IEC/BS Standard XLPE Insulated LV Power Cable

Home > Products > Low Voltage Cables > IEC/BS Standard XLPE Insulated LV Power Cable

IEC/BS Standard XLPE Insulated LV Power Cable

XLPE insulated LV cables for stable, long-term performance.

Heat-resistant, durable, and ideal for underground wiring.

Low-voltage XLPE cables with excellent electrical insulation.

Factory-supplied XLPE power cables with IEC/BS standards.

Upgrade your wiring with high-quality XLPE insulated cables.

Application

Standard XLPE Insulated Low Voltage (LV) Power Cable is engineered for efficient and safe power distribution in residential, commercial, and industrial environments. It uses high-conductivity copper or aluminum conductors insulated with cross-linked polyethylene (XLPE), a material known for its superior thermal and electrical properties.

XLPE insulation offers excellent resistance to heat, moisture, chemicals, and mechanical stress, allowing the cable to operate at higher temperatures—up to 90°C continuous and 250°C under short-circuit conditions—without degradation. Compared to PVC-insulated cables, XLPE cables provide better current-carrying capacity, lower dielectric loss, and longer service life.

This type of cable is widely used in low-voltage power distribution systems, control panels, lighting networks, and fixed installations in dry or wet locations. It is suitable for indoor, outdoor, duct, or direct burial applications.

Specifications

AspectDetails
Conductor MaterialBare copper or aluminum, class 1 (solid) or class 2 (stranded), per IEC 60228
Conductor TypeSolid or stranded, depending on installation requirements
Insulation MaterialXLPE (Cross-Linked Polyethylene)
Voltage RatingLow Voltage – typically 0.6/1 kV
Operating TemperatureUp to 90°C continuous, short-circuit up to 250°C
Flame RetardancyXLPE is inherently thermoset and has good flame resistance
Sheath MaterialPVC or LSZH (Low Smoke Zero Halogen), depending on environment
StandardsIEC 60502-1, BS 5467, AS/NZS 5000.1, VDE 0276, SANS 1507
Thermal PropertiesBetter thermal resistance than PVC; retains shape and insulation at higher loads
Electrical PropertiesExcellent dielectric strength and low dielectric losses
Mechanical PropertiesStrong, abrasion-resistant, and maintains flexibility
Chemical ResistanceHigh resistance to moisture, oil, and chemicals
Typical Applications– Power distribution in buildings, plants, and industrial facilities
– Underground or ducted cable systems
– Internal wiring in switchgear, control panels
– Outdoor installations (when armored or sheathed properly)



Parameter

Nominal area of conductorMaximum conductor resistance at 20cThickness of insulationThickness of extruded beddingDia. Of armour wireThickness of outer sheathApprox.overall diameterApprox.cable weight
mm/kmmmmmmmmmmmkg/km
1.5*12.10.710.91.814.2355
1.512.10.710.91.814.6370
2.5*7.410.710.91.815400
2.57.410.710.91.815.4415
44.610.710.91.816.4480
63.080.710.91.817.6570
101.830.711.251.820.3820
161.150.711.251.822.31030
250.7270.911.61.826.31530
350.5240.911.61.828.51840
500.387111.61.830.92070
700.2681.111.6234.92670
950.1931.11.222.140.13660
1200.1531.21.222.243.74350
1500.1241.41.222.347.55160
1850.09911.61.42.52.553.36600
2400.07541.71.42.52.759.18100
3000.06011.81.62.52.864.19660
4000.04721.62.53.171.312000
5000.03662.21.63.153.379.815500

 

Maximum conducto
resistanc e at 20℃
Thicknes s of
insulation
Thickness of
bedding
Dia.Of
armour
wire
Thicknes s of outer sheathApprox.overall
diameter
Approx.cable
weight
Extruded beddingLapped
bedding
Extruded beddingLapped
bedding
Extruded beddingLapped
bedding
Ω/kmmmmmmmmmmmkg/km
12.10.70.80.91.313.3330
12.10.70.80.91.313.7350
7.410.70.80.91.414.4390
7.410.70.8 0.91.414.8415
4.610.70.80.91.415.9490
3.080.70.80.91.417.2580
1.830.70.81.251.519.6850
1.150.70.81.251.622.21110
0.7270.910.81.61.724.323.215201420
0.5240.910.81.61.826.925.819101790
0.387110.81.61.830.12924002250
0.2681.110.81.61.932.831.731002950
0.1931.11.20.822.138.236.743104060
0.1531.21.20.822.241.840.351704920
0.1241.41.40.82.52.346.444.566206290
0.09911.61.40.82.52.450.848.978607510
0.07541.71.40.82.52.656.95598109410
0.06011.81.60.82.52.761.859.51191011430
0.04721.60.82.52.969.266.91491014330
Nominal area of conductorMaximum
conductor
resistance at
20℃
Thickness of
insulation
Thickness of beddingDia.Of armour wireThickness of
outer sheath
Approx overall diameterApprox .cable weight
Extruded
bedding
Lapped
bedding
Extruded
bedding
Lapped
bedding
Extruded
bedding
Lapped
bedding
m㎡Ω/kmmmmmmmmmmmkg/km
1.5*12.10.70.80.91.313.3330 
1.512.10.70.80.91.313.7350 
2.5*7.410.70.8 0.91.414.4390
2.57.410.70.8 0.91.414.8415
44.610.70.80.91.415.9490
63.080.70.8 0.91.417.2580
101.830.70.81.251.519.6850
161.150.70.8 1.251.622.21110
250.7270.910.81.61.724.323.21520142
350.5240.910.81.61.826.925.81910179
500.387110.81.61.830.1292400225
700.2681.110.81.61.932.831.73100295
950.1931.11.20.822.138.236.74310406
1200.1531.21.20.822.241.840.35170492
1500.1241.41.40.82.52.346.444.56620629
1850.09911.61.40.82.52.450.848.97860751
2400.07541.71.40.82.52.656.9559810941
3000.06011.81.60.82.52.761.859.5119101143
4000.04721.60.82.52.969.266.9149101433

 

PDF Download

PDF Download

WHY CHOOSE US

INOUIRY NOW

CONTACT US

24-hour online service

Own factory processing

PRODUCT CATEGORY

HOT-SALE PRODUCT

IEC/BS standard XLPE cables, factory direct…

Steel tape or wire armour for enhanced mechanical…

Factory-supplied PVC power cables, IEC/BS compliant…

Ideal for industrial, commercial, and outdoor…

CONTACT USIMMEDIATELY