LV & MV Aerial Bundle Cable (ABC Cable)

Home > Products > Aerial Bunch Cable > LV & MV Aerial Bundle Cable (ABC Cable)

LV & MV Aerial Bundle Cable (ABC Cable)

LV & MV ABC cables – safe, compact, and easy to install overhead.

Reliable bundled conductors for 0.6kV to 35kV power distribution.

Weather-resistant ABC cable for aerial low and medium voltage lines.

Reduce outages and improve safety with ABC overhead solutions.

Factory-supplied LV/MV ABC cable – IEC, BS, NFC compliant.

Application

LV & MV Aerial Bundled Cable (ABC Cable) is an overhead power distribution solution designed for 0.6/1kV up to 20–35kV systems, offering enhanced safety, reliability, and installation flexibility. Unlike traditional bare conductors, ABC cables feature fully insulated aluminum or aluminum alloy phase conductors, bundled with a neutral messenger or supporting core, providing excellent protection against accidental contact, short circuits, and environmental interference.

Low Voltage ABC cables are commonly used in residential and urban networks for service drops and public lighting, while Medium Voltage ABC cables are ideal for rural electrification, forested areas, coastal zones, and regions prone to storms or corrosion—where undergrounding is costly or impractical.

The insulation is typically made of UV-resistant XLPE or HDPE, ensuring long-term outdoor performance under sunlight, heat, and moisture. Constructions may include bare or insulated messengers, streetlight conductors, and water-blocking layers as needed.

These cables are manufactured to meet IEC 60502, NFC 33-209, AS/NZS 3560.1, BS 7870, and other regional standards, supporting global utility and infrastructure projects.

ABC cables offer a compact, safe, and cost-effective alternative to bare conductors in overhead low and medium voltage power systems.

Specifications

StandardVoltage Range & ConstructionTypical Applications & Advantages
BS 7870 / BS 7870-5– 0.6/1 kV LV ABC- Hard-drawn aluminum conductors, XLPE insulation, twisted bundle with neutral/messenger– Used in UK urban networks, dense housing- Emphasizes electrical safety + easy maintenance
AS/NZS 3560.1 / 3599.1– 0.6/1 kV (3560.1), 6.35/11–19/33 kV (3599.1/2)- Aluminum or ACSR cores, UV-stabilized XLPE– Widely applied across Australia/NZ for both LV and MV- Designed for bushfire-prone regions
NF C 33-209– LV ABC 0.6/1 kV- All conductors fully insulated incl. neutral- Concentric or star-quad layout– Standard in France, West Africa- Touch-safe, no exposed metal, ideal near vegetation
HD 626 S1– Covers 0.6/1 kV and MV aerial cables in EU under harmonized structure- XLPE/PE insulation, EU colors– Used in pan-European projects- Supports standardized installation distances and accessories
NFC 33-226– MV CIS (twisted pair) aerial versions- XLPE insulation with screened conductors– Common in French-speaking Africa, often for medium-voltage rural or industrial feeders
SANS 1713 (South Africa)– 0.6/1 kV ABC- Aluminum cores, full XLPE insulation, UV/heat resistant– Adapted for African climate extremes- Anti-theft, robust, ideal for informal areas



Parameter

ELAND PART
NUMBER
NUMBER
CORES
NOMINAL
CROSS SECTIONAL AREA
mm2
NOVNAL
OVERALL
DIAMETER
mm
NOMINAL
WEIGHT
KG/KM
MINIMUM
D RE AKING
LOAD
KN
MAXIMUM
CONDUCTOR
RESISTANCE
 /km
CURRENT
RATENG
A
BS 7870
C1AD1016116874251.9172
C1AD1025125910641200107
C1AD103513510.51385.50.868132
C1AD105015011.818280.641165
C1AD10701701325210.70.443205
C1AD109519515.433313.7320240
C1A0112011201740818.6253290
C1A0115011501950223.2206334
C1A0118511852161128.70.164389
C1AD124012402480137.20.125467
C1A0201621615.6147251.9172
C1A020252251820841.2107
C1A0203523520277550.868132
C1A0205025023.536180.641165
C1A0207027025.450510.70.443205
C1A0209529530.366613.7320240
C1A02150215038100423.2206334
C1AD401641618.8286251.9172
C1A0402542521.243041200107
C1A0403543524.15535.50.868132
C1AD405045027.874680.641165
C1AD407047031.8100910.70.443205
C1A0409549537.8133213.7320240
C1AD4120412054.4163218.6253290
C1A04050/1X254+150+253198148.0/4.00.641/1200165/107
C1A04050/1X354+150+353198458.5/550.641/0.868165/132
C1A04070/1X254+170+25360110510.7/4.00.443/1.200205/107
C1A04070/2X254+270+25+25400121710.7/4.00.443/1.200205/107
C1A04095/1X254+195+25418143813.7/4.00.320/1.200240/107
C1A04095/2X254+295+25+25420154413.7/4.00.320/1.200240/107
C1A04120/254+1120+25590205018.6/4.00.253/1.200290/107

