PE and XLPE Insulated Overhead Bundled Cables
Home > Products > Aerial Bunch Cable > PE and XLPE Insulated Overhead Bundled Cables
PE and XLPE Insulated Overhead Bundled Cables
PE and XLPE aerial cables designed for harsh outdoor environments.
Insulated bundled conductors with excellent mechanical strength.
Ideal for overhead distribution where space and safety matter.
UV-resistant and insulated for long-lasting power reliability.
PE/XLPE insulated bundled cables – low maintenance, high performance.
Application
PE and XLPE Insulated Overhead Bundled Cables are advanced low- and medium-voltage aerial distribution cables designed for improved safety, reliability, and resistance to harsh environments. These cables consist of aluminum or aluminum alloy conductors, tightly bundled and insulated with either polyethylene (PE) or cross-linked polyethylene (XLPE).
PE insulation offers good mechanical strength, flexibility, and water resistance, making it suitable for moderate climates and standard utility applications. XLPE insulation, on the other hand, provides superior thermal performance, dielectric strength, and aging resistance, enabling continuous operation at 90°C and short-circuit conditions up to 250°C, ideal for hotter climates or heavy-load conditions.
These overhead bundled cables are widely used in urban grids, rural electrification, and forested or coastal areas, where space constraints, vegetation contact, and safety are major concerns. Their compact and insulated design allows for reduced pole spacing, easier installation, and lower maintenance compared to bare conductor systems.
Manufactured to comply with IEC 60502, BS 7870, AS/NZS 3560.1, and other international standards, PE and XLPE insulated bundled cables are a cost-effective, durable, and safe solution for modern overhead power distribution networks.
Specifications
| Standard | Construction & Material Details | Typical Applications & Regional Context |
|---|---|---|
| AS/NZS 3560.1 | – LV bundled conductor cable (0.6/1 kV)- Conductors: 1350-H19 aluminum, circular stranded- Insulation: UV-stabilized XLPE– Twisted cores with insulated neutral or bare messenger | – Used extensively in Australian rural/urban networks– Optimized for bushfire zones & vegetation-rich areas |
| AS/NZS 3599.1 / 3599.2 | – MV aerial cable (6.35/11 kV, 12.7/22 kV, 19/33 kV)- XLPE-insulated, screened, water-tree retardant- Semi-conductive conductor shield, copper wire/tape screen, optional HDPE outer sheath | – Standard for MV overhead reticulation across New Zealand & Australia– Often used where underground cabling is impractical |
| IEC 60502 (Part 1 & 2) | – International framework for LV and MV power cables– Supports PE or XLPE insulation, optional HDPE sheathing- Allows design flexibility in core configuration and screening | – Global utility projects, often adapted into national ABC specifications in Africa, Asia, Latin America |
| BS 7870-5 | – LV aerial cable (0.6/1 kV)– Conductors: Aluminum, compacted or circular stranded- Insulation: XLPE to BS EN 50397– Self-supporting or catenary neutral types | – Used in UK-style suburban overhead networks, often for municipal power upgrades or pole-to-building drops |
| Parameter | PE (Polyethylene) | XLPE (Cross-linked Polyethylene) |
|---|---|---|
| Type | Thermoplastic – softens under heat | Thermoset – maintains form under high temperature |
| Thermal Performance | Operating temp: 70–75°CMax short-circuit: ~130°C | Operating temp: 90°CShort-circuit: 250°C |
| UV Resistance | Moderate – enhanced with additives like carbon black | Excellent – inherently UV-resistant, preferred for long-term outdoor use |
| Electrical Strength | Moderate dielectric strength (~22–30 kV/mm) | Higher dielectric strength (~30–45 kV/mm), excellent resistance to water treeing |
| Mechanical Behavior | Flexible, good elongation, but less abrasion-resistant | Tougher, stiffer, more resistant to deformation and mechanical stress |
| Cost Efficiency | Lower material cost | Slightly higher cost, but longer lifespan and greater stability |
| Flame Resistance | Low – unless modified | High – compliant with fire-rated cable standards, ideal for bushfire-prone zones |
Parameter
AS/NZS 3560.1 0.6/1kV (Low Voltage) 🇦🇺 Australia, 🇳🇿 New Zealand, Fiji, Papua New Guinea, and other Pacific Island countries. Widely used in Australia and New Zealand.
