Assembling Insulated Wire Bundles ABC-SANS 1418

Home > Products > Aerial Bunch Cable > Assembling Insulated Wire Bundles ABC-SANS 1418

Assembling Insulated Wire Bundles ABC-SANS 1418

ABC cable assembled to SANS 1418 – safe, compact, and reliable.

Insulated wire bundles ideal for overhead low-voltage networks.

Durable XLPE insulation for African climate conditions.

ABC Cable – Engineered for utility-grade performance.

Preassembled overhead cable bundles for fast, efficient installation.

Application

Assembling insulated wire bundles, also known as Aerial Bundled Cables (ABC), are designed for low-voltage overhead power distribution in compliance with SANS 1418, the South African national standard. These cables offer a safe, efficient, and compact alternative to traditional bare conductor systems, particularly suited to high-density urban, peri-urban, and informal settlement environments.

The standard configuration includes three XLPE-insulated aluminum phase conductors and one bare or insulated neutral messenger, bundled together to form a lightweight, self-supporting unit. Optional public lighting conductors can also be included depending on system design.

Thanks to the full insulation of live conductors, ABC cables minimize the risk of electric shock, phase-to-phase faults, and outages due to vegetation or external contact. The bundled design supports reduced pole spacing, simplified installation, and lower right-of-way requirements—ideal for areas with limited space or safety challenges.

With XLPE insulation rated for 90°C continuous operation, UV and weather resistance, and strong mechanical integrity, these cables ensure long service life, reduced maintenance, and enhanced reliability.

Specifications

CategoryTechnical DescriptionTypical Applications
StandardSANS 1418 – South African National Standard for Low-Voltage Aerial Bundled Cables (typically 0.6/1 kV)Widely used in South Africa, Botswana, Namibia, and other SADC countries for overhead distribution
Cable TypeAssembled Insulated Wire Bundle (ABC)Conductors bundled together and helically twisted around a neutral/messenger wireIdeal for urban electrification, rural grid extension, and municipal street lighting
Voltage Rating0.6/1 kV – for low-voltage distribution networksSuitable for residential feeders, public area grids, informal settlements, and commercial low-voltage supply
Conductor Material1350-H19 stranded aluminum for phase conductors- Alloy or steel-reinforced aluminum (ACSR / AAAC) for neutral/messengerCombines lightweight with high conductivity and strength
InsulationXLPE (Cross-linked Polyethylene)– UV-resistant, weatherproof, flame-retardantEnsures durability in sunny, humid, windy, and dusty African environments
Assembly Configuration3 or 4-core bundle:• 3 × Phase + 1 × Neutral• Optional public lighting core (e.g. 3 × Phase + 1 × Neutral + 1 × Lighting)Enables single-phase, three-phase, or mixed-load distribution from a single compact overhead bundle



Parameter

Type of conductor or coreNominal cross-sectional area mm2Number of wires  mmResistance at 200C
Ω/km
Max
Diamater of conductor
mm
Min
Diamater of conductor mm MaxBreaking force MinThickness of dielectric mm AverageThickness of dielectric mm Min core Outside diameter mm Mincore Outside diameter mm Max
Phase or auxiliary or nonstrain- bearing neutral(aluminium)1661.914.65.120701.20.9877.8
2561.25.86.333001.41.168.69.4
3560.8686.87.345001.61.341010.9
5060.6417.98.462001.61.3411.112
70120.4439.710.289001.81.5213.314.2
95150.321112123001.81.5214.616
120150.25312.513.5156001.81.5216.317.5
150150.20613.915192001.81.5217.118.6
       1.52  
Service connection (aluminium)16         256            61.91   1.2   1.83 1.15 0.7274.65.62070     33001.2     1.40.98      1.167.0         8.68.0        9.6
Service connection (copper)1061.83_4.236001.20.986.27
1561.15_5.357001.20.987.28
2560.727_6.687501.41.168.69.6
Supporting (aluminium)54.67*3.150.639.29.6166001.61.3412.313
707*3.500.51010.4201001.61.3412.913.6

 