 

VIMIEINSIUNSNOMINAL CROSS
SECTIONAL AREA
mm
MAX DC RESISTANCE
OF CONDUCTOR IN BUNDLE AT 200C
ohms/km
CURRENT CARRYING CAPACITY
IN FREE AIR                 Amps
MNIMUM TENSILE STRENGTH OF CONDUCTOR
KN
BS 7870-5
B7A020252251.39.710.2200251.21074.1
B7A020352351.310.711.2266350.8681325.6
B7A020502501512.112.6374500.6411657.6
B7A020702701.513814.3506700.44320511
B7A020952951.716.116.6681950.3225815.3
B7A0212021201.717.618.18161200.253300194
B7A03025325139.710.2318    
B7A030353351310.711.2414    
B7A030503501.512.112.6545    
B7A030703701513814.3756    
B7A030953951.716.116.6999    
B7A0312031201.717.618.11224    
B7A05025525139710.2530    
B7A050355351310.711.2690    
B7A050505501512.112.6910    
B7A050705701513.814.31260    
B7A050955951.716.116.61665    
B7A0512051201.717.618.12040    

 

ELAND PART
NUMBER
NUMBER
CORES
NOMINAL
CROSS SECTIONAL
AREA
mm2
NOVNAL
OVERALL
DIAMETER
mm
NOMINAL
WEIGHT
KG/KM
MINMUM
BREAKING
LOAD
KN
MAXIMUM
CONDUCTOR
RESISTANCE
Ω/km
CURRENT RATING A
AS-NZS 3560 Part 1
C1E02016216151404A1.9178
C1E0202522517.621071.2105
C1E0203523519.62709.80.868125
C1E0205025022.837011.40.641150
C1E0209529530.668015.30.32230
C1E03025325193108.81.297
C1E0303533521.14109.80.868120
C1E0305035024.655011.40.641140
C1E0401641618.12908.81.9174
C1E0402542521.2410141.297
C1E0403543523.755019.60.868120
C1E0405045027.5740280.641140
C1E0407047031.9100039.20.443175
C1E0409549536.9137053.20.32215
C1E04120412040.6169067.20.253250
C1E04150415043.92020840.206280

 

