HTA CIS Underground Twisted Pair Cable NFC 33-226

Home > Products > Aerial Bunch Cable > HTA CIS Underground Twisted Pair Cable NFC 33-226

HTA CIS Underground Twisted Pair Cable NFC 33-226

HTA CIS twisted pair cable for reliable underground transmission.

NFC-compliant cable with UV and moisture-resistant jacket.

Perfect for underground MV control and signaling systems.

Durable twisted pair cable designed for harsh buried conditions.

High-performance HTA CIS cable – stable signal, long service life.

Application

These HTA CIS Underground Twisted Pair NFC 33-226 cables are suitable for medium-voltage public power distribution from 6/10kV to 18/30kV. They are used for power distribution under normal conditions in overhead installations.

The three-phase cables are wound around a messenger consisting of a steel core with a cross-section of 50mm² and an outer insulation with a nominal thickness of 1.2mm. The galvanized steel strands have a minimum breaking load of 64,700N.

Specifications

CategoryTechnical DescriptionTypical Applications
StandardNFC 33-226 – French standard for underground medium-voltage twisted pair cables (CIS: Conducteurs Isolés Souterrains)Used in MV distribution networks in France and French-speaking countries
Cable TypeHTA CIS – Underground twisted pair of XLPE-insulated, screened conductorsSuitable for 11 kV – 33 kV underground installations
Conductor MaterialStranded copper or aluminum, Class 2 (IEC 60228)Ensures high conductivity and flexibility
InsulationHigh-performance XLPE (Cross-linked Polyethylene) – rated for 90°C continuous operationExcellent thermal and dielectric behavior
Twisting ConfigurationTwo single-core insulated cables twisted together (also called “twisted single-core pair”)Improves electromagnetic balance and eases jointing
ScreeningEach core is screened with copper tape or wires, plus semi-conductive layers for field controlReduces EMF, allows safe grounding, and supports fault detection
Outer SheathUV-, water-, and corrosion-resistant HDPE or PVC, depending on installation conditionsSuitable for direct burial in harsh soil environments
Voltage RangeTypically 12/20 kV, 18/30 kV, and 21/35 kVMV underground distribution, substation links
Fire PerformanceAvailable with flame retardant / LSZH sheath on requestFor sensitive urban or tunnel environments
Standards Compliance– NFC 33-226- IEC 60502-2 (reference)- CENELEC HD 620 (partial alignment)Ensures compatibility with ERDF/Enedis and French utility networks
IdentificationCores are color-marked or numbered; cable often comes with traceability marking on sheathHelps in accurate installation & maintenance



Parameter

Medium Voltage Overhead Cables 
No.of cores and nominal cross
section
PhaseMessengerApprox. overall diameterApprox weightMax.DC
resistance
ofconductor
at 20℃
Min.
Number
Ofwires
Nominal insulation thicknessNominal AL/PET tape thicknessNominal
sheath thickness
ConductorNominal insulation thickness
mm²No.mmmmmmNo./mmmmmmkg/kmΩ/km
6/10(12)kV         
3x1x50+1×5063.40.227/3.01.249.919480.641
3x1x70+1×50123.40.227/3.01.253.622390.443
3x1x95+1×50153.40.227/3.01.257.525790.32
3x1x120+1×50153.40.227/3.01.26028590.253
3x1x150+1×50153.40.227/3.01.263.331820.206
3x1x185+1×50303.40.227/3.01.26735990.164
3x1x240+1×50303.40.227/3.01.271.942330.125
3x1x300+1×50303.40.227/3.01.276.748890.1
3x1x400+1×50533.40.22.27/3.01.283.458520.0778
3x1x500+1×50533.40.22.27/3.01.290.969910.0605
3x1x630+1×50533.40.22.47/3.01.299.885050.0469
8.7/16(17.5)kV         
3x1x50+1×5064.50.227/3.01.255.122200.641
3x1x70+1×50124.50.227/3.01.258.825280.443
3x1x95+1×50154.50.227/3.01.262.628880.32
3x1x120+1×50154.50.227/3.01.265.231810.253
3x1x150+1×50154.50.227/3.01.268.535200.206
3x1x185+1×50304.50.227/3.01.272.139560.164
3x1x240+1×50304.50.22.17/3.01.277.546480.125
3x1x300+1×50304.50.22.17/3.01.282.353290.1
3x1x400+1×50534.50.22.27/3.01.288.662920.0778
3x1x500+1×50534.50.22.37/3.01.296.675090.0605
3x1x630+1×50534.50.22.47/3.01.210590270.0469
12/20(24)kV        
3x1x50+1×5065.50.227/3.01.259.824900.641
3x1x70+1×50125.50.227/3.01.263.528160.443
3x1x95+1×50155.50.227/3.01.267.431930.32
3x1x120+1×50155.50.227/3.01.27034990.253
3x1x150+1×50155.50.227/3.01.273.238530.206
3x1x185+1×50305.50.227/3.01.276.943060.164
3x1x240+1×50305.50.22.17/3.01.282.350220.125
3x1x300+1×50305.50.22.27/3.01.287.557630.1
3x1x400+1×50535.50.22.37/3.01.293.767560.0778
3x1x500+1×50535.50.22.47/3.01.2101.780140.0605
3x1x630+1×50535.50.22.57/3.01.2110.295740.0469
18/30(36)kV        
3x1x50+1×50680.227/3.01.270.631770.641
3x1x70+1×501280.227/3.01.274.335400.443
3x1x95+1×501580.22.17/3.01.278.639910.32
3x1x120+1×501580.22.17/3.01.281.243240.253
3x1x150+1×501580.22.27/3.01.284.947480.206
3x1x185+1×503080.22.27/3.01.288.652420.164
3x1x240+1×503080.22.37/3.01.29460180.125
3x1x300+1×503080.22.47/3.01.299.168160.1
3x1x400+1×505380.22.57/3.01.2105.478800.0778
3x1x500+1×505380.22.67/3.01.2113.492240.0605
3x1x630+1×505380.22.77/3.01.2121.8121.80.0469

 