameter of insulated coremm7.58.89.811.413.215.316.818.2
Max. dc resistance at 20°Cohm/km1.911.20.8680.6410.4430.320.2530.206
Completed cable         
Minimum breaking loadkN8.81419.62839.253.267.284
Approx. overall diametermm18.121.223.727.531.936.940.643.9
Approx. weight of cablekg/km2904105507401000137016902020
Packing lengthm/drum10001000100010001000500500500

 

AL/XLPE/SCW/HDPE AERIAL BUNDLED CABLES AS/NZS 3599.1 (Light Duty Screen) 6.35/11 (12) kV
Phase conductor
Nominal cross-sectional areamm23535507095120150l85
Number of cores 33333333
Minimum number of wires 6661215l8l830
Nominal diameter of conductormm778.l9.7l4.512.9l4.316.1
Minimum thickness of conductor screenmm0.30.30.30.30.30.30.30.3
Nominal thickness of XLPE insulationmm3.43.43.43.43.43.43.43.4
Minimum thickness of insulation screenmm0.60.60.60.60.60.60.60.6
No. and diameter of metallic screening approx. of copper wireno./mm24/0.8524/0.8524/0.8524/0.8524/0.8524/0.8524/0.8524/0.85
Nominal thickness of outer sheathmm1.81.81.81.81.81.81.81.9
Nominal diameter over sheathingmm24.224.225.126.728.429.931.333.2
Max. dc resistance at 20°Cohm/km0.8680.8680.6410.4430.320.2530.2060.164
Current rating at Ambient temperature = 30°CA185185210260315365415475
Ambient temperature = 40°C Solar radiation = IOOOw/m2 Wind speed = lm/sA155155l85230280325370425
Earth fault current carrying capacity of metallic screen at -1 second ( 1 core )kA22222222
Messenger Galvanized steel wire
StrandingNo./mm7/2.019/2.0l9/2.0l9/2.0l9/2.0l9/2.0l9/2.0l9/2.0
Direction of the outermost layerRighthand (Z)        
Overall diametermm610101010101010
Completed cable
Approx. overall diametermm54.458.460.163.466.869.872.676.4
Approx. weight of cablekg/kml8902190232026102960326035904060
Packing lengthm/drum500500500500500500250250

 