AS/NZS 3599.1 MV Aerial Bundled cables
6.35/11kV & 12.7/22kV Al/XlPE /HDPE Non-Screened Cables ABC Cable-AS/NZS 3599.1 Standard
number of cores x nominal cross sectionNominal conductor diameterNominal insulation thicknessNominal insulation screen thicknessNominal sheath thicknessAAAC/1120 support conductor sizeNominal overall diameterWeightContinuous current rating, A
        Still air1m/s wind2m/s wind
mm^2mmmmmmmmNo/mmmmkg/kmAAA
6.35/11kV
3X356.93.40.81.27/4.7552.41370110155185
3X508.13.40.81.27/4.7554.61530130185225
3X709.73.40.81.27/4.7557.81790160235280
3X9511.43.40.81.27/4.7561.32100195285345
3X12012.83.40.81.219/3.5067.32540230335405
3X15014.23.40.81.219/3.5070.12840255380460
3X18515.73.40.81.219/3.5073.13190295440530
12.7/22kV
3X356.95.50.81.27/4.75611780110155180
3X508.15.50.81.27/4.7563.31970130185220
3X709.75.50.81.27/4.7566.52260160230275
3X9511.45.50.81.27/4.7569.92600195285335
3X12012.85.50.81.219/3.5075.93070225330395
3X15014.25.50.81.219/3.5078.73390255375450
3X18515.75.50.81.219/3.5081.73760290435520
6.35/11kV & 12.7/22kV AL/XLPE /CWS/HDPE Screened Cables ABC Cable-AS/NZS 3599.1 Standard
Number of Cores x Nominal Cross SectionDiameter of ConductorThickness of InsulationThickness of Insulation ScreenCopper Wire Screen StrandingThickness of SheathGalvanized Steel Wire StrandingNominal Sectional AreaBreaking Load
No.mm^2mmmmmmNo.mmmmNo.mmmm^2KN
6.35/11 kV Light Duty Screen
3X356.93.40.825/0.851.87/2.0054.11820
3X356.93.40.825/0.851.819/2.0058.12130
3X508.13.40.825/0.851.819/2.0060.42300
3X709.73.40.825/0.851.819/2.0063.62570
3X9511.43.40.825/0.851.819/2.00672900
3X12012.83.40.825/0.851.819/2.0069.83190
3X15014.23.40.825/0.851.919/2.00733530
3X18515.73.40.825/0.851.919/2.00763890
6.35/11 kV Heavy Duty Screen
3X356.93.40.840/0.851.87/2.0054.12050
3X356.93.40.840/0.851.819/2.0058.12360
3X508.13.40.823/1.351.819/2.0062.42820
3X709.73.40.832/1.351.819/2.0065.63440
3X9511.43.40.839/1.351.819/2.00694030
3X12012.83.40.839/1.351.819/2.0071.84320
3X15014.23.40.839/1.351.919/2.00754670
3X18515.73.40.839/1.351.919/2.00785020
12.7/22 kV Light Duty Screen
3X356.95.50.825/0.851.87/2.0062.72280
3X356.95.50.825/0.851.819/2.0066.72580
3X508.15.50.825/0.851.819/2.00692780
3X709.75.50.825/0.851.919/2.0072.63110
3X9511.45.50.825/0.851.919/2.00763460
3X12012.85.50.825/0.85219/2.0079.23810
3X15014.25.5125/0.85219/2.0082.84230
3X18515.75.5125/0.852.119/2.0086.24650
12.7/22 kV Heavy Duty Screen
3X356.95.50.840/0.851.87/2.0062.72510
3X356.95.50.840/0.851.819/2.0066.72810
3X508.15.50.823/1.351.819/2.00713300
3X709.75.50.832/1.351.919/2.0074.63970
3X9511.45.50.839/1.351.919/2.00784600
3X12012.85.50.839/1.35219/2.0081.24950
3X15014.25.5139/1.35219/2.0084.85360
3X18515.75.5139/1.352.119/2.0088.25790
AS/NZS 3599.2 HV XLPE Insulated ABc Cable 6.35/1lkV & 12.7/22kV
11kV 22kV XLPE Non Metallic Screened Aerial Cable Physical Data 
Nominal conductor areaNominal conductor diameterAverage insulation thicknessNominal diameter over insulationAverage insulation screen thicknessNominal diameter over coreAAAC/1 1 20 support conductorNominal overall diameterApprox mass 
mm2mmmmmmmmmmSize no/mmDiameter mmmmkg/km 
6.35/11kV 
356.93.414.9117.17/4.7514.348.41170 
508.13.416118.27/4.7514.350.71320 
709.63.417.6119.87/4.7514.353.91560 
9511.43.419.3121.57/4.7514.357.31860 
12012.83.420.7122.919/3.5017.563.32280 