| AL/XLPE INSULATED AERIAL BUNDLED CABLES AS/NZS 3560.1 0.6/1 (1.2) kV | |||||||||
| Phase conductor | |||||||||
| Nominal cross-sectional area | mm2 | 16 | 25 | 35 | 50 | 95 | 25 | 35 | 50 |
| Number of cores | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | |
| Minimum number of wires | 6 | 6 | 6 | 6 | 15 | 6 | 6 | 6 | |
| Nominal insulation thickness | mm | 1.3 | 1.3 | 1.3 | 1.5 | 1.7 | 1.3 | 1.3 | 1.5 |
| Diameter of insulated core | mm | 7.5 | 8.8 | 9.8 | 11.4 | 15.3 | 8.8 | 9.8 | 11.4 |
| Max. dc resistance at 20°C | ohm/km | 1.91 | 1.2 | 0.868 | 0.641 | 0.32 | 1.2 | 0.868 | 0.641 |
| Current rating for typical Australian | A | 78 | 105 | 125 | 150 | 230 | 97 | 120 | 140 |
| installation conditions Conductor temperature = 80°C | |||||||||
| Neutral conductor | |||||||||
| Nominal cross-sectional area | mm2 | 16 | 25 | 35 | 50 | 95 | 25 | 35 | 50 |
| Minimum number of wires | 6 | 6 | 6 | 6 | 15 | 6 | 6 | 6 | |
| Nominal insulation thickness | mm | 1.3 | 1.3 | 1.3 | 1.5 | 1.7 | 1.3 | 1.3 | 1.5 |
| Diameter of insulated core | mm | 7.5 | 8.8 | 9.8 | 11.4 | 15.3 | 8.8 | 9.8 | 11.4 |
| Max. dc resistance at 20°C | ohm/km | 1.91 | 1.2 | 0.868 | 0.641 | 0.32 | 1.2 | 0.868 | 0.641 |
| Completed cable | |||||||||
| Minimum breaking load | kN | 4.4 | 7 | 9.8 | 14 | 26.6 | 10.5 | 14.7 | 21 |
| Approx. overall diameter | mm | 15 | 17.6 | 19.6 | 22.8 | 30.6 | 19 | 21.1 | 24.6 |
| Approx. weight of cable | kg/km | 140 | 210 | 270 | 370 | 680 | 310 | 410 | 550 |
| Packing length | m/drum | 1000 | 1000 | 1000 | 1000 | 500 | 1000 | 1000 | 1000 |
| Phase conductor | |||||||||
| Nominal cross-sectional area | mm2 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 6 | 12 | 15 | 15 | 15 | |
| Nominal insulation thickness | mm | 1.3 | 1.3 | 1.3 | 1.5 | 1.5 | 1.7 | 1.7 | 1.7 |
| Diameter of insulated core | mm | 7.5 | 8.8 | 9.8 | 11.4 | 13.2 | 15.3 | 16.8 | 18.2 |
| Max. dc resistance at 20°C | ohm/km | 1.91 | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 |
| Current rating for typical Australian installation | A | 74 | 97 | 120 | 140 | 175 | 215 | 250 | 280 |
| conditions Conductor temperature = 80°C | |||||||||
| Neutral conductor | |||||||||
| Nominal cross-sectional area | mm2 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 |
| Minimum number of wires | 6 | 6 | 6 | 6 | 12 | 15 | 15 | 15 | |
| Nominal insulation thickness | mm | 1.3 | 1.3 | 1.3 | 1.5 | 1.5 | 1.7 | 1.7 | 1.7 |
| Diameter of insulated core | mm | 7.5 | 8.8 | 9.8 | 11.4 | 13.2 | 15.3 | 16.8 | 18.2 |
| Max. dc resistance at 20°C | ohm/km | 1.91 | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 |
| Completed cable | |||||||||
| Minimum breaking load | kN | 8.8 | 14 | 19.6 | 28 | 39.2 | 53.2 | 67.2 | 84 |
| Approx. overall diameter | mm | 18.1 | 21.2 | 23.7 | 27.5 | 31.9 | 36.9 | 40.6 | 43.9 |
| Approx. weight of cable | kg/km | 290 | 410 | 550 | 740 | 1000 | 1370 | 1690 | 2020 |
| Packing length | m/drum | 1000 | 1000 | 1000 | 1000 | 1000 | 500 | 500 | 500 |
AS/NZS 3599.1 6.35/11kV, 12.7/22kV (Medium Voltage) Same as above. Common standard for medium-voltage bundled cables, used in overhead power distribution systems.
| AL/XLPE/SCW/HDPE AERIAL BUNDLED CABLES AS/NZS 3599.1 (Light Duty Screen) 6.35/11 (12) kV | |||||||||
| Phase conductor | |||||||||
| Nominal cross-sectional area | mm2 | 35 | 35 | 50 | 70 | 95 | 120 | 150 | l85 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 12 | 15 | l8 | l8 | 30 | |
| Nominal diameter of conductor | mm | 7 | 7 | 8.l | 9.7 | l4.5 | 12.9 | l4.3 | 16.1 |
| Minimum thickness of conductor screen | mm | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
| Nominal thickness of XLPE insulation | mm | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 |
| Minimum thickness of insulation screen | mm | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 |
| No. and diameter of metallic screening approx. of copper wire | no./mm | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 |
| Nominal thickness of outer sheath | mm | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.9 |
| Nominal diameter over sheathing | mm | 24.2 | 24.2 | 25.1 | 26.7 | 28.4 | 29.9 | 31.3 | 33.2 |
| Max. dc resistance at 20°C | ohm/km | 0.868 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 |
| Current rating at Ambient temperature = 30°C | A | 185 | 185 | 210 | 260 | 315 | 365 | 415 | 475 |
| Ambient temperature = 40°C Solar radiation = IOOOw/m2 Wind speed = lm/s | A | 155 | 155 | l85 | 230 | 280 | 325 | 370 | 425 |
| Earth fault current carrying capacity of metallic screen at -1 second ( 1 core ) | kA | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| Messenger Galvanized steel wire | |||||||||
| Stranding | No./mm | 7/2.0 | 19/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 |
| Direction of the outermost layer | Righthand (Z) | ||||||||
| Overall diameter | mm | 6 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| Completed cable | |||||||||
| Approx. overall diameter | mm | 54.4 | 58.4 | 60.1 | 63.4 | 66.8 | 69.8 | 72.6 | 76.4 |
| Approx. weight of cable | kg/km | l890 | 2190 | 2320 | 2610 | 2960 | 3260 | 3590 | 4060 |
| Packing length | m/drum | 500 | 500 | 500 | 500 | 500 | 500 | 250 | 250 |
| AL/XLPE/SCW/HDPE AERIAL BUNDLED CABLES AS/NZS 3599.1 (Heavy Duty Screen) 6.35/11 (12) kV | |||||||||
| Phase conductor | |||||||||
| Nominal cross.sectional area | mm2 | 35 | 35 | 50 | 70 | 95 | 120 | 150 | l85 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 12 | 15 | l8 | l8 | 30 | |
| Nominal diameter of conductor | mm | 7 | 7 | 8.l | 9.7 | 11.5 | 12.9 | l4.3 | 16.1 |
| Minimum thickness of conductor screen | mm | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