AAC Conductor Supported Service Drop Cable- ICEA S-76-474
Code NameSizeAl Phase CoreAAAC ConductorRated StrengthApprox. Overall Dia.Approx. Weight
Cross-section AreaStr. No.Dia.Insulation NominalCross-section AreaStr. No.Dia.
Thickness
AWG/MCMmm2No.smmmmmm2No.smmKNmmkg/km
DUPLEX
Collie1X6+6AWG13.374.651.1413.374.682.511.692
Spaniel1X4+4AWG21.1575.71.1421.1575.883.913.8138.3
Doberman1X2+2AWG33.6277.21.1433.6377.41616.8211.2
Malemute1X1/0+1/0AWG53.5199.21.5253.5179.368.821.6339.9
TRIPLEX
Patella2X6+6AWG13.374.651.1413.374.682.513.3149
Oyster2X4+4AWG21.1575.71.1421.1575.883.915.6221
Clam2X2+2AWG33.6277.21.1433.6377.41618.9334
Murex2X1/0+1/0AWG53.4979.21.5253.5179.368.824.2538
Nassa2X2/0+2/0AWG67.43710.31.5267.44710.511.226.6663
Melita2X3/0+3/0AWG85.011911.61.5285.03711.7914.729.4820
Portunus2X4/0+4/0AWG107.219131.52107.2713.2617.932.51017
Nannynose2X336.4+336.4MCM170.451916.562.03170.461916.927.341.71631
QUADRUPLEX
Pinto3X4+4AWG21.1575.71.1421.1575.883.918302
Mustang3X2+2AWG33.6277.21.1433.6377.41621.6454
Criollo3X1/0+1/0AWG53.51199.21.5253.5179.368.827.8734
Percheron3X2/0+2/0AWG67.441910.31.5267.44710.511.230.4902
Hanoverian3X3/0G+3/0AWG85.031911.61.5285.03711.7914.733.61113
Oldenburg3X4/0+4/0AWG107.219131.52107.2713.2617.9371377
Lippizaner3X336.4+336.4MCM170.461916.562.03170.461916.927.347.52212

 

AAAC Conductor Supported Service Drop Cable- ICEA S-76-474
Code NameSizeAl   Phase CoreAAAC   ConductorRated StrengthApprox.Overall Dia.Approx.Weight
Cross-section AreaStr.Dia.Insulation   NominalCross-section   AreaStranding No.Dia.
No.Thickness
AWG/MCMmm2No.smmmmmm2No.smmKNmmkg/km
Duplex
Chihuahua1X6AWG+6AWG13.314.111.1415.575.044.9311.4396
Vizsla1X6AWG+6AWG13.374.651.1415.575.044.9311.9798
Harrier1X4AWG+4AWG21.1515.191.1424.6776.367.8213.83146
Whippet1X4AWG+4AWG21.1575.71.1424.6776.367.8214.34148
Schnauzer1X2AWG+2AWG33.6277.21.1439.2578.0212.4517.5226
Heeler1X1/0AWG+1/0AWG53.49199.21.5262.48710.119.8322.35364
Triplex
Hippa2X6AWG+30.58MCM13.374.661.1415.575.044.9313.58154
Bamacle2X4AWG+48.69MCM21.1575.71.1424.6776.367.8216.03230
Shrimp2X2AWG+77.47MCM33.6277.21.1439.2578.0112.4519.36349
Gammarus2X1/0AWG+123.3MCM53.5179.21.5262.48710.1119.8324.84562
Cyclops2X2/0AWG+155.4MCM67.441910.31.5278.74711.3423.9627.3693
Flustra2X3/0AWG+195.7MCM85.031911.61.5299.16712.7530.1830.18858
Lepas2X4/0AWG+246.9MCM107.2219131.52125.11714.3138.0533.311064
Crab2X4AWG+30.58MCM21.1575.71.1415.575.044.9315.08205
Solaster2X2AWG+48.69MCM33.6277.21.1424.6776.367.8218.18309
Sandcrab2X1/0AWG+77.47MCM53.5179.21.5239.2578.0112.4523.33498
Sipho2X2/0AWG+97.65MCM67.441910.31.5249.487915.6925.62613
Fulgar2X3/0AWG+123.3MCM85.031911.61.5262.48710.1119.8328.28757
Arca2X4/0AWG+155.4AWG107.2219131.5278.74711.3423.9631.18936
QUADRUPLEX
French Coach3X6AWG+30.58MCM13.374.661.1415.575.044.9342615.61211
Arabian3X4AWG+48.69MCM21.1575.71.1424.6776.367.8236918.29312
Belgian3X2AWG+77.47MCM33.6277.21.1439.2578.0112.446822469
Shetland3X1/0AWG+123.3MCM53.51199.21.5262.48710.1119.825928.26757
Thoroughbred3X2/0AWG+155.4MCM67.441910.31.5278.74711.3423.960131932
Trotter3X3/0AWG+195.7MCM85.031911.61.5299.16712.7530.183534.21151
Walking3X4/0AWG+246.9MCM107.219131.52125.1714.3138.051637.681424