15014.23.422.1124.319/3.5017.566.22570 
18515.73.423.6125.819/3.5017.569.22890 
12.7/22kV 
356.95.519.2121.47/4.7514.357.11540 
508.15.520.3122.57/4.7514.359.31710 
709.65.521.9124.17/4.7514.362.51990 
9511.45.523.6125.87/4.7514.3662310 
12012.85.525127.219/3.5017.5722760 
15014.25.526.41.128.819/3.5017.575.23100 
18515.75.527.91.130.319/3.5017.578.23460 
11kV 22kV XLPE Insulated Metallic Screened 11kV
Part No.Nominal conductor areaNominal conductor diameterAverage insulation screen thicknessCopper wire screen strandingNominal diameter over screenAverage sheath thicknessNominal diameter over sheathGalvanised steel catenary strandingNominal overall diameterApprox. mass
mm2mmmmno/mmmmmmmmno/mmmmkg/km
AERMV3X35SCN11kV356.90.824/0.8519.21.823.519/2/0057.12060
AERMV3X50SCN11kV508.10.824/0.8520.41.824.719/2/0059.32230
AERMV3X70SCN11kV709.60.824/0.85221.826.319/2/0062.52500
AERMV3X95SCN11kV9511.40.824/0.8523.71.82819/2/00662820
AERMV3X120SCN11kV12012.80.824/0.8525.11.829.419/2/0068.83100
AERMV3X150SCN11kV15014.20.824/0.8526.51.93119/2/00723440
AERMV3X185SCN11kV18515.70.824/0.85281.932.519/2/00753800
ELAND PART
NUMBER
NUMBER
CORES
NOMINAL
CROSS SECTIONAL AREA
mm2
NOMINAL
OVERALL
DIAMETER
mm
NOMINAL
WEIGHT
KG/KM
MINIMUM BRE AKING LOAD
KN
MAXIMUM
CONDUCTOR
RESISTANCE
0/km
CURRENT RATING
NF C33-209
C1D0201021012.8931.53.0838
C1D0201621614.81292.31.9172
C1D02016/2X1.52+216/1514.81762.31.910/12.10072
C1D02025225182023.81.2107
C1D02025/2X1.52+225/15182493.81.200/12.100107
C1D0203523520.82695.20.868132
C1D02035/2X1.52+235/1.520.83165.20.868/12.100132
C1D0205025023.43527.60.641165
C1D02050/2X1.52+250/1.523.43997.60.641/12.100165
C1D0401041015.41831.53.0838
C1D0401641617.82572.31.9172
C1D04016/2X1.54+216/1517.83042.31.910/12.10072
C1D0402542521.74043.81.2107
C1D04025/2X1.54+225/1521.74513.81.200/12.100107
C1D0403543525.15395.20.868132
C1D04035/2X1.54+235/1.525.15865.20.868/12.100132
C1D01054/3251+354.6/2521.75073.80.630/1.200107
C1D01054/3251161+3+154.6/25/1624.35733.8/2.30.630/1.200/1.910107/72
C1D01054/3252161+3+254.6/25/1629.76393.8/2.30.630/1.200/1.910107/72
C1D01054/3253161+3+354.6/25/1631.17053.8/2.30.630/1.200/1.910107/72
C1D01054/3351+354.6/3525.16155.20.630/0.868132
C1D01054/3351161+3+154.6/35/1628.16805.2/2.30.630/0.868/1.910132/72
C1D01054/3352161+3+254.6/35/1634.37485.2/2.30.630/0.868/1.910132/72
C1D01054/3353161+3+354.6/35/1635.98145.2/2.30.630/0.868/1.910132/72
C1D01054/3351251+3+154.6/35/2528.17145.2/3.80.630/0.868/1.200132/107
C1D01054/3501+354.6/5028.27417.60.630/0.641165
C1D01054/3501161+3+154.6/35/2531.68067.6/2.30.630/0.641/1.910165/72
C1D01054/3502161+3+254.6/35/2538.68757.6/2.30.630/0.641/1.910165/72
C1D01054/3503161+3+354.6/35/2540.49407.6/2.30.630/0.641/1.910165/72
C1D01054/3501251+3+154.6/50/2531.68417.6/3.80.630/0.641/1.200165/107
C1D01054/3701+354.6/703395010.20.630/0.443205
C1D01054/3701161+3+154.6/70/1637101410.2/2.30.630/0.443/1.910205/72
C1D01054/3702161+3+254.6/70/1645.2108310.2/2.30.630/0.443/1.910205/72
C1D01054/3703161+3+354.6/70/1647.3114810.2/2.30.630/0.443/1.910205/72
C1D01054/3701251+3+154.6/70/2537104810.2/3.80.630/0.443/1.200205/107
C1D01054/3702251+3+254.6/70/2545.2115010.2/3.80.630/0.443/1.200205/107
C1D01054/3703251+3+354.6/70/2547.3125010.2/3.80.630/0.443/1.200205/107
C1D01054/3951+354.6/9537.4117613.50.630/0.320240
C1D01054/3951161+3+154.6/95/1641.9124313.5/2.30.630/0.320/1.910240/72