AL/XLPE/SCW/HDPE AERIAL BUNDLED CABLES AS/NZS 3599.1 (Heavy Duty Screen) 6.35/11 (12) kV
Phase conductor
Nominal cross.sectional areamm23535507095120150l85
Number of cores 33333333
Minimum number of wires 6661215l8l830
Nominal diameter of conductormm778.l9.711.512.9l4.316.1
Minimum thickness of conductor screenmm0.30.30.30.30.30.30.30.3
Nominal thickness of XLPE insulationmm3.43.43.43.43.43.43.43.4
Minimum thickness of insulation screenmm0.60.60.60.60.60.60.60.6
No. and diameter of metallic screening approx. of copper wireno./mm40/0.8540/0.8523/l.3532/l.3538/l.3538/l.3538/l.3538/l.35
Nominal thickness of outer sheathmml.8l.8l.8l.8l.8l.8l.81.9
Nominal diameter over sheathingmm24.224.226.127.729.430.932.334.2
Max. dc resistance at 20°Cohm/km0.8680.8680.64l0.4430.320.2530.2060.l64
Current rating at Ambient temperature = 30°CAl85l852102603153654l5475
Ambient temperature = 40°C Solar radiation = I000w/m2 Wind speed = lm/sA155155l85230280325370425
Earth fault current carrying capacity of metallic screen at -1 second ( 1 Core )kA3.3 *3.3 *4.8*6.8*8888
Messenger Galvanized steel wire
StrandingNo./mm7/2.0l9/2.0l9/2.0l9/2.0l9/2.0l9/2.0l9/2.0l9/2.0
Direction of the outermost layerRight-hand (Z)        
Overall diametermm610101010101010
Completed cable
Approx. overall diametermm54.458.462.165.468.87l.874.678.4
Approx. weight of cablekg/km21502440288035404l30444047705240
Packing lengthm/drum500500500500500500250250
AL/XLPE/SCW/HDPE AERIAL BUNDLED CABLES AS/NZS 3599.1 (Light Duty Screen) 12.7/22 (24) kV
Phase conductor
Nominal cross-sectional areamm23535507095120150l85
Number of cores 33333333
Minimum number of wires 6661215l8l830
Nominal diameter of conductormm778.l9.711.512.9l4.316.1
Minimum thickness of conductor screenmm0.30.30.30.30.30.30.30.3
Nominal thickness of XLPE insulationmm5.55.55.55.55.55.55.55.5
Minimum thickness of insulation screenmm0.60.60.60.60.60.60.60.6
No. and diameter of metallic screening approx. of copper wireno./mm24/0.8524/0.8524/0.8524/0.8524/0.8524/0.8524/0.8524/0.85
Nominal thickness of outer sheathmm1.81.81.81.81.91.922
Nominal diameter over sheathingmm28.428.429.330.932.834.335.937.6
Max. dc resistance at 20°Cohm/km0.8680.8680.6410.4430.320.2530.2060.164
Current rating at Ambient temperature = 30°CA1701702052603153604l0470
Ambient temperature = 40°C Solar radiation = IOOOw/m2 Wind speed = lm/sA150150l852302803203654l5
Earth fault current carrying capacity of metallic screen at -1 second ( 1 Core )kA22222222
Messenger Galvanized steel wire
StrandingNo./mm7/2.019/2.0l9/2.0l9/2.0l9/2.0l9/2.0l9/2.0l9/2.0
Direction of the outermost layerRighthand (Z)        
Overall diametermm610101010101010
Completed cable
Approx. overall diametermm62.866.868.57l.875.678.68l.885.2
Approx. weight of cablekg/km234026402780310035103850424047l0
Packing lengthm/drum500500500250250250250250
