N2XSEY NA2XSEY N2XSE2Y NA2XSE2Y Three Cores Cable are

Home > Products > Medium Voltage Cables > N2XSEY NA2XSEY N2XSE2Y NA2XSE2Y Three Cores Cable are

N2XSEY NA2XSEY N2XSE2Y NA2XSE2Y Three Cores Cable are

Three-core cables N2XSEY & NA2XSEY – safe and reliable.

XLPE insulated, copper or aluminum core, PVC sheathed.

Ideal for power distribution up to 36 kV.

IEC/VDE standard 3-core cables for industrial installations.

Durable armoured MV cables – N2XSEY / NA2XSE2Y available.

Application

N2XSEY, NA2XSEY, N2XSE2Y, and NA2XSE2Y are three-core medium voltage power cables designed for fixed installation in power distribution systems up to 12/20(24) kV or 18/30(36) kV. These cables are manufactured in accordance with DIN VDE 0276-620 / IEC 60502-2, ensuring high reliability and safety.

These cables feature copper (N2X…) or aluminum (NA2X…) conductors, XLPE insulation, and a copper wire screen with copper tape for effective electromagnetic shielding and fault current return paths. The difference between SEY and SE2Y lies in the outer sheath:

  • SEY uses PVC (Polyvinyl Chloride)
  • SE2Y uses PE (Polyethylene) for enhanced moisture resistance and mechanical durability.

These cables are UV-resistant, flame-retardant, and suitable for direct burial or installation in ducts, making them ideal for infrastructure, industrial plants, and utility distribution networks.

With continuous operation at 90°C, short-circuit tolerance up to 250°C, and high dielectric strength, these cables offer long service life, low capacitance, and reliable performance under tough environmental and electrical conditions.

Specifications

AspectDetails & Applications
Cable TypeN2XSEY / N2XSE2Y: Copper conductorNA2XSEY / NA2XSE2Y: Aluminum conductor
Number of Cores3 cores – individually insulated and laid up together
Conductor ClassClass 2 (stranded), per IEC 60228
Insulation MaterialCross-linked polyethylene (XLPE) – high thermal and electrical performance
Inner SheathExtruded PE (polyethylene) layer or thermoplastic bedding
ScreenIndividual copper wire + copper tape screen per core (for electromagnetic shielding and fault path)
ArmourNone (unarmoured)
Outer SheathBlack PE (polyethylene) or optionally PVC – UV, weather, and moisture resistant
Rated VoltageTypically 6/10 kV, 12/20 kV, or 18/30 kV
Operating TemperatureContinuous: 90°C; Short-circuit: up to 250°C
StandardsIEC 60502-2, VDE 0276-620, HD 620 S2
Flame RetardanceFlame-retardant according to IEC 60332-1; LSZH versions available
Typical Applications– Medium voltage power distribution in utility, industrial, and infrastructure networks– Suitable for underground installation, cable ducts, or outdoor use without mechanical protection
Naming Note“2Y” indicates double-layer PE sheath, offering enhanced mechanical & environmental protection



Parameter

6-10KV Medium Voltage Three Cor
Nom
nsulation hickness
Copper tape
thickness
Copper wire
screen area
Appro.Insulation diaNom
armor
thickness
Nom
sheath thickness
Appro
overall
diameter
Appro weight
(kg/km)
 
(mm)(mm)(mm)(mm)(mm)(mm)(mm)(mm)(mm)CUAL
256.053.40.11612.50.52.34432002700
357.13.40.11613.50.52.44637002000
508.253.40.11614.70.52.54943003400
709.93.40.11616.30.52.65352003900
9511.73.40.11618.10.52.85764004600
12013.13.40.11619.50.52.96174005200
15014.33.40.12520.70.536485005700
18516.33.40.12522.70.53.168100006500
24018.73.40.12525.30.53.374123007600
30020.93.40.12527.90.53.479146008800
40023.73.40.13531.10.83.7871870011300

 

Construction data 2XSE2Y/N2XSE2Y,A2XSE2Y/NA2XSE2Y 6/10; 12/20; 18/30 kV
Number of
conductors and nominal cross sec颅tion
Thickness of insula颅tionThickness
of
sheath
Nominal cross sec颅tion of
screen
Cable diameter approx.2XSE2Y,
N2XSE2Y
A2XSE2Y,
NA2XSE2Y
Mass of
Cu approx.
Mass of
cable
approx.
Mass of
Al approx.
Mass of
cable
approx.
Nxmm2mmmmmm2mmkg/kmkg/kmkg/kmkg/km
6/10 kV
3×35mm/16
3×50mm/16
3,4
3,4
2,5
2,5
16
16
46,4
48,8
1010 13632849
3348
298
404
2174
2437
3×70m/163,42,71653,0196842085842894
3×95mm/163,42,81657,1273252298093402
3×120mm/163,42,91660,33440610810233812
3x150rm/253,43,02564,24245728712574449
3×185mm/253×240rm/253,4
3,4
3,2
3,4
25
25
68,5
74,3
5311 69818632
10690
1579
2071
5086
6027
3×300mm/253,43,52579,686611276625896999
12/20 kV
3×35mm/165,52,81656,7101037142983038
3×50mm/16
3×70mm/16
5,5
5,5
2,9
3,0
16
16
59,3
63,3
136319684259
5153
404
584
3349
3839
3×95rm/16
3×120mm/16
5,5
5,5
3,1
3,2
16
16
67,4
70,6
2732 34406226
7162
809
1023
4399
4866
3x150rm/255,53,42574,74245843912575601
3×185rm/255,53,52578,85311983015796284
3×240mm/255,53,72584,569811199820717334
18/30 kV
3×50mm/168,03,31671,7136355054044596
3×70m/168,03,41675,8196864805845167
3×95mm/168,03,51679,8273276518095824
3×120m/168,03,71683,33440866510236369
3x150rm/258,03,82587,142451001912577181

PDF Download

PDF Download

WHY CHOOSE US

INOUIRY NOW

CONTACT US

24-hour online service

Own factory processing

PRODUCT CATEGORY

HOT-SALE PRODUCT

YJLV single-core MV cable for 3.6kV to 35kV power…

High-conductivity copper with XLPE insulation for…

Ideal for underground and overhead medium voltage …

Three-core YJV copper cable – stable power, long-term …

CONTACT USIMMEDIATELY