 

NFC 33-226 Cable HTA CIS Torsadé Souterrain 12/20(24)kV 18/30 (36) KV
NF C33-226 12/20 kVouterMax DC Resist.Max. tensileBending radiusWeight
Section mmDiameter/kmstrength(mm)Approx.
 (mm) (daN) (kg/km)
single core cables
50290.641150377754700
95320.32285416832950
150320.2064504168321000
24036.50.1257204759501400
400420.078120054610921950
63052.50.047189068313653100
1200660.025360o85817165200
bunched cables
3x1x5062.50.6414503777542100
3x1x95690.328554168322800
3x1x150690.20613504168323050
3x1x24078.50.12521604759504150
3x1x400900.078360054610925800

 

ELAND PART
NUMBER
NUMBER
CORES
NOMINAL
CROSS SECTIONAL AREA
mm2
NOMNAL
OVERALL
DIAMETER
mm
NOMINAL WEIGHT
KG/KM
MINIMUM
BREAKING
LOAD
KN
MAXIMUM
CONDUCTOR
RESISTANCE
Ω/km
CURRENT RATING
HD 626 S1
C1C020162167214719101.912.5
C1C02025225107208120012004
C1C020352351322770.8680.8685.5
C1C020502501653610.6410.6418
C1C040164167228619101.912.5
C1C04025425107430120012004
C1C040354351325530.8680.8685.5
C1C040504501657460.6410.6418
C1C0407047020510090.4430.44310.7
C1C0409549524013320.320.3213.7
C1C04120412029016320.2530.25318.6
C1C04035/1X354+135/35132/1326940868/0.8680.868/0.8685.5/5.5
C1C04050/1X254+150/25165/1078140.641/1.2000.641/1,2008.0/4.0
C1C04050/1X354+150/35165/1328450.641/0.8680.641/0.8688.5/5.5
C1C04070/1X254+170/25205/10711050.443/1.2000.443/1.20010.7/4.0
C1C04070/2X254+270/25/25205/10712170.443/1.2000.443/1.20010.7/4.0
C1C04070/1X354+270/35205/13211500.443/0.8680.443/0.868107/5.5
C1C04070/2X354+270/35/35205/13212890.443/0.8680.443/0.868107/5.5
C1C04095/1X254+195/25240/10714380.320/1.2000.320/1.20013.7/4.0
C1C04095/1X354+195/35240/13214670320/08680.320/0.86813.7/5.5
C1C04095/2X254+295/25/25240/10715440.320/1.2000.320/1.20013.7/4.0

 

SANS 1713 MV ABC Wire
6.6kV ABC Cable Specification
Phase Core
Conductor sizemm2 nom35507095120150185
Conductor diametermm app.7.158.259.9511.813.114.815.95
Insulation diametermm app.15.416.518.220.121.422.724.2
Core sheath diametermm app.20.521.623.525.526.828.129.9
Catenary (Support Core)
Conductor sizemm2 nom50505050707070
Conductor diametermm app.999910.810.810.8
Insulation diametermm app.11.511.511.511.513.313.313.3
Maximum tensile strength and pulling force of catenarykN26262626373737
Cable
Cable diametermm app.44475155586165
Cable masskg/m app.2.052.242.63.013.513.854.33
Gross mass (500m)kg app.9159731,0791,2041,3541,4541,599
Bending radiusmm min.636669720776841880926
Current rating
In airAmps150185230280325370430
Resistance
dc @ 20°CW/km max0.8680.6410.4430.320.2530.2060.164
ac @ 90°CW /km max1.1130.8220.5680.4110.3250.2650.211
ReactanceW /km0.1360.1240.1210.1140.1110.1060.103
ImpedanceW /km1.1210.8320.5810.4260.3420.2840.233
Short circuit ratings
SymmetricalkA (1 sec)345.8810.212.515.7
Earth faultkA (1 sec)1.51.61.71.922.12.3

 