AL/XLPE/SCW/HDPE AERIAL BUNDLED CABLES AS/NZS 3599.1 (Heavy Duty Screen) 12.7/22 (24) kV
Phase conductor
Nominal cross.sectional areamm23535507095120150l85
Number of cores 33333333
Minimum number of wires 6661215l8l830
Nominal diameter of conductormm778.l9.711.512.9l4.316.1
Minimum thickness of conductor screenmm0.30.30.30.30.30.30.30.3
Nominal thickness of XLPE insulationmm5.55.55.55.55.55.55.55.5
Minimum thickness of insulation screenmm0.60.60.60.60.60.60.60.6
No. and diameter of metallic screening approx. of copper wireno./mm40/0.8540/0.8523/l.3532/l.3538/l.3538/l.3538/l.3538/l.35
Nominal thickness of outer sheathmml.8l.8l.8l.81.91.922
Nominal diameter over sheathingmm28.428.430.331.933.835.336.938.6
Max. dc resistance at 20°Cohm/km0.8680.8680.64l0.4430.320.2530.2060.l64
Current rating at Ambient temperature = 30°CA1701702052603153604l0470
Ambient temperature = 40°C Solar radiation = I000w/m2 Wind speed = lm/sA1501501852302803203654l5
Earth fault current carrying capacity of metallic screen at -1 second ( 1 Core )kA3.3 *3.3 *4.8*6.8*8888
Messenger Galvanized steel wire
StrandingNo./mm7/2.019/2.019/2.019/2.019/2.019/2.019/2.019/2.0
Direction of the outermost layerRight-hand (Z)        
Overall diametermm610101010101010
Completed cable
Approx. overall diametermm62.866.870.573.877.680.683.887.2
Approx. weight of cablekg/km26002900335040304680502054l05880
Packing lengthm/drum500500500250250250250250
AL/XLPE/SCW/HDPE AERIAL BUNDLED CABLES AS/NZS 3599.1 (Light Duty Screen) 6.35/11 (12) kV
Phase conductor
Nominal cross-sectional areamm23535507095120150l85
Number of cores 33333333
Minimum number of wires 6661215l8l830
Nominal diameter of conductormm778.l9.7l4.512.9l4.316.1
Minimum thickness of conductor screenmm0.30.30.30.30.30.30.30.3
Nominal thickness of XLPE insulationmm3.43.43.43.43.43.43.43.4
Minimum thickness of insulation screenmm0.60.60.60.60.60.60.60.6
No. and diameter of metallic screening approx. of copper wireno./mm24/0.8524/0.8524/0.8524/0.8524/0.8524/0.8524/0.8524/0.85
Nominal thickness of outer sheathmm1.81.81.81.81.81.81.81.9
Nominal diameter over sheathingmm24.224.225.126.728.429.931.333.2
Max. dc resistance at 20°Cohm/km0.8680.8680.6410.4430.320.2530.2060.164
Current rating at Ambient temperature = 30°CA185185210260315365415475
Ambient temperature = 40°C Solar radiation = IOOOw/m2 Wind speed = lm/sA155155l85230280325370425
Earth fault current carrying capacity of metallic screen at -1 second ( 1 core )kA22222222
Messenger Galvanized steel wire
StrandingNo./mm7/2.019/2.0l9/2.0l9/2.0l9/2.0l9/2.0l9/2.0l9/2.0
Direction of the outermost layerRighthand (Z)        
Overall diametermm610101010101010
Completed cable
Approx. overall diametermm54.458.460.163.466.869.872.676.4
Approx. weight of cablekg/kml8902190232026102960326035904060
Packing lengthm/drum500500500500500500250250