| Nominal thickness of XLPE insulation | mm | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 |
| Minimum thickness of insulation screen | mm | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 |
| No. and diameter of metallic screening approx. of copper wire | no./mm | 40/0.85 | 40/0.85 | 23/l.35 | 32/l.35 | 38/l.35 | 38/l.35 | 38/l.35 | 38/l.35 |
| Nominal thickness of outer sheath | mm | l.8 | l.8 | l.8 | l.8 | l.8 | l.8 | l.8 | 1.9 |
| Nominal diameter over sheathing | mm | 24.2 | 24.2 | 26.1 | 27.7 | 29.4 | 30.9 | 32.3 | 34.2 |
| Max. dc resistance at 20°C | ohm/km | 0.868 | 0.868 | 0.64l | 0.443 | 0.32 | 0.253 | 0.206 | 0.l64 |
| Current rating at Ambient temperature = 30°C | A | l85 | l85 | 210 | 260 | 315 | 365 | 4l5 | 475 |
| Ambient temperature = 40°C Solar radiation = I000w/m2 Wind speed = lm/s | A | 155 | 155 | l85 | 230 | 280 | 325 | 370 | 425 |
| Earth fault current carrying capacity of metallic screen at -1 second ( 1 Core ) | kA | 3.3 * | 3.3 * | 4.8* | 6.8* | 8 | 8 | 8 | 8 |
| Messenger Galvanized steel wire | |||||||||
| Stranding | No./mm | 7/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 |
| Direction of the outermost layer | Right-hand (Z) | ||||||||
| Overall diameter | mm | 6 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| Completed cable | |||||||||
| Approx. overall diameter | mm | 54.4 | 58.4 | 62.1 | 65.4 | 68.8 | 7l.8 | 74.6 | 78.4 |
| Approx. weight of cable | kg/km | 2150 | 2440 | 2880 | 3540 | 4l30 | 4440 | 4770 | 5240 |
| Packing length | m/drum | 500 | 500 | 500 | 500 | 500 | 500 | 250 | 250 |
| AL/XLPE/SCW/HDPE AERIAL BUNDLED CABLES AS/NZS 3599.1 (Light Duty Screen) 12.7/22 (24) kV | |||||||||
| Phase conductor | |||||||||
| Nominal cross-sectional area | mm2 | 35 | 35 | 50 | 70 | 95 | 120 | 150 | l85 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 12 | 15 | l8 | l8 | 30 | |
| Nominal diameter of conductor | mm | 7 | 7 | 8.l | 9.7 | 11.5 | 12.9 | l4.3 | 16.1 |
| Minimum thickness of conductor screen | mm | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
| Nominal thickness of XLPE insulation | mm | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 |
| Minimum thickness of insulation screen | mm | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 |
| No. and diameter of metallic screening approx. of copper wire | no./mm | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 |
| Nominal thickness of outer sheath | mm | 1.8 | 1.8 | 1.8 | 1.8 | 1.9 | 1.9 | 2 | 2 |
| Nominal diameter over sheathing | mm | 28.4 | 28.4 | 29.3 | 30.9 | 32.8 | 34.3 | 35.9 | 37.6 |
| Max. dc resistance at 20°C | ohm/km | 0.868 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 |
| Current rating at Ambient temperature = 30°C | A | 170 | 170 | 205 | 260 | 315 | 360 | 4l0 | 470 |
| Ambient temperature = 40°C Solar radiation = IOOOw/m2 Wind speed = lm/s | A | 150 | 150 | l85 | 230 | 280 | 320 | 365 | 4l5 |
| Earth fault current carrying capacity of metallic screen at -1 second ( 1 Core ) | kA | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| Messenger Galvanized steel wire | |||||||||
| Stranding | No./mm | 7/2.0 | 19/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 |
| Direction of the outermost layer | Righthand (Z) | ||||||||
| Overall diameter | mm | 6 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| Completed cable | |||||||||
| Approx. overall diameter | mm | 62.8 | 66.8 | 68.5 | 7l.8 | 75.6 | 78.6 | 8l.8 | 85.2 |
| Approx. weight of cable | kg/km | 2340 | 2640 | 2780 | 3100 | 3510 | 3850 | 4240 | 47l0 |
| Packing length | m/drum | 500 | 500 | 500 | 250 | 250 | 250 | 250 | 250 |
| AL/XLPE/SCW/HDPE AERIAL BUNDLED CABLES AS/NZS 3599.1 (Heavy Duty Screen) 12.7/22 (24) kV | |||||||||
| Phase conductor | |||||||||
| Nominal cross.sectional area | mm2 | 35 | 35 | 50 | 70 | 95 | 120 | 150 | l85 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 12 | 15 | l8 | l8 | 30 | |
| Nominal diameter of conductor | mm | 7 | 7 | 8.l | 9.7 | 11.5 | 12.9 | l4.3 | 16.1 |
| Minimum thickness of conductor screen | mm | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
| Nominal thickness of XLPE insulation | mm | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 |
| Minimum thickness of insulation screen | mm | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 |
| No. and diameter of metallic screening approx. of copper wire | no./mm | 40/0.85 | 40/0.85 | 23/l.35 | 32/l.35 | 38/l.35 | 38/l.35 | 38/l.35 | 38/l.35 |
| Nominal thickness of outer sheath | mm | l.8 | l.8 | l.8 | l.8 | 1.9 | 1.9 | 2 | 2 |
| Nominal diameter over sheathing | mm | 28.4 | 28.4 | 30.3 | 31.9 | 33.8 | 35.3 | 36.9 | 38.6 |
| Max. dc resistance at 20°C | ohm/km | 0.868 | 0.868 | 0.64l | 0.443 | 0.32 | 0.253 | 0.206 | 0.l64 |
| Current rating at Ambient temperature = 30°C | A | 170 | 170 | 205 | 260 | 315 | 360 | 4l0 | 470 |
| Ambient temperature = 40°C Solar radiation = I000w/m2 Wind speed = lm/s | A | 150 | 150 | 185 | 230 | 280 | 320 | 365 | 4l5 |
| Earth fault current carrying capacity of metallic screen at -1 second ( 1 Core ) | kA | 3.3 * | 3.3 * | 4.8* | 6.8* | 8 | 8 | 8 | 8 |
| Messenger Galvanized steel wire | |||||||||
| Stranding | No./mm | 7/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 |
| Direction of the outermost layer | Right-hand (Z) | ||||||||
| Overall diameter | mm | 6 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| Completed cable | |||||||||
| Approx. overall diameter | mm | 62.8 | 66.8 | 70.5 | 73.8 | 77.6 | 80.6 | 83.8 | 87.2 |
| Approx. weight of cable | kg/km | 2600 | 2900 | 3350 | 4030 | 4680 | 5020 | 54l0 | 5880 |
| Packing length | m/drum | 500 | 500 | 500 | 250 | 250 | 250 | 250 | 250 |
AS/NZS 3599.2 Reinforced Medium Voltage Same as above. Used in mountainous, forested, and high-tension environments.