11kv ABC Cable Specification
Phase Core
Conductor sizemm2 nom35507095120150185
Conductor diametermm app.7.158.259.9511.813.114.816.35
Insulation diametermm app.17.318.420.121.923.224.526.1
Core sheath diametermm app.22.523.625.327.428.730.231.7
Catenary (Support Core)
Conductor sizemm2 nom50505050707070
Conductor diametermm app.999910.810.810.8
Insulation diametermm app.11.511.511.511.513.313.313.3
Maximum tensile strength and pulling force of catenarykN26262626373737
Cable
Cable diametermm app.49515559626569
Cable masskg/m app.2.312.522.853.283.613.994.43
Gross mass (500m)kg app.9931,0551,1551,2851,3821,4961,628
Bending radiusmm min.691724775831896935981
Current rating
In airAmps150185230280325370430
Resistance
dc @ 20°CW/km max0.8680.6410.4430.320.2530.2060.164
ac @ 90°CW /km max1.1130.8220.5680.4110.3250.2650.211
ReactanceW /km0.1360.1240.1210.1140.1110.1060.103
ImpedanceW /km1.1210.8320.5810.4260.3420.2840.233
Short circuit ratings
SymmetricalkA (1 sec)345.8810.212.515.7
Earth faultkA (1 sec)1.51.61.71.922.12.3
22kV ABC Cable Specification
Phase Core
Conductor sizemm2 nom35507095120150185
Conductor diametermm app.7.158.259.9511.813.114.816.35
Insulation diametermm app.21.622.724.426.227.529.230.8
Core Sheath diametermm app.2728.13031.933.435.136.8
Catenary (Support Core)
Conductor sizemm2 nom50505050707070
Conductor diametermm app.999910.810.810.8
Insulation diametermm app.11.511.511.511.513.313.313.3
Maximum Tensile Strength and Pulling force of CatenarykN26262626373737
Cable
Cable diametermm app.58616569727680
Cable masskg/m app.2.963.193.614.054.635.065.61
Gross mass (500m)kg app.1 1881 2571 3831 5141 6901 8191 984
Bending radiusmm min.821854905960102510761123
Current rating
In airAmps150185230280325370430
Resistance
dc @ 20°CW/km max0.8680.6410.4430.320.2530.2060.164
ac @ 90°CW /km max1.1130.8220.5680.4110.3250.2650.211
ReactanceW /km0.1360.1240.1210.1140.1110.1060.103
ImpedanceW /km1.1210.8320.5810.4260.3420.2840.233
Short circuit ratings
SymmetricalkA (1sec)345.8810.212.515.7
Earth faultkA (1sec)1.51.61.71.922.12.3
33kV ABC Cable Specification
Phase Core
Conductor sizemm2 nom507095120150185
Conductor diametermm app.8.259.9511.813.114.816.35
Insulation diametermm app.27.829.531432.73435.5
Core Sheath diametermm app.33.735.437.438.740.241.8
Catenary (Support Core)
Conductor sizemm2 nom505050707070
Conductor diametermm app.99910.8|10.8010.8
Insulation diametermm app.11.511.511.513.313.313.3
Maximum Tensile Strength and Pulling force of CatenarykN262626373737
Cable
Cable diametermm app.737681848790
Cable masskg/m app.4.124.535.065.375.826.33
Gross mass (500m)kg app.1,5351,6581,8191,9102,0462,200
Bending radiusmm min.1007105811141179|12181264
Current rating
In airAmps185230280325370430
Resistance
dc @ 20°CW/km max0.6410.4430.320.2530.2060.164
ac @ 90°CW/km max0.8220.5680.4110.3250.2650.211
ReactanceW /km0.1240.1210.1140.1110.1060.103
ImpedanceW /km0.8320.5810.4260.3420.2840.233
Short circuit ratings
SymmetricalkA (1 sec)45.8810.212.515.7
Earth faultkA (1 sec)1.61.71.922.12.3
Duplex Service Drop – Aluminum Conductors
Code WordPhase ConductorBare Neutral MessengerApprox.  Diameter of CableApprox. Weight
SizeNo. of wiresNominal Insulation ThicknessSizeNo. of WiresDiameter of Wires
AWG or KcmilNo.mmAWG or KcmilNo.mmmmkg/km
AAC/XLPE+AAC
Pekingese611.1461/71.5611.192
Collie671.1461/71.5611.594
Cocker671.5261/71.5612.2100
Dachshund411.1441/71.9613.4140
Spaniel471.1441/71.9613.9143
Cairn471.5241/71.9614.6150
Doberman271.1421/72.4716.9220
Airedale1191.5211/72.7819.6280
Basset1/071.521/01/73.1221.8355
