Application

PVC Insulated Unarmoured Power Cable is a versatile low-voltage cable designed for fixed installations in residential, commercial, and industrial environments. It features high-conductivity copper or aluminum conductors insulated with polyvinyl chloride (PVC), offering reliable electrical performance and basic environmental protection.

PVC insulation provides good dielectric strength, flame retardancy, and resistance to moisture, oils, and chemicals. It is suitable for operating temperatures up to 70°C, and short-circuit conditions up to 160°C. The insulation is flexible, lightweight, and easy to install, making the cable ideal for use in conduit systems, control panels, and trunking where additional mechanical protection is not required.

As an unarmoured cable, it is best suited for indoor use or protected environments where mechanical damage is unlikely. Common applications include lighting circuits, power outlets, distribution boards, and HVAC systems.

Specifications

AspectDetails & Applications
Conductor MaterialBare copper or aluminum, solid or stranded (IEC 60228 Class 1 or 2)
Insulation MaterialPVC (Polyvinyl Chloride) – good electrical insulation and flame retardancy
Cable TypeUnarmoured – without metallic protection layer, lightweight and flexible
Voltage RatingTypically 300/500 V or 0.6/1 kV for power and lighting circuits
Operating TemperatureContinuous: up to 70°C; short circuit: up to 160°C
Sheath MaterialPVC outer sheath (if present) – optional for added mechanical protection and color coding
StandardsIEC 60227, IEC 60502-1, BS 6004, VDE 0281
Electrical PropertiesStable insulation resistance, suitable for standard voltage power systems
Mechanical PropertiesModerate flexibility, resistant to abrasion and handling stresses
Chemical ResistanceGood resistance to moisture and many chemicals; not ideal for oils or UV without special sheathing
Typical Applications– Indoor fixed wiring in buildings- Power and lighting distribution- Conduit and trunking systems- Control panels and switchgear internal wiring



Parameter

Single core(unarmoured)
NOMINAL CROSS SECTIONDIAMETER OF CONDUCTOR (APPROX.)NOMINAL INSULATION THICKNESSNOMINAL PVC SHEATH THICKNESSOVERALL DIAMETER (APPROX.)WEIGHT OF CABLE (APPROX.)
MM2MMMMMMMMKG/KM
1×42.611.47.595
1×63.111.48120
1×10411.49165
1×16511.410230
1×256.31.21.412340
1×357.41.21.413450
1×508.81.41.414.5570
1×7010.61.41.416800
1×9512.41.61.518.51070
1×120141.61.5201300
1×15015.51.81.6221600
1×18517.421.7241980
1×24020.32.21.7272560
1×30022.72.41.8303180
1×40025.42.61.9334060
1×50028.82.82375140
1×63030.42.82.2426600
Two cores(unarmoured)
NOMINAL CROSS SECTIONDIAMETER OF CONDUCTOR (APPROX.)NOMINAL INSULATION THICKNESSNOMINAL PVC SHEATH THICKNESSOVERALL DIAMETER (APPROX.)WEIGHTOF CABLE (APPROX.)
MM2MMMMMMMMKG/KM
2×1.51.60.81.812205
2×2.520.81.813250
2×42.611.815330
2×63.111.816400
2×10411.817.5525
2×16511.820720
2×256.31.21.823.51030
2×357.41.21.825.51320
2×508.81.41.828.51670
2×7010.61.41.8322290
2×9512.41.61.9373060
2×120141.62403700
2×15015.51.82.2444500
2×18517.422.3485570
2×24020.32.22.5557180

 

Three cores(unarmoured)
NOMINAL CROSS SECTIONDIAMETER OF CONDUCTOR (APPROX.)NOMINAL INSULATION THICKNESSNOMINAL PVC SHEATH THICKNESSOVERALL DIAMETER (APPROX.)WEIGHT OF CABLE (APPROX.)
MM2MMMMMMMMKG/KM
3×1.51.60.81.813230
3×2.520.81.813.5280
3×42.611.815.5380
3×63.111.817470
3×10411.818.5630
3×16511.821880
3×256.31.21.824.51280
3×357.41.21.8271660
3×508.81.41.8302110
3×7010.61.41.9352980
3×9512.41.62403930
3×120141.62.1434780
3×15015.51.82.3485880
3×18517.422.4527230
3×24020.32.22.6599390
3×30022.72.42.76511620
3×40025.42.637214730

 

Three cores+1(unarmoured)
NOMINAL CROSS SECTIONDIAMETER OF CONDUCTOR (APPROX.)NOMINAL INSULATION THICKNESSNOMINAL PVC SHEATH THICKNESSOVERALL DIAMETER (APPROX.)WEIGHTOF CABLE (APPROX.)
MM2(3)MM(1)MM(3)MM(1)MMMMMMKG/KM
3x 16/1054111.8221000
3x 25/166.351.211.8261460
3x 35/167.451.211.8281830
3x 50/258.86.31.41.21.8322410
3x 70/3510.67.41.41.21.9363360
3x 95/5012.48.81.61.42.1414440
3×120/701410.61.61.42.2465580
3×150/7015.510.61.41.22.3496580
3×185/9517.412.41.61.42.5548200
3×240/12020.3141.61.42.66110570
3×300/15022.715.51.81.62.86713020
3×400/18525.417.421.63.17516560

 

Four cores(unarmoured)
NOMINAL CROSS SECTIONDIAMETER OF CONDUCTOR (APPROX.)NOMINAL INSULATION THICKNESSNOMINAL PVC SHEATH THICKNESSOVERALL DIAMETER (APPROX.)WEIGHT OF CABLE (APPROX.)
MM虏MMMMMMMMKG/KM
4×7010.61.42383760
4×9512.41.62.1444960
4×120141.62.3486110
4×15015.51.82.4537450
4×18517.422.6589220
4×24020.32.22.86511900
4×30022.72.437214730
4×40025.42.63.38118830
Multi-cores(unarmoured)
NOMINAL CROSS SECTIONDIAMETER OF CONDUCTOR (APPROX.)NOMINAL INSULATION THICKNESSNOMINAL PVC SHEATH THICKNESSOVERALL DIAMETER (APPROX.)WEIGHT OF CABLE (APPROX.)
MM2MMMMMMMMKG/KM
5×1.51.60.81.814.5300
7×1.51.60.81.815.5360
10×1.51.60.81.819460
12×1.51.60.81.819.5510
14×1.51.60.81.820570
19×1.51.60.81.822710
21×1.51.60.81.823770
24×1.51.60.81.825870
30×1.51.60.81.8261020
40×1.51.60.81.8291290
48×1.51.60.81.8321520
61×1.51.60.81.8351900
5×2.520.81.816375
7×2.520.81.817460
10×2.520.81.820590
12×2.520.81.821660
14×2.520.81.822740
19×2.520.81.824940
21×2.520.81.8251030
24×2.520.81.8271150
30×2.520.81.8291370
40×2.520.81.8321810
48×2.520.81.8362130
61×2.520.81.8392630

 

PDF Download

PDF Download

WHY CHOOSE US

INOUIRY NOW

CONTACT US

24-hour online service

Own factory processing

PRODUCT CATEGORY

HOT-SALE PRODUCT

Flexible and flame-retardant low-voltage power cables…

XLPE insulated LV cables for stable, long-term …

Heat- and moisture-resistant for indoor/outdoor use…

CONTACT USIMMEDIATELY