| AL/XLPE/SCW/HDPE AERIAL BUNDLED CABLES AS/NZS 3599.1 (Light Duty Screen) 6.35/11 (12) kV | |||||||||
| Phase conductor | |||||||||
| Nominal cross-sectional area | mm2 | 35 | 35 | 50 | 70 | 95 | 120 | 150 | l85 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 12 | 15 | l8 | l8 | 30 | |
| Nominal diameter of conductor | mm | 7 | 7 | 8.l | 9.7 | l4.5 | 12.9 | l4.3 | 16.1 |
| Minimum thickness of conductor screen | mm | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
| Nominal thickness of XLPE insulation | mm | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 |
| Minimum thickness of insulation screen | mm | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 |
| No. and diameter of metallic screening approx. of copper wire | no./mm | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 |
| Nominal thickness of outer sheath | mm | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.9 |
| Nominal diameter over sheathing | mm | 24.2 | 24.2 | 25.1 | 26.7 | 28.4 | 29.9 | 31.3 | 33.2 |
| Max. dc resistance at 20°C | ohm/km | 0.868 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 |
| Current rating at Ambient temperature = 30°C | A | 185 | 185 | 210 | 260 | 315 | 365 | 415 | 475 |
| Ambient temperature = 40°C Solar radiation = IOOOw/m2 Wind speed = lm/s | A | 155 | 155 | l85 | 230 | 280 | 325 | 370 | 425 |
| Earth fault current carrying capacity of metallic screen at -1 second ( 1 core ) | kA | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| Messenger Galvanized steel wire | |||||||||
| Stranding | No./mm | 7/2.0 | 19/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 |
| Direction of the outermost layer | Righthand (Z) | ||||||||
| Overall diameter | mm | 6 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| Completed cable | |||||||||
| Approx. overall diameter | mm | 54.4 | 58.4 | 60.1 | 63.4 | 66.8 | 69.8 | 72.6 | 76.4 |
| Approx. weight of cable | kg/km | l890 | 2190 | 2320 | 2610 | 2960 | 3260 | 3590 | 4060 |
| Packing length | m/drum | 500 | 500 | 500 | 500 | 500 | 500 | 250 | 250 |
| AL/XLPE/SCW/HDPE AERIAL BUNDLED CABLES AS/NZS 3599.1 (Heavy Duty Screen) 6.35/11 (12) kV | |||||||||
| Phase conductor | |||||||||
| Nominal cross.sectional area | mm2 | 35 | 35 | 50 | 70 | 95 | 120 | 150 | l85 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 12 | 15 | l8 | l8 | 30 | |
| Nominal diameter of conductor | mm | 7 | 7 | 8.l | 9.7 | 11.5 | 12.9 | l4.3 | 16.1 |
| Minimum thickness of conductor screen | mm | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
| Nominal thickness of XLPE insulation | mm | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 |
| Minimum thickness of insulation screen | mm | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 |
| No. and diameter of metallic screening approx. of copper wire | no./mm | 40/0.85 | 40/0.85 | 23/l.35 | 32/l.35 | 38/l.35 | 38/l.35 | 38/l.35 | 38/l.35 |
| Nominal thickness of outer sheath | mm | l.8 | l.8 | l.8 | l.8 | l.8 | l.8 | l.8 | 1.9 |
| Nominal diameter over sheathing | mm | 24.2 | 24.2 | 26.1 | 27.7 | 29.4 | 30.9 | 32.3 | 34.2 |
| Max. dc resistance at 20°C | ohm/km | 0.868 | 0.868 | 0.64l | 0.443 | 0.32 | 0.253 | 0.206 | 0.l64 |
| Current rating at Ambient temperature = 30°C | A | l85 | l85 | 210 | 260 | 315 | 365 | 4l5 | 475 |
| Ambient temperature = 40°C Solar radiation = I000w/m2 Wind speed = lm/s | A | 155 | 155 | l85 | 230 | 280 | 325 | 370 | 425 |
| Earth fault current carrying capacity of metallic screen at -1 second ( 1 Core ) | kA | 3.3 * | 3.3 * | 4.8* | 6.8* | 8 | 8 | 8 | 8 |
| Messenger Galvanized steel wire | |||||||||
| Stranding | No./mm | 7/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 |
| Direction of the outermost layer | Right-hand (Z) | ||||||||
| Overall diameter | mm | 6 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| Completed cable | |||||||||
| Approx. overall diameter | mm | 54.4 | 58.4 | 62.1 | 65.4 | 68.8 | 7l.8 | 74.6 | 78.4 |
| Approx. weight of cable | kg/km | 2150 | 2440 | 2880 | 3540 | 4l30 | 4440 | 4770 | 5240 |
| Packing length | m/drum | 500 | 500 | 500 | 500 | 500 | 500 | 250 | 250 |
| AL/XLPE/SCW/HDPE AERIAL BUNDLED CABLES AS/NZS 3599.1 (Light Duty Screen) 12.7/22 (24) kV | |||||||||
| Phase conductor | |||||||||
