IEC/BS Standard PVC Insulated LV Power Cable
Home > Products > Low Voltage Cables > IEC/BS Standard PVC Insulated LV Power Cable
IEC/BS Standard PVC Insulated LV Power Cable
Durable PVC insulated LV cables for safe power distribution.
Flexible and flame-retardant low-voltage power cables.
Standard PVC insulation ensures reliable electrical safety.
Ideal for residential and commercial wiring projects.
Factory-direct PVC insulated cables with global certification.
Application
Standard PVC Insulated Low Voltage (LV) Power Cable is designed for reliable power distribution in residential, commercial, and industrial installations. It features high-quality copper or aluminum conductors, ensuring excellent electrical conductivity and low energy loss.
The conductor is insulated with flame-retardant PVC, which offers strong mechanical protection, excellent resistance to moisture, chemicals, and abrasion. This insulation maintains cable integrity under normal operating temperatures up to 70°C, making it suitable for indoor and outdoor fixed installations.
This LV power cable meets international standards such as IEC 60502-1 and BS 5467, ensuring safety and performance compliance. It is commonly used for wiring in buildings, lighting circuits, control panels, and power distribution networks.
With flexible construction and robust insulation, the cable resists impact and environmental stresses, ensuring long service life and minimal maintenance. Its smooth outer sheath also facilitates easy installation in conduit, trays, or direct burial applications.
Specifications
| Aspect | Details |
| Conductor Material | Bare copper (usually stranded), class 1 or 2 per IEC 60228 |
| Conductor Type | Stranded (flexible) or solid |
| Insulation Material | Polyvinyl Chloride (PVC) |
| Insulation Thickness | According to voltage rating and standard (e.g., 0.6/1 kV typical) |
| Sheath Material | PVC or sometimes flame-retardant PVC |
| Voltage Rating | Low Voltage, typically up to 1 kV (0.6/1 kV) |
| Operating Temperature | Typically -15°C to +70°C |
| Standards | IEC 60502-1, BS 6004, ASTM B3/B8 equivalents, IEEE 1202 (for flame tests) |
| Mechanical Properties | Good flexibility (especially stranded conductors), durable insulation resistant to abrasion |
| Flame Retardant Options | Standard PVC or flame-retardant PVC versions available |
| Typical Applications | – Residential, commercial, and industrial power distribution |
| – Wiring for appliances, lighting, and control circuits | |
| – Cable trays, conduit wiring | |
| – Internal wiring for switchboards, control panels | |
| Additional Features | Good chemical and moisture resistance; easy installation and termination |
Parameter
600 1000 V-Three core coppe-1
| Nominal area of conductor | conductor resistance at 20c | Thickness of insulation | Thickness of extruded bedding | Armour wire diameter | Thickness of outer sheath | Approx overall diameter | Approx cable weight |
| mm | km | mm | mm | mm | mm | mm | kg/km |
| 1.5* | 12.1 | 0.7 | 0.8 | 0.9 | 1.3 | 12.6 | 305 |
| 1.5 | 12.1 | 0.7 | 0.8 | 0.9 | 1.4 | 13.2 | 310 |
| 2.5* | 7.41 | 0.8 | 0.8 | 0.9 | 1.4 | 14 | 370 |
| 2.5 | 7.41 | 0.8 | 0.8 | 0.9 | 1.4 | 14.4 | 390 |
| 4 | 4.61 | 0.8 | 0.8 | 0.9 | 1.4 | 15.4 | 460 |
| 6 | 3.08 | 0.8 | 0.8 | 0.9 | 1.5 | 16.8 | 550 |
| 10 | 1.83 | 1 | 0.8 | 1.25 | 1.6 | 19.9 | 835 |
| 16 | 1.15 | 1 | 0.8 | 1.25 | 1.6 | 22.1 | 1050 |
| 25** | 0.727 | 1.2 | 1 | 1.6 | 1.7 | 26.8 | 1610 |
| 35** | 0.524 | 1.2 | 1 | 1.6 | 1.8 | 29.2 | 1950 |
| 50** | 0.387 | 1.4 | 1 | 1.6 | 1.9 | 32.7 | 2230 |
| 70** | 0.268 | 1.4 | 1 | 1.6 | 1.9 | 35.9 | 2790 |
| 95** | 0.193 | 1.6 | 1.2 | 2 | 2.1 | 42.1 | 3710 |
| 120** | 0.153 | 1.6 | 1.2 | 2 | 2.2 | 45.3 | 4580 |
| 150** | 0.124 | 1.8 | 1.2 | 2 | 2.3 | 49.1 | 5410 |
| 185** | 0.0991 | 2 | 1.4 | 2.5 | 2.4 | 54.4 | 6890 |
| 240** | 0.0754 | 2.2 | 1.4 | 2.5 | 2.5 | 60.7 | 8430 |
| 300** | 0.0601 | 2.4 | 1.6 | 2.5 | 2.7 | 66.3 | 10140 |
| 400** | 0.047 | 2.6 | 1.6 | 3.15 | 2.9 | 73.3 | 12500 |
600 1000 V-Three core coppe-2
| Nominal area of conductor | Maximum conductor resistance at 20