 

AL/XLPE/SCW/HDPE AERIAL BUNDLED CABLES AS/NZS 3599.1 (Heavy Duty Screen) 6.35/11 (12) kV
Phase conductor
Nominal cross.sectional areamm23535507095120150l85
Number of cores 33333333
Minimum number of wires 6661215l8l830
Nominal diameter of conductormm778.l9.711.512.9l4.316.1
Minimum thickness of conductor screenmm0.30.30.30.30.30.30.30.3
Nominal thickness of XLPE insulationmm3.43.43.43.43.43.43.43.4
Minimum thickness of insulation screenmm0.60.60.60.60.60.60.60.6
No. and diameter of metallic screening approx. of copper wireno./mm40/0.8540/0.8523/l.3532/l.3538/l.3538/l.3538/l.3538/l.35
Nominal thickness of outer sheathmml.8l.8l.8l.8l.8l.8l.81.9
Nominal diameter over sheathingmm24.224.226.127.729.430.932.334.2
Max. dc resistance at 20°Cohm/km0.8680.8680.64l0.4430.320.2530.2060.l64
Current rating at Ambient temperature = 30°CAl85l852102603153654l5475
Ambient temperature = 40°C Solar radiation = I000w/m2 Wind speed = lm/sA155155l85230280325370425
Earth fault current carrying capacity of metallic screen at -1 second ( 1 Core )kA3.3 *3.3 *4.8*6.8*8888
Messenger Galvanized steel wire
StrandingNo./mm7/2.0l9/2.0l9/2.0l9/2.0l9/2.0l9/2.0l9/2.0l9/2.0
Direction of the outermost layerRight-hand (Z)        
Overall diametermm610101010101010
Completed cable
Approx. overall diametermm54.458.462.165.468.87l.874.678.4
Approx. weight of cablekg/km21502440288035404l30444047705240
Packing lengthm/drum500500500500500500250250
AL/XLPE/SCW/HDPE AERIAL BUNDLED CABLES AS/NZS 3599.1 (Light Duty Screen) 12.7/22 (24) kV
Phase conductor
Nominal cross-sectional areamm23535507095120150l85
Number of cores 33333333
Minimum number of wires 6661215l8l830
Nominal diameter of conductormm778.l9.711.512.9l4.316.1
Minimum thickness of conductor screenmm0.30.30.30.30.30.30.30.3
Nominal thickness of XLPE insulationmm5.55.55.55.55.55.55.55.5
Minimum thickness of insulation screenmm0.60.60.60.60.60.60.60.6
No. and diameter of metallic screening approx. of copper wireno./mm24/0.8524/0.8524/0.8524/0.8524/0.8524/0.8524/0.8524/0.85
Nominal thickness of outer sheathmm1.81.81.81.81.91.922
Nominal diameter over sheathingmm28.428.429.330.932.834.335.937.6
Max. dc resistance at 20°Cohm/km0.8680.8680.6410.4430.320.2530.2060.164
Current rating at Ambient temperature = 30°CA1701702052603153604l0470
Ambient temperature = 40°C Solar radiation = IOOOw/m2 Wind speed = lm/sA150150l852302803203654l5
Earth fault current carrying capacity of metallic screen at -1 second ( 1 Core )kA22222222
Messenger Galvanized steel wire
StrandingNo./mm7/2.019/2.0l9/2.0l9/2.0l9/2.0l9/2.0l9/2.0l9/2.0
Direction of the outermost layerRighthand (Z)        
Overall diametermm610101010101010
Completed cable
Approx. overall diametermm62.866.868.57l.875.678.68l.885.2
Approx. weight of cablekg/km234026402780310035103850424047l0
Packing lengthm/drum500500500250250250250250
AL/XLPE/SCW/HDPE AERIAL BUNDLED CABLES AS/NZS 3599.1 (Heavy Duty Screen) 12.7/22 (24) kV
Phase conductor
Nominal cross.sectional areamm23535507095120150l85
Number of cores 33333333
Minimum number of wires 6661215l8l830
Nominal diameter of conductormm778.l9.711.512.9l4.316.1
Minimum thickness of conductor screenmm0.30.30.30.30.30.30.30.3
Nominal thickness of XLPE insulationmm5.55.55.55.55.55.55.55.5
Minimum thickness of insulation screenmm0.60.60.60.60.60.60.60.6
No. and diameter of metallic screening approx. of copper wireno./mm40/0.8540/0.8523/l.3532/l.3538/l.3538/l.3538/l.3538/l.35
Nominal thickness of outer sheathmml.8l.8l.8l.81.91.922
Nominal diameter over sheathingmm28.428.430.331.933.835.336.938.6
Max. dc resistance at 20°Cohm/km0.8680.8680.64l0.4430.320.2530.2060.l64