Malemute1/0191.521/01/73.1221.6350
AAC/XLPE+AAAC
Chihuahua611.1430.581/71.6811.498
Vizsla671.1430.581/71.6811.8100
Harrier411.1448.691/72.1213.8149
Whippet471.1448.691/72.1214.4154
Schnauzer271.1477.471/72.6717.5235
Afghan1/071.52123.31/73.3722.5378
Heeler1/0191.52123.31/73.3722.3375
AAC/XLPE+ACSR
Setter611.1466/11.6811.4109
Shepherd671.1466/11.6811.8112
Retriever671.5266/11.6812.6119
Eskimo411.1446/12.1213.8166
Terrier471.1446/12.1214.4170
Yorkshire471.5246/12.1215.1180
Chow271.1426/12.6717.5262
Labrador1191.5216/1320.2339
Bloodhound1/071.521/06/13.3722.5425
Bull1/0191.521/06/13.3722.3422
Triplex Service Drop – Aluminum Conductors
Code WordPhase ConductorBare Neutral MessengerApprox.  Diameter of CableApprox. Weight
SizeNo. of WiresNominal Insulation ThicknessSizeNo. of WiresDiameter of Wires
AWG or KcmilNo.mmAWG or KcmilNo.mmmmkg/km
AAC/XLPE+AAC
Haiotis611.1461/71.5612.6148
Pike670.7661/71.5612.1139
Patella671.1461/71.5613.2154
Albus671.5261/71.5614.3170
Fusus411.1441/71.9615221
Limpet471.1461/71.5614.9208
Oyster471.1441/71.9615.8230
Argo471.5241/71.9616.9249
Clam271.1421/72.4719347
Thia271.5221/72.4720.1370
Mussel271.1441/71.9617.9312
Pyrula171.5211/72.7822.4465
Hyas1191.5211/72.7822.2450
Snail1/071.5221/72.4723.2517
Murex1/071.521/01/73.1224.6572
Purpura1/0191.521/01/73.1224.4554
Nassa2/071.522/01/73.527.1706
Trophon2/0191.522/01/73.526.8684
Quahog3/072.033/01/73.9331.3920
Ione3/0192.033/01/73.9331892
Melita3/0191.523/01/192.3929.7845
Coquina4/071.524/01/74.42331082
Tusk4/072.034/01/74.4234.51134
Apus4/0192.034/01/74.4234.11098
Portunus4/0192.034/01/192.6834.21098
Chiton266.8192.03266.81/193.0138.41379
Alverno300372.034/01/192.6837.81386
Nannynose336.4192.03336.41/193.3842.41707
AAC/XLPE+AAAC
Minex611.1430.581/71.6812.8154
Hippa671.1430.581/71.6813.4160
Code WordPhase ConductorBare Neutral MessengerApprox.  Diameter of CableApprox. Weight
SizeNo. of WiresNominal Insulation ThicknessSizeNo. of WiresDiameter of Wires
AWG or KcmilNo.mmAWG or KcmilNo.mmmmkg/km
AAC/XLPE+AAAC
Artemia411.1430.581/71.6814.4205
Crad471.1430.581/71.6815.2214
Prawn411.1448.691/72.1215.3231
Barnacle471.1448.691/72.1216.1239
Solaster271.1448.691/72.1218.2322
Pagurus271.5248.691/72.1219.3345
Shrimp271.1477.471/72.6719.4362
Lobster271.5277.471/72.6720.5385
Sanderab1/071.5277.471/72.6723.6532
Echinus1/0191.5277.471/72.6723.4514
Gammarus1/071.52123.31/73.3725.1597
Leda1/0191.52123.31/73.3724.9579
Crayfish2/071.5297.651/7326655
Sipho2/0191.5297.651/7325.7633
Abalone2/071.52123.31/73.3726.8691
Spirula2/0191.52123.31/73.3726.5669
Dungenese2/071.52155.41/73.7827.7736
Cyclops2/0191.52155.41/73.7827.4714
Slug3/071.52123.31/73.3728.6809
Fulgur3/0191.52123.31/73.3728.4781
Balanus3/0192.03123.31/73.3729.8828
Stonecrab3/071.52195.71/74.2530.5904
Flustra3/0191.52195.71/74.2530.3884
Crisia3/0192.03195.71/74.2531.7931
Squid4/071.52155.41/73.7831.61001
Arca4/0191.52155.41/73.7831.3966
Bugula4/0192.03155.41/73.7832.71018
Kingcrab4/071.52246.91/74.7733.81131
Lepas4/0191.52246.91/74.7733.41096
Cassis4/0192.03246.91/74.7734.91147
Cyphoma4/071.52123.31/73.3730.8957
Mitre4/0191.52123.31/73.3730.4921
Argonaut336.4192.03246.91/74.7740.51579
Nautilis336.4192.03394.51/193.6643.41787
Code WordPhase ConductorBare Neutral MessengerApprox.  Diameter of CableApprox. Weight
SizeNo. of WiresNominal Insulation ThicknessSizeNo. of wiresDiameter of Wires
AWG or KcmilNo.mmAWG or KcmilNo.mmmmkg/km
AAC/XLPE+ACSR
Paludina611.1466/11.6812.8165
Voluta671.1466/11.6813.4171
Bolma671.5266/11.6814.5188
Scallop411.1466/11.6814.4217
Strombus471.1466/11.6815.1225