| Nominal cross-sectional area | mm2 | 35 | 35 | 50 | 70 | 95 | 120 | 150 | l85 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 12 | 15 | l8 | l8 | 30 | |
| Nominal diameter of conductor | mm | 7 | 7 | 8.l | 9.7 | 11.5 | 12.9 | l4.3 | 16.1 |
| Minimum thickness of conductor screen | mm | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
| Nominal thickness of XLPE insulation | mm | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 |
| Minimum thickness of insulation screen | mm | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 |
| No. and diameter of metallic screening approx. of copper wire | no./mm | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 |
| Nominal thickness of outer sheath | mm | 1.8 | 1.8 | 1.8 | 1.8 | 1.9 | 1.9 | 2 | 2 |
| Nominal diameter over sheathing | mm | 28.4 | 28.4 | 29.3 | 30.9 | 32.8 | 34.3 | 35.9 | 37.6 |
| Max. dc resistance at 20°C | ohm/km | 0.868 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 |
| Current rating at Ambient temperature = 30°C | A | 170 | 170 | 205 | 260 | 315 | 360 | 4l0 | 470 |
| Ambient temperature = 40°C Solar radiation = IOOOw/m2 Wind speed = lm/s | A | 150 | 150 | l85 | 230 | 280 | 320 | 365 | 4l5 |
| Earth fault current carrying capacity of metallic screen at -1 second ( 1 Core ) | kA | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| Messenger Galvanized steel wire | |||||||||
| Stranding | No./mm | 7/2.0 | 19/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 | l9/2.0 |
| Direction of the outermost layer | Righthand (Z) | ||||||||
| Overall diameter | mm | 6 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| Completed cable | |||||||||
| Approx. overall diameter | mm | 62.8 | 66.8 | 68.5 | 7l.8 | 75.6 | 78.6 | 8l.8 | 85.2 |
| Approx. weight of cable | kg/km | 2340 | 2640 | 2780 | 3100 | 3510 | 3850 | 4240 | 47l0 |
| Packing length | m/drum | 500 | 500 | 500 | 250 | 250 | 250 | 250 | 250 |
| AL/XLPE/SCW/HDPE AERIAL BUNDLED CABLES AS/NZS 3599.1 (Heavy Duty Screen) 12.7/22 (24) kV | |||||||||
| Phase conductor | |||||||||
| Nominal cross.sectional area | mm2 | 35 | 35 | 50 | 70 | 95 | 120 | 150 | l85 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 12 | 15 | l8 | l8 | 30 | |
| Nominal diameter of conductor | mm | 7 | 7 | 8.l | 9.7 | 11.5 | 12.9 | l4.3 | 16.1 |
| Minimum thickness of conductor screen | mm | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
| Nominal thickness of XLPE insulation | mm | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 |
| Minimum thickness of insulation screen | mm | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 |
| No. and diameter of metallic screening approx. of copper wire | no./mm | 40/0.85 | 40/0.85 | 23/l.35 | 32/l.35 | 38/l.35 | 38/l.35 | 38/l.35 | 38/l.35 |
| Nominal thickness of outer sheath | mm | l.8 | l.8 | l.8 | l.8 | 1.9 | 1.9 | 2 | 2 |
| Nominal diameter over sheathing | mm | 28.4 | 28.4 | 30.3 | 31.9 | 33.8 | 35.3 | 36.9 | 38.6 |
| Max. dc resistance at 20°C | ohm/km | 0.868 | 0.868 | 0.64l | 0.443 | 0.32 | 0.253 | 0.206 | 0.l64 |
| Current rating at Ambient temperature = 30°C | A | 170 | 170 | 205 | 260 | 315 | 360 | 4l0 | 470 |
| Ambient temperature = 40°C Solar radiation = I000w/m2 Wind speed = lm/s | A | 150 | 150 | 185 | 230 | 280 | 320 | 365 | 4l5 |
| Earth fault current carrying capacity of metallic screen at -1 second ( 1 Core ) | kA | 3.3 * | 3.3 * | 4.8* | 6.8* | 8 | 8 | 8 | 8 |
| Messenger Galvanized steel wire | |||||||||
| Stranding | No./mm | 7/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 |
| Direction of the outermost layer | Right-hand (Z) | ||||||||
| Overall diameter | mm | 6 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| Completed cable | |||||||||
| Approx. overall diameter | mm | 62.8 | 66.8 | 70.5 | 73.8 | 77.6 | 80.6 | 83.8 | 87.2 |
| Approx. weight of cable | kg/km | 2600 | 2900 | 3350 | 4030 | 4680 | 5020 | 54l0 | 5880 |
| Packing length | m/drum | 500 | 500 | 500 | 250 | 250 | 250 | 250 | 250 |
IEC 60502/TNB 0.6/1kV ~ 30kV Aluminum/polyethylene insulated overhead bundled cable, 🌍 Widely used internationally: in most countries in Africa, the Middle East, Southeast Asia, South Asia, South America, the Commonwealth of Independent States, and more.