Current rating at Ambient temperature = 30°CA1701702052603153604l0470
Ambient temperature = 40°C Solar radiation = I000w/m2 Wind speed = lm/sA1501501852302803203654l5
Earth fault current carrying capacity of metallic screen at -1 second ( 1 Core )kA3.3 *3.3 *4.8*6.8*8888
Messenger Galvanized steel wire
StrandingNo./mm7/2.019/2.019/2.019/2.019/2.019/2.019/2.019/2.0
Direction of the outermost layerRight-hand (Z)        
Overall diametermm610101010101010
Completed cable
Approx. overall diametermm62.866.870.573.877.680.683.887.2
Approx. weight of cablekg/km26002900335040304680502054l05880
Packing lengthm/drum500500500250250250250250
 IEC 60502 & TNB Specifcation(0.6/1 (1.2) kV)Cables without street lighting
Phase conductor
Nominal cross-sectional areamm216 *16 *2535507095120150l85
Number of cores 1333333333
Minimum number of wires 666661215153030
Nominal insulation thicknessmm111.21.2l.4l.41.61.6l.82
Diameter of insulated coremm6.86.88.59.511.21315.116.6l8.420.6
Max. dc resistance at 20°Cohm/km1.911.911.20.8680.64l0.4430.320.2530.2060.l64
Current rating at still wind, ambient temperature =30°C, conductor temperature = 75°CA616184l04129167209246283332
Maximum voltage dropmV/A/m4.674.052.54l.841.360.950.690.550.460.37
Messenger conductor
Nominal cross-sectional areamm2252525253550707095120
Minimum number of wires 66666612121515
Nominal insulation thicknessmm1.21.21.21.21.2l.4l.4l.41.61.6
Diameter of insulated coremm8.58.58.58.59.511.213.113.115.116.6
Max. dc resistance at 20°Cohm/km1.3121.3121.3121.3120.9430.6930.4690.4690.3490.273
Calculated breaking loadkN6.46.46.46.48.912.1l8.0l8.024.230.8
Completed cable
Approx. overall diametermm15.31923.225.63034.940.644.l49.254.9
Approx. weight of cablekg/km16029040050068092012701510l,8702340
Packing lengthm/drum100010001000100010001000500500500500
IEC 60502 & TNB Specifcation(0.6/1 (1.2) kV)Cables with street lighting
Phase conductor
Nominal cross-sectional areamm22535507095 *120150185*
Number of cores 33333333
Minimum number of wires 6661215153030
Nominal insulation thicknessmm1.21.2l.4l.41.61.61.82
Diameter of insulated coremm8.59.511.21315.116.618.420.6
Max. dc resistance at 20°Cohm/km1.20.8680.6410.4430.320.2530.2060.164
Current rating at still wind, ambient temperature = 30°C, conductor temperature = 75°CA84104129167209246283332
Maximum voltage dropmV/A/m2.541.841.360.950.690.550.460.37
Messenger conductor
Nominal cross-sectional areamm225253550707095120
Minimum number of wires 666612121515
Nominal insulation thicknessmm1.21.21.2l.4l.4l.41.61.6
Diameter of insulated coremm8.58.59.511.213.113.115.116.6
Max. dc resistance at 20°Cohm/km1.3121.3120.9430.6930.4690.4690.3490.273
Calculated breaking loadkN6.46.48.912.1l8.0l8.024.230.8
Street lighting conductor
Nominal cross-sectional areamm21616161616161616
Minimum number of wires 66666666
Nominal insulation thicknessmm11111111
Diameter of insulated coremm6.86.86.86.86.86.86.86.8
Max. dc resistance at 20°Cohm/km1.911.911.911.911.911.911.911.91
Completed cable
Approx. overall diametermm23.225.63034.940.644.l49.254.9
Approx. weight of cablekg/km4705607409801330l,580l,9402,4l0
Packing lengthm/drum1000100010001000500500500500
AERIAL BUNDLED CABLES AL/XLPE/SCT/PVC CABLES IEC 60502 & TNB Specifcation 6.35/11 (12) kV 
Phase conductor
Nominal cross-sectional areamm2507095120150l85240
Number of cores 3333333
Minimum number of wires 6121515153030
Nominal diameter of conductormm8.l9.711.512.9l4.316.1l8.4
Nominal thickness of XLPE insulationmm3.43.43.43.43.43.43.4
Metallic screening approx. thickness of copper tapemm0.20.20.20.20.20.20.2
Nominal thickness of outer sheathmm2.32.32.32.32.32.32.3
