Type CC Type CCT Covered Conductors (ASNZS 3675)

Home > Products > Aerial Bunch Cable > Type CC Type CCT Covered Conductors (ASNZS 3675)

Type CC Type CCT Covered Conductors (ASNZS 3675)

Type CC & CCT covered conductors built to AS/NZS 3675 standards.

Reliable overhead solution with tough weather-resistant covering.

Designed for safe, compact, and low-maintenance distribution lines.

Hard-drawn aluminum conductors with UV-stabilized insulation.

Ideal for bushfire-prone and high-clearance areas in ANZ networks.

Application

Type CC and Type CCT Covered Conductors are overhead low-voltage cables manufactured in compliance with AS/NZS 3675, specifically developed for Australian and New Zealand distribution networks in bushfire-prone and high-risk environments.

These conductors consist of a hard-drawn aluminum or aluminum alloy conductor covered with dual-layer or triple-layer UV-resistant thermoplastic insulation.

  • Type CC features a two-layer covering, offering basic insulation and resistance to accidental contact, trees, and environmental exposure.

  • Type CCT includes a third carbon-blackened UV protection layer, enhancing durability in extreme solar radiation and long-term outdoor installations.

Both types maintain electrical continuity with ground, enabling effective system protection and fault detection—unlike fully insulated systems. They provide a safer alternative to bare conductors while preserving the simplicity of open-wire installation.

Type CC and CCT conductors are ideal for use in rural networks, agricultural areas, roadside lines, and regions requiring enhanced fire mitigation, especially under Australia’s bushfire compliance guidelines. They are compatible with standard pole hardware and deliver low maintenance, long service life, and improved public safety.

Specifications

CategoryTechnical DescriptionTypical Applications
StandardAS/NZS 3675 – Specifies covered overhead conductors for use in LV/MV distribution networksWidely used in Australia and New Zealand, especially in bushfire-prone and vegetated rural areas
Conductor TypesType CC: Circular Stranded Aluminum 1350-H19Type CCT: Thermal-Resistant Aluminum Alloy (TRAA) conductor (better sag & thermal profile)Type CCT preferred for high-temperature operation and better mechanical performance
Covering Material– Thick-wall UV-resistant cross-linked polyethylene (XLPE) or high-density polyethylene (HDPE)Provides mechanical protection and partial insulation; not rated for full dielectric withstand
Voltage Class– Generally used up to 22 kV (MV)- Typical: 6.35/11 kV, 12.7/22 kVSuitable for overhead rural feeders, spur lines, fire-risk zones
Insulation StatusCovered, not insulated – conductor is touch-protected but air clearance requirements remainInstalled on insulators, unlike ABC cables
Color / MarkingUsually black outer layer with indented markings for phase ID and traceabilityEnsures easy identification during installation and maintenance
AttributeType CCType CCT
Conductor Material1350-H19 aluminumThermal-resistant aluminum alloy (e.g., 1120, 6201)
Operating TemperatureTypically 90°CUp to 110°C continuous, 130°C overload
Sag ResistanceModerate (standard aluminum sag)Improved – better tension handling in long spans
Current CarryingStandard ampacitySlightly higher due to improved thermal rating
Mechanical StrengthGoodBetter – suited for longer pole spacing and wind zones
Application PreferenceGeneral overhead installationsBushfire zones, hot climates, difficult terrain, retrofit upgrades