| IEC 60502 & TNB Specifcation(0.6/1 (1.2) kV)Cables without street lighting | |||||||||||
| Phase conductor | |||||||||||
| Nominal cross-sectional area | mm2 | 16 * | 16 * | 25 | 35 | 50 | 70 | 95 | 120 | 150 | l85 |
| Number of cores | 1 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 6 | 6 | 12 | 15 | 15 | 30 | 30 | |
| Nominal insulation thickness | mm | 1 | 1 | 1.2 | 1.2 | l.4 | l.4 | 1.6 | 1.6 | l.8 | 2 |
| Diameter of insulated core | mm | 6.8 | 6.8 | 8.5 | 9.5 | 11.2 | 13 | 15.1 | 16.6 | l8.4 | 20.6 |
| Max. dc resistance at 20°C | ohm/km | 1.91 | 1.91 | 1.2 | 0.868 | 0.64l | 0.443 | 0.32 | 0.253 | 0.206 | 0.l64 |
| Current rating at still wind, ambient temperature =30°C, conductor temperature = 75°C | A | 61 | 61 | 84 | l04 | 129 | 167 | 209 | 246 | 283 | 332 |
| Maximum voltage drop | mV/A/m | 4.67 | 4.05 | 2.54 | l.84 | 1.36 | 0.95 | 0.69 | 0.55 | 0.46 | 0.37 |
| Messenger conductor | |||||||||||
| Nominal cross-sectional area | mm2 | 25 | 25 | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
| Minimum number of wires | 6 | 6 | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 | |
| Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | l.4 | l.4 | l.4 | 1.6 | 1.6 |
| Diameter of insulated core | mm | 8.5 | 8.5 | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
| Max. dc resistance at 20°C | ohm/km | 1.312 | 1.312 | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
| Calculated breaking load | kN | 6.4 | 6.4 | 6.4 | 6.4 | 8.9 | 12.1 | l8.0 | l8.0 | 24.2 | 30.8 |
| Completed cable | |||||||||||
| Approx. overall diameter | mm | 15.3 | 19 | 23.2 | 25.6 | 30 | 34.9 | 40.6 | 44.l | 49.2 | 54.9 |
| Approx. weight of cable | kg/km | 160 | 290 | 400 | 500 | 680 | 920 | 1270 | 1510 | l,870 | 2340 |
| Packing length | m/drum | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 500 | 500 | 500 | 500 |
| IEC 60502 & TNB Specifcation(0.6/1 (1.2) kV)Cables with street lighting | |||||||||
| Phase conductor | |||||||||
| Nominal cross-sectional area | mm2 | 25 | 35 | 50 | 70 | 95 * | 120 | 150 | 185* |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 12 | 15 | 15 | 30 | 30 | |
| Nominal insulation thickness | mm | 1.2 | 1.2 | l.4 | l.4 | 1.6 | 1.6 | 1.8 | 2 |
| Diameter of insulated core | mm | 8.5 | 9.5 | 11.2 | 13 | 15.1 | 16.6 | 18.4 | 20.6 |
| Max. dc resistance at 20°C | ohm/km | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 |
| Current rating at still wind, ambient temperature = 30°C, conductor temperature = 75°C | A | 84 | 104 | 129 | 167 | 209 | 246 | 283 | 332 |
| Maximum voltage drop | mV/A/m | 2.54 | 1.84 | 1.36 | 0.95 | 0.69 | 0.55 | 0.46 | 0.37 |
| Messenger conductor | |||||||||
| Nominal cross-sectional area | mm2 | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
| Minimum number of wires | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 | |
| Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | l.4 | l.4 | l.4 | 1.6 | 1.6 |
| Diameter of insulated core | mm | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
| Max. dc resistance at 20°C | ohm/km | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
| Calculated breaking load | kN | 6.4 | 6.4 | 8.9 | 12.1 | l8.0 | l8.0 | 24.2 | 30.8 |
| Street lighting conductor | |||||||||
| Nominal cross-sectional area | mm2 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 |
| Minimum number of wires | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | |
| Nominal insulation thickness | mm | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| Diameter of insulated core | mm | 6.8 | 6.8 | 6.8 | 6.8 | 6.8 | 6.8 | 6.8 | 6.8 |
| Max. dc resistance at 20°C | ohm/km | 1.91 | 1.91 | 1.91 | 1.91 | 1.91 | 1.91 | 1.91 | 1.91 |
| Completed cable | |||||||||
| Approx. overall diameter | mm | 23.2 | 25.6 | 30 | 34.9 | 40.6 | 44.l | 49.2 | 54.9 |
| Approx. weight of cable | kg/km | 470 | 560 | 740 | 980 | 1330 | l,580 | l,940 | 2,4l0 |
| Packing length | m/drum | 1000 | 1000 | 1000 | 1000 | 500 | 500 | 500 | 500 |
| AERIAL BUNDLED CABLES AL/XLPE/SCT/PVC CABLES IEC 60502 & TNB Specifcation 6.35/11 (12) kV | ||||||||
| Phase conductor | ||||||||
| Nominal cross-sectional area | mm2 | 50 | 70 | 95 | 120 | 150 | l85 | 240 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 12 | 15 | 15 | 15 | 30 | 30 | |
| Nominal diameter of conductor | mm | 8.l | 9.7 | 11.5 | 12.9 | l4.3 | 16.1 | l8.4 |
| Nominal thickness of XLPE insulation | mm | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 |
| Metallic screening approx. thickness of copper tape | mm | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
| Nominal thickness of outer sheath | mm | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 |
| Nominal diameter over sheathing | mm | 23 | 24.6 | 26.3 | 27.8 | 29.2 | 30.9 | 33.3 |
| Max. dc resistance at 20°C | ohm/km | 0.64l | 0.443 | 0.32 | 0.253 | 0.206 | 0.l64 | 0.125 |
| Earth fault current carrying capacity of metallic screen at | ||||||||
| -1 second ( 1 Core ) | kA | 1.57 | 1.72 | 1.88 | 2.01 | 2.l4 | 2.3 | 2.52 |
| -3 seconds ( 1 Core ) | kA | 0.9 | 0.99 | l.08 | 1.16 | 1.23 | 1.33 | l.45 |