Nominal diameter over sheathingmm2324.626.327.829.230.933.3
Max. dc resistance at 20°Cohm/km0.64l0.4430.320.2530.2060.l640.125
Earth fault current carrying capacity of metallic screen at
-1 second ( 1 Core )kA1.571.721.882.012.l42.32.52
-3 seconds ( 1 Core )kA0.90.99l.081.161.231.33l.45
Messenger – Galvanized steel wire
Nominal cross-sectional areamm250505050505050
StrandingNo./mm7/3.l57/3.l57/3.l57/3.l57/3.l57/3.l57/3.l5
Direction of the outermost layer Righthand (Z)
Overall diametermm9.459.459.459.459.459.459.45
Minimum breaking loadkg6270627062706270627062706270
Completed cable
Approx. overall diametermm55596265677175
Approx. weight of cablekg/km2540289033003660404045405290
Packing lengthm/drum500500500500500500500
AERIAL BUNDLED CABLES AL/XLPE/SCT/PVC CABLES IEC 60502 & TNB Specifcation 12.7/22 (24) kV
Phase conductor
Nominal cross.sectional areamm2507095120150l85240
Number of cores 3333333
Minimum number of wires 6121515153030
Nominal diameter of conductormm8.l9.711.512.9l4.316.1l8.4
Nominal thickness of XLPE insulationmm5.55.55.55.55.55.55.5
Metallic screening approx. thickness of copper tapemm0.20.20.20.20.20.20.2
Nominal thickness of outer sheathmm2.32.32.32.32.32.32.3
Nominal diameter over sheathingmm27.228.830.53233.435.137.5
Max. dc resistance at 20°Cohm/km0.64l0.4430.320.2530.2060.l640.125
Earth fault current carrying capacity of metallic screen at
-1 second ( 1 Core )kA1.962.112.262.42.532.682.9
-3 seconds ( 1 Core )kA1.131.211.31l.38l.461.551.67
Messenger Galvanized steel wire        
Nominal cross-sectional areamm250505050505050
StrandingNo./mm7/3.l57/3.l57/3.l57/3.l57/3.l57/3.l57/3.l5
Direction of the outermost layer Right-hand (Z)
Overall diametermm9.459.459.459.459.459.459.45
Minimum breaking loadkg6270627062706270627062706270
Completed cable
Approx. overall diametermm64677073757883
Approx. weight of cablekg/km3150354039804360477053006100
Packing lengthm/drum500500500500500250250
AERIAL BUNDLED CABLES AL/XLPE/SCT/PVC CABLES IEC 60502 & TNB Specifcation 19/33 (36) kV
Phase conductor
Nominal cross-sectional areamm2507095120150l85240
Number of cores 3333333
Minimum number of wires 6121515153030
Nominal diameter of conductormm8.l9.711.512.9l4.316.1l8.4
Nominal thickness of XLPE insulationmm8888888
Metallic screening approx. thickness of copper tapemm0.20.20.20.20.20.20.2
Nominal thickness of outer sheathmm2.32.32.32.32.32.32.3
Nominal diameter over sheathingmm32.233.835.53738.440.l42.5
Max. dc resistance at 20°Cohm/km0.64l0.4430.320.2530.2060.l640.125
Earth fault current carrying capacity of metallic screen at
-1 second ( 1 Core )kA2.4l2.562.722.862.993.l43.36
-3 seconds ( 1 Core )kA1.39l.481.571.651.72l.8ll.94
Messenger Galvanized steel wire
Nominal cross.sectional areamm250505050505050
StrandingNo./mm7/3.l57/3.l57/3.l57/3.l57/3.l57/3.l57/3.l5
Direction of the outermost layerRighthand (Z)       
Overall diametermm9.459.459.459.459.459.459.45
Minimum breaking loadkg6270627062706270627062706270
Completed cable
Approx. overall diametermm73767982848791
Approx. weight of cablekg/km3980440048805300574063107160
Packing lengthm/drum500500500250250250250
IEC 60502 & DES/LV/ABC 0.6/1 (1.2) kV Cables without street lighting
Phase conductor
Nominal cross-sectional areamm22535
Number of cores 33
Minimum number of wires 66
Nominal insulation thicknessmml.4l.4
Diameter of insulated coremm8.99.9
Max. dc resistance at 20°Cohm/km1.20.868
Minimum breaking loadkN3.54.9
Current rating at still wind, ambient temperature = 30°C, conductor temperature = 75°CA84104
Neutral Conductor
Nominal cross-sectional areamm22535
Minimum number of wires 66
Nominal insulation thicknessmml.4l.4
Diameter of insulated coremm8.99.9