Carnea471.5266/11.6816.2244
Whelk411.1446/12.1215.3249
Periwinkle471.1446/12.1216.1257
Calma471.5246/12.1217.2277
Cockle271.1446/12.1218.2340
Gebia271.5246/12.1219.3363
Conch271.1426/12.6719.4391
Uca271.5226/12.6720.5414
Vermeths171.5216/1322.9520
Atya1191.5216/1322.6506
Janthina1/071.5226/12.6723.6561
Ranella1/0191.5226/12.6723.4543
Neritina1/071.521/06/13.3725.1642
Cenia1/0191.521/06/13.3724.9624
Cavolinia2/071.5216/1326691
Clio2/0191.5216/1325.7669
Runcina2/071.522/06/13.7827.7794
Triton2/0191.522/06/13.7827.4772
Sanddollar3/071.521/06/13.3728.6854
Aega3/0191.521/06/13.3728.4827
Pisa3/0192.031/06/13.3729.8874
Cherrystone3/071.523/06/14.2530.5983
Mursia3/0191.523/06/14.2530.3956
Mysis3/0192.033/06/14.2531.71003
Cuttlefish4/071.522/06/13.7831.71059
Code WordPhase ConductorBare Neutral MessengerApprox.  Diameter of CableApprox. Weight
SizeNo. of WiresNominal Insulation ThicknessSizeNo. of wiresDiameter of Wires
AWG or KcmilNo.mmAWG or KcmilNo.mmmmkg/km
AAC/XLPE+ACSR
Cerapus4/0191.522/06/13.7831.31024
Nepatus4/0192.032/06/13.7832.71075
Razor4/071.524/06/14.7733.81222
Zuzara4/0191.524/06/14.7733.41187
Alima4/0192.034/06/14.7734.91238
Callista266.8192.033/06/14.2536.71350
Dosinia266.8192.03266.81/183.0938.71438
Cowry336.4192.034/06/14.7740.51670
Limpet336.4192.03336.41/183.4742.71782
Quadruplex Service Drop  
Code WordPhase ConductorBare Neutral MessengerApprox.  Diameter of CableApprox. Weight
SizeNo. of WiresNominal Insulation ThicknessSizeNo. of wiresDiameter of Wires
AWG or KcmilNo.mmAWG or KcmilNo.mmmmkg/km
AAC/XLPE+AAC
Quarter611.1461/71.5614.4203
Clydesdate411.1441/71.9617.1302
Pinto471.1441/71.9618.1315
Mustang271.1421/72.4721.7474
Shire1191.5211/72.7825.4616
Libyan1/071.521/01/73.1228.2784
Criollo1/0191.521/01/73.1227.9757
Orloff2/071.522/01/73.530.9965
Percheron2/0191.522/01/73.530.6931
Mongolian3/071.523/01/73.9334.11190
Hanoverian3/0191.523/01/192.3933.81148
Singlefoot4/071.524/01/74.4237.61474
Oldenburg4/0191.524/01/192.6837.21421
Lippizaner336.4192.03336.41/193.3848.32322
AAC/XLPE+AAAC
Bay611.1430.581/71.6814.7209
French-Coach671.1430.581/71.6815.4218
German-Coach411.1448.691/72.1217.4312
Arabian471.1448.691/72.1218.4324
Belgian271.1477.471/72.6722489
Viatka1/071.5277.471/72.6727.4743
Thoroughbred2/0191.52155.41/73.7831.1962
Celtic2/071.52123.31/73.3730.7950
Norman2/0191.52123.31/73.3730.3917
Donkey3/071.52123.31/73.37331126
Burro3/0191.52123.31/73.3732.71085
Dobbin3/071.52195.71/74.2534.61229
Trotter3/0191.52195.71/74.2534.31188
Roan4/071.52123.31/73.3735.71348
Gotland4/0191.52123.31/73.3735.21295
Bali4/071.52155.41/73.7836.51393
Skyros4/0191.52155.41/73.78361340
Pony4/071.52246.91/74.7738.31522
Code WordPhase ConductorBare Neutral MessengerApprox.  Diameter of CableApprox. Weight
SizeNo. of WiresNominal Insulation ThicknessSizeNo. of WiresDiameter of Wires
AWG or KcmilNo.mmAWG or KcmilNo.mmmmkg/km
AAC/XLPE+AAAC
Walking4/0191.52246.91/74.7737.81470
Exmoor336.4192.03246.91/192.8946.82193
Breton336.4192.03394.51/193.6649.12402
AAC/XLPE+ACSR
Morochuca611.1466/11.6814.7221
Chola671.1466/11.6815.4229
Morgan411.1446/12.1217.4330
Hackney471.1446/12.1218.4342
Palomino271.1426/12.6722518
Albino1191.5216/1325.8672
Standardbred1/071.521/06/13.3728.6854
Costena1/0191.521/06/13.3728.3827
Chicoteagues2/071.522/06/13.7831.51053
Grullo2/0191.522/06/13.7831.11022
Mare3/071.523/06/14.2534.61301
Suffolk3/0191.523/06/14.2534.31260
Stallion4/071.524/06/14.7738.31614
Appaloosa4/0191.524/06/14.7737.81561
Gelding336.4192.034/06/14.7746.72285
Bronco336.4192.03336.41/183.4748.62396

PDF Download

PDF Download