| Messenger – Galvanized steel wire | ||||||||
| Nominal cross-sectional area | mm2 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| Stranding | No./mm | 7/3.l5 | 7/3.l5 | 7/3.l5 | 7/3.l5 | 7/3.l5 | 7/3.l5 | 7/3.l5 |
| Direction of the outermost layer Righthand (Z) | ||||||||
| Overall diameter | mm | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 |
| Minimum breaking load | kg | 6270 | 6270 | 6270 | 6270 | 6270 | 6270 | 6270 |
| Completed cable | ||||||||
| Approx. overall diameter | mm | 55 | 59 | 62 | 65 | 67 | 71 | 75 |
| Approx. weight of cable | kg/km | 2540 | 2890 | 3300 | 3660 | 4040 | 4540 | 5290 |
| Packing length | m/drum | 500 | 500 | 500 | 500 | 500 | 500 | 500 |
| AERIAL BUNDLED CABLES AL/XLPE/SCT/PVC CABLES IEC 60502 & TNB Specifcation 12.7/22 (24) kV | ||||||||
| Phase conductor | ||||||||
| Nominal cross.sectional area | mm2 | 50 | 70 | 95 | 120 | 150 | l85 | 240 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 12 | 15 | 15 | 15 | 30 | 30 | |
| Nominal diameter of conductor | mm | 8.l | 9.7 | 11.5 | 12.9 | l4.3 | 16.1 | l8.4 |
| Nominal thickness of XLPE insulation | mm | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 |
| Metallic screening approx. thickness of copper tape | mm | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
| Nominal thickness of outer sheath | mm | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 |
| Nominal diameter over sheathing | mm | 27.2 | 28.8 | 30.5 | 32 | 33.4 | 35.1 | 37.5 |
| Max. dc resistance at 20°C | ohm/km | 0.64l | 0.443 | 0.32 | 0.253 | 0.206 | 0.l64 | 0.125 |
| Earth fault current carrying capacity of metallic screen at | ||||||||
| -1 second ( 1 Core ) | kA | 1.96 | 2.11 | 2.26 | 2.4 | 2.53 | 2.68 | 2.9 |
| -3 seconds ( 1 Core ) | kA | 1.13 | 1.21 | 1.31 | l.38 | l.46 | 1.55 | 1.67 |
| Messenger Galvanized steel wire | ||||||||
| Nominal cross-sectional area | mm2 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| Stranding | No./mm | 7/3.l5 | 7/3.l5 | 7/3.l5 | 7/3.l5 | 7/3.l5 | 7/3.l5 | 7/3.l5 |
| Direction of the outermost layer Right-hand (Z) | ||||||||
| Overall diameter | mm | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 |
| Minimum breaking load | kg | 6270 | 6270 | 6270 | 6270 | 6270 | 6270 | 6270 |
| Completed cable | ||||||||
| Approx. overall diameter | mm | 64 | 67 | 70 | 73 | 75 | 78 | 83 |
| Approx. weight of cable | kg/km | 3150 | 3540 | 3980 | 4360 | 4770 | 5300 | 6100 |
| Packing length | m/drum | 500 | 500 | 500 | 500 | 500 | 250 | 250 |
| AERIAL BUNDLED CABLES AL/XLPE/SCT/PVC CABLES IEC 60502 & TNB Specifcation 19/33 (36) kV | ||||||||
| Phase conductor | ||||||||
| Nominal cross-sectional area | mm2 | 50 | 70 | 95 | 120 | 150 | l85 | 240 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 12 | 15 | 15 | 15 | 30 | 30 | |
| Nominal diameter of conductor | mm | 8.l | 9.7 | 11.5 | 12.9 | l4.3 | 16.1 | l8.4 |
| Nominal thickness of XLPE insulation | mm | 8 | 8 | 8 | 8 | 8 | 8 | 8 |
| Metallic screening approx. thickness of copper tape | mm | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
| Nominal thickness of outer sheath | mm | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 |
| Nominal diameter over sheathing | mm | 32.2 | 33.8 | 35.5 | 37 | 38.4 | 40.l | 42.5 |
| Max. dc resistance at 20°C | ohm/km | 0.64l | 0.443 | 0.32 | 0.253 | 0.206 | 0.l64 | 0.125 |
| Earth fault current carrying capacity of metallic screen at | ||||||||
| -1 second ( 1 Core ) | kA | 2.4l | 2.56 | 2.72 | 2.86 | 2.99 | 3.l4 | 3.36 |
| -3 seconds ( 1 Core ) | kA | 1.39 | l.48 | 1.57 | 1.65 | 1.72 | l.8l | l.94 |
| Messenger Galvanized steel wire | ||||||||
| Nominal cross.sectional area | mm2 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| Stranding | No./mm | 7/3.l5 | 7/3.l5 | 7/3.l5 | 7/3.l5 | 7/3.l5 | 7/3.l5 | 7/3.l5 |
| Direction of the outermost layer | Righthand (Z) | |||||||
| Overall diameter | mm | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 |
| Minimum breaking load | kg | 6270 | 6270 | 6270 | 6270 | 6270 | 6270 | 6270 |
| Completed cable | ||||||||
| Approx. overall diameter | mm | 73 | 76 | 79 | 82 | 84 | 87 | 91 |
| Approx. weight of cable | kg/km | 3980 | 4400 | 4880 | 5300 | 5740 | 6310 | 7160 |
| Packing length | m/drum | 500 | 500 | 500 | 250 | 250 | 250 | 250 |
IEC 60502/DES/LV/ABC, 0.6/1kV ~ 30kV Aluminum/Polyethylene Insulated Overhead Bundled Cable, 🌍 Widely used internationally: in most countries in Africa, the Middle East, Southeast Asia, South Asia, South America, the Commonwealth of Independent States, and more.
| IEC 60502 & DES/LV/ABC 0.6/1 (1.2) kV Cables without street lighting | |||
| Phase conductor | |||
| Nominal cross-sectional area | mm2 | 25 | 35 |
| Number of cores | 3 | 3 | |
| Minimum number of wires | 6 | 6 | |
| Nominal insulation thickness | mm | l.4 | l.4 |
| Diameter of insulated core | mm | 8.9 | 9.9 |
| Max. dc resistance at 20°C | ohm/km | 1.2 | 0.868 |
| Minimum breaking load | kN | 3.5 | 4.9 |
| Current rating at still wind, ambient temperature = 30°C, conductor temperature = 75°C | A | 84 | 104 |
| Neutral Conductor | |||