Max. dc resistance at 20°Cohm/km1.20.868
Minimum breaking loadkN3.54.9
Completed cable
Approx. overall diametermm21.523.9
Approx. weight of cablekg/km420550
Packing lengthm/drum10001000
IEC 60502 & DES/LV/ABC 0.6/1 (1.2) kV Cables with street lighting
Phase conductor
Nominal cross-sectional areamm2120l85
Number of cores 33
Minimum number of wires 1530
Nominal insulation thicknessmm1.72.2
Diameter of insulated coremm1721
Max. dc resistance at 20°Cohm/km0.2530.164
Minimum breaking loadkN16.825.9
Current rating at still wind, ambient temperature = 30°C, conductor temperature = 75°CA246332
Neutral conductor
Nominal cross-sectional areamm2120185
Minimum number of wires 1530
Nominal insulation thicknessmm1.72.2
Diameter of insulated coremm1721
Max. dc resistance at 20°Cohm/km0.2530.l64
Minimum breaking loadkNl6.825.9
Street lighting conductor
Nominal cross-sectional areamm22525
Minimum number of wires 66
Nominal insulation thicknessmm1.41.4
Diameter of insulated coremm8.98.9
Max. dc resistance at 20°Cohm/km1.21.2
Completed cable
Approx. overall diametermm43.850.7
Approx. weight of cablekg/km1,8002700
Packing lengthm/drum500500
BS 7870-5 0.6/1 (1.2) kV Cables without street lighting Cables with street lighting
Phase conductor
Nominal cross-sectional areamm225355070952535507095120
Number of cores 11111333333
Minimum number of wires 6661215666121515
Nominal insulation thicknessmm1.31.31.51.51.71.31.31.51.51.71.7
Diameter of insulated coremm8.89.811.513.215.38.89.811.513.215.316.8
Max. dc resistance at 20°Cohm/km1.20.8680.6410.4430.321.20.8680.6410.4430.320.253
Current rating at still wind ambient temperature = 30°C Conductor temperature = 75°CA8410412916720984104129167209283
Neutral conductor
Nominal cross-sectional areamm225355070952535507095120
Minimum number of wires 6661215666121515
Nominal insulation thicknessmm1.31.31.51.51.71.31.31.51.51.71.7
Diameter of insulated coremm8.89.811.513.215.38.89.811.513.215.316.8
Max. dc resistance at 20°Cohm/km1.20.8680.6410.4430.321.20.8680.6410.4430.320.253
Completed cable
Minimum breaking loadkN8.211.215.22230.6l6.422.430.44461.277.6
Approx. overall diametermm17.619.62326.430.621.223.727.831.936.940.6
Approx. weight of cablekg/km2102703605006804l0550730100013701690
Packing lengthm/drum10001000100010005001000100010001000500500
BS 7870-5 0.6/1 (1.2) kV Cables without street lighting Cables with street lighting
Phase conductor
Nominal cross-sectional areamm2507095
Number of cores 333
Minimum number of wires 61215
Nominal insulation thicknessmm1.51.51.7
Diameter of insulated coremm11.513.215.3
Max. dc resistance at 20°Cohm/km0.6410.4430.32
Current rating at still wind, ambientA129167209
temperature = 30°C conductor temperature = 75°C
Neutral conductor
Nominal cross-sectional areamm2507095
Minimum number of wires 61215
Nominal insulation thicknessmm1.51.51.7
Diameter of insulated coremm11.511.515.3
Max. dc resistance at 20°Cohm/km0.6410.4430.32
Street lighting conductor
Nominal cross-sectional areamm2252525
Minimum number of wires 666
Nominal insulation thicknessmm1.31.31.3
Diameter of insulated coremm8.88.88.8
Max. dc resistance at 20°Cohm/km1.21.21.2
Completed cable
Minimum breaking loadkN34.548.165.3
Approx. overall diametermm29.833.638.2
Approx. weight of cablekg/km8301100l470
Packing lengthm/drum10001000500

PDF Download

PDF Download

WHY CHOOSE US

INOUIRY NOW

CONTACT US

24-hour online service

Own factory processing

PRODUCT CATEGORY

HOT-SALE PRODUCT

0.6/1kV ABC cable built to GB/T 12527 standard…

Preassembled overhead cable bundles for fast….

Factory-supplied LV/MV ABC cable – IEC, BS, NFC …

CONTACT USIMMEDIATELY