 

ACSR Conductor Supported Service Drop Cable- ICEA S-76-474
Code NameSizeAl Phase CoreACSR Messenger
Cross-section AreaStr. No.Dia.Insulation Nominal ThicknessCross-section AreaAl WireSt WireStranded Dia.
Str.Dia.Str. No.Dia.
No.
AWG/MCMmm2No.smmmmmm2No.smmNo.smmmm
DUPLEX           
Shepherd1X6+613.374.681.1413.361.6811.685.04
Terrier1X4+421.175.71.1421.1562.1212.126.36
Chow1X2+233.677.21.1433.6262.6712.678.01
Bull1X1/0+1/053.5199.21.5253.5163.3713.3710.11
TRIPLEX           
Voluta2X6+613.374.661.1413.361.6811.685.04
Periwinkle2X4+421.175.71.1421.1562.1212.126.36
Conch2X2+633.677.21.1413.362.6712.678.01
Neritina2X1/0+1/053.579.21.5253.5163.3713.3410.02
Triton2X2/0+2/067.41910.31.5267.4463.7813.7811.34
Mursia2X3/0+3/0851911.61.5285.0364.2514.2512.75
Zuzara2X4/0+4/0107.219131.52107.2264.7714.7714.31
Limpet2X336.4+336.4170.41916.562.03170.46183.4713.4717.35
Strombus2X4+621.175.71.1413.361.6811.685.04
Cockle2X2+433.677.21.1421.1562.1212.126.36
Janthina2X1/0+253.579.21.5233.6262.6712.678.01
Ranella2X1/0+253.5199.21.5233.6262.6712.678.01
Clio2X2/0+167.41910.31.5242.4163139
Aega2X3/0+1/0851911.61.5253.5163.3713.3710.11
Cerapus2X4/0+2/0107.219131.5267.4463.7813.7811.34
Cowry2X336.4+4/0170.41916.592.03107.2264.7714.7714.31
QUADRUPLEX           
Chola3X6+613.374.661.1413.361.6811.685.04
Hackney3X4+421.175.71.1421.1562.1212.126.36
Pallomino3X2+233.677.21.1433.6262.6712.678.01
Costena3X1/0+1/053.5199.21.5253.5163.3713.3710.11
Grullo3X2/0+2/067.41910.31.5267.4463.7813.7811.34
Suffolk3X3/0+3/0851911.61.5285.0364.2514.2512.75
Appaloosa3X4/0+4/0107.219131.52107.2264.7714.7714.31
Gelding3X336.4+4/0170.41916.562.03107.2264.7714.7714.31

 

PDF Download

PDF Download

WHY CHOOSE US

INOUIRY NOW

CONTACT US

24-hour online service

Own factory processing

PRODUCT CATEGORY

HOT-SALE PRODUCT

0.6/1kV ABC cable built to GB/T 12527 standard….

PE/XLPE insulated bundled cables – low maintenance …

Factory-supplied LV/MV ABC cable – IEC, BS, NFC …

CONTACT USIMMEDIATELY