| Nominal cross-sectional area | mm2 | 25 | 35 |
| Minimum number of wires | 6 | 6 | |
| Nominal insulation thickness | mm | l.4 | l.4 |
| Diameter of insulated core | mm | 8.9 | 9.9 |
| Max. dc resistance at 20°C | ohm/km | 1.2 | 0.868 |
| Minimum breaking load | kN | 3.5 | 4.9 |
| Completed cable | |||
| Approx. overall diameter | mm | 21.5 | 23.9 |
| Approx. weight of cable | kg/km | 420 | 550 |
| Packing length | m/drum | 1000 | 1000 |
| IEC 60502 & DES/LV/ABC 0.6/1 (1.2) kV Cables with street lighting | |||
| Phase conductor | |||
| Nominal cross-sectional area | mm2 | 120 | l85 |
| Number of cores | 3 | 3 | |
| Minimum number of wires | 15 | 30 | |
| Nominal insulation thickness | mm | 1.7 | 2.2 |
| Diameter of insulated core | mm | 17 | 21 |
| Max. dc resistance at 20°C | ohm/km | 0.253 | 0.164 |
| Minimum breaking load | kN | 16.8 | 25.9 |
| Current rating at still wind, ambient temperature = 30°C, conductor temperature = 75°C | A | 246 | 332 |
| Neutral conductor | |||
| Nominal cross-sectional area | mm2 | 120 | 185 |
| Minimum number of wires | 15 | 30 | |
| Nominal insulation thickness | mm | 1.7 | 2.2 |
| Diameter of insulated core | mm | 17 | 21 |
| Max. dc resistance at 20°C | ohm/km | 0.253 | 0.l64 |
| Minimum breaking load | kN | l6.8 | 25.9 |
| Street lighting conductor | |||
| Nominal cross-sectional area | mm2 | 25 | 25 |
| Minimum number of wires | 6 | 6 | |
| Nominal insulation thickness | mm | 1.4 | 1.4 |
| Diameter of insulated core | mm | 8.9 | 8.9 |
| Max. dc resistance at 20°C | ohm/km | 1.2 | 1.2 |
| Completed cable | |||
| Approx. overall diameter | mm | 43.8 | 50.7 |
| Approx. weight of cable | kg/km | 1,800 | 2700 |
| Packing length | m/drum | 500 | 500 |
BS 7870-5 0.6/1kV (low voltage),Aluminum/cross-linked polyethylene insulated overhead bundled cable 🇬🇧 UK, 🇮🇳 India, 🇵🇰 Pakistan, 🇳🇬 Nigeria, 🇿🇦 South Africa, 🇧🇩 Bangladesh, and more
| BS 7870-5 0.6/1 (1.2) kV Cables without street lighting Cables with street lighting | ||||||||||||
| Phase conductor | ||||||||||||
| Nominal cross-sectional area | mm2 | 25 | 35 | 50 | 70 | 95 | 25 | 35 | 50 | 70 | 95 | 120 |
| Number of cores | 1 | 1 | 1 | 1 | 1 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 12 | 15 | 6 | 6 | 6 | 12 | 15 | 15 | |
| Nominal insulation thickness | mm | 1.3 | 1.3 | 1.5 | 1.5 | 1.7 | 1.3 | 1.3 | 1.5 | 1.5 | 1.7 | 1.7 |
| Diameter of insulated core | mm | 8.8 | 9.8 | 11.5 | 13.2 | 15.3 | 8.8 | 9.8 | 11.5 | 13.2 | 15.3 | 16.8 |
| Max. dc resistance at 20°C | ohm/km | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 |
| Current rating at still wind ambient temperature = 30°C Conductor temperature = 75°C | A | 84 | 104 | 129 | 167 | 209 | 84 | 104 | 129 | 167 | 209 | 283 |
| Neutral conductor | ||||||||||||
| Nominal cross-sectional area | mm2 | 25 | 35 | 50 | 70 | 95 | 25 | 35 | 50 | 70 | 95 | 120 |
| Minimum number of wires | 6 | 6 | 6 | 12 | 15 | 6 | 6 | 6 | 12 | 15 | 15 | |
| Nominal insulation thickness | mm | 1.3 | 1.3 | 1.5 | 1.5 | 1.7 | 1.3 | 1.3 | 1.5 | 1.5 | 1.7 | 1.7 |
| Diameter of insulated core | mm | 8.8 | 9.8 | 11.5 | 13.2 | 15.3 | 8.8 | 9.8 | 11.5 | 13.2 | 15.3 | 16.8 |
| Max. dc resistance at 20°C | ohm/km | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 |
| Completed cable | ||||||||||||
| Minimum breaking load | kN | 8.2 | 11.2 | 15.2 | 22 | 30.6 | l6.4 | 22.4 | 30.4 | 44 | 61.2 | 77.6 |
| Approx. overall diameter | mm | 17.6 | 19.6 | 23 | 26.4 | 30.6 | 21.2 | 23.7 | 27.8 | 31.9 | 36.9 | 40.6 |
| Approx. weight of cable | kg/km | 210 | 270 | 360 | 500 | 680 | 4l0 | 550 | 730 | 1000 | 1370 | 1690 |
| Packing length | m/drum | 1000 | 1000 | 1000 | 1000 | 500 | 1000 | 1000 | 1000 | 1000 | 500 | 500 |
| BS 7870-5 0.6/1 (1.2) kV Cables without street lighting Cables with street lighting | ||||
| Phase conductor | ||||
| Nominal cross-sectional area | mm2 | 50 | 70 | 95 |
| Number of cores | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 12 | 15 | |
| Nominal insulation thickness | mm | 1.5 | 1.5 | 1.7 |
| Diameter of insulated core | mm | 11.5 | 13.2 | 15.3 |
| Max. dc resistance at 20°C | ohm/km | 0.641 | 0.443 | 0.32 |
| Current rating at still wind, ambient | A | 129 | 167 | 209 |
| temperature = 30°C conductor temperature = 75°C | ||||
| Neutral conductor | ||||
| Nominal cross-sectional area | mm2 | 50 | 70 | 95 |
| Minimum number of wires | 6 | 12 | 15 | |
| Nominal insulation thickness | mm | 1.5 | 1.5 | 1.7 |
| Diameter of insulated core | mm | 11.5 | 11.5 | 15.3 |
| Max. dc resistance at 20°C | ohm/km | 0.641 | 0.443 | 0.32 |
| Street lighting conductor | ||||
| Nominal cross-sectional area | mm2 | 25 | 25 | 25 |
| Minimum number of wires | 6 | 6 | 6 | |
| Nominal insulation thickness | mm | 1.3 | 1.3 | 1.3 |
| Diameter of insulated core | mm | 8.8 | 8.8 | 8.8 |
| Max. dc resistance at 20°C | ohm/km | 1.2 | 1.2 | 1.2 |
| Completed cable | ||||
| Minimum breaking load | kN | 34.5 | 48.1 | 65.3 |
| Approx. overall diameter | mm | 29.8 | 33.6 | 38.2 |
| Approx. weight of cable | kg/km | 830 | 1100 | l470 |
| Packing length | m/drum | 1000 | 1000 | 500 |