Parameter

Type CC & Type CCT 11kv 22kv 33kv Covered Conductor
Conductor size No./mmConductor d.c. resistance at 20°CConductor a.c. resistance at 80°CReactance at 50 Hz (460 mm spacing)Continuous current carrying capacityFault current rating kA for 1 sec.*Everday working tensionf kNMaximum working tension (50% MBL) kNMinimum breaking load kNMinimum bending radius mm
Based on 30°C ambientBased on 40°C ambient
Ω/kmΩ/kmΩ/kmStill air1.0 m/s wind2.0 m/s wind   
Alloy 6201
7/2.750.7990.9880.3311252102351101852103.51.515.811.6200
7/3.750.430.5320.3121803003451602703106.42.8210.921.7245
7/4.750.2680.3310.29724541046522036541510.34.5217.434.8290
19/3.500.1830.2270.28131551559528046053015.26.6725.751.3340
Alloy 1120
7/2.750.7130.8810.3311302202501151952253.71.494.969.91200
7/3.750.3830.4740.3121903203651702853256.82.648.817.6245
7/4.750.2390.2960.297260430485230385435114.0713.627.1290
19/3.500.1630.2020.28133054562529548556016.26.2620.941.7340
TECHNICAL PERFORMANCE CHARACTERISTICS FOR COVERED CONDUCTORS (CCT)
Conductor size No./mmConductor d.c. resistance at 20°CConductor a.c. resistance at 80°CReactance at 50 Hz (460 mm spacing)Continuous current carrying capacityFault current rating kA for 1 sec.*Everday working tensionf kNMaximum working tension (50% MBL) kNMinimum breaking load kNMinimum bending radius mm
Based on 30°C ambientBased on 40°C ambient
Ω/kmΩ/kmΩ/kmStill air1.0 m/s wind2.0 m/s wind   
11 kv covered conductor Alloy 6201
7/3.750.430.5320.3121852953301652652956.42.8210.921.7285
7/4.750.2680.3310.29724539044022035039510.34.5217.434.8330
19/3.500.1830.2270.28131550056028044550015.26.6725.751.3380
22 kV covered conductor Alloy 6201
7/3.750.430.5320.3121852853151652552806.42.8210.921.7350
7/4.750.2680.3310.29724537542022033537510.34.5217.434.8395
19/3.500.1830.2270.28131547553028042547515.26.6725.751.3445
33kv covered conductor Alloy 6201
7/3.750.430.5320.3121852702951652402656.42.8210.921.7425
7/4.750.2680.3310.29724536040022032035510.34.5217.434.8470
19/3.500.1830.2270.28131545550528040545015.26.6725.751.3520
XLPE covered aerial cables Alloy 1120 conductors
Conductor size No./mmConductor d.c. resistance at 20°CConductor a.c. resistance at 80°CReactance at 50 Hz (460 mm spacing)Continuous current carrying capacityFault current rating kA for 1 sec.*Everday working tensionf kNMaximum working tension (50% MBL) kNMinimum breaking load kNMinimum bending radius mm
Based on 30°C ambientBased on 40°C ambient
Ω/kmΩ/kmΩ/kmStill air1.0 m/s wind2.0 m/s wind   
11kv covered conductor Alloy 1120
7/2.750.7130.8810.3311302152401151902153.71.494.969.9230
7/3.750.3830.4740.3121903153451702803106.82.648.817.6285
7/4.750.2390.2960.29726()415470230370420114.0713.627.1330
19/3.500.1630.2020.28133052559529547053016.26.2620.941.7380
22 kV covered conductor Alloy 1120
7/2.750.7130.8810.3311352052251201852003.71.494.969.9300
7/3.750.3830.4740.3121902953301702652956.82.648.817.6350
7/4.750.2390.2960.297260400440230355395114.0713.627.1395
19/3.500.1630.2020.28133050556029545050016.26.2620.941.7445
33kv covered conductor Alloy 1120
7/2.750.7130.8810.3311351952151201751903.71.494.969.9385
7/3.750.3830.4740.3121952853151752552806.82.648.817.6425
7/4.750.2390.2960.297260380420230340375114.0713.627.1470
19/3.500.1630.2020.28133048053029543047516.26.2620.941.7520
* Initial temperature 80°C, final temperature 210°C, constant K = 83.0 for alloy 6201 and 88.4 for alloy 1120. f 13% MBL fbr alloy 6201 and 15% MBL for alloy 1120.

 

PDF Download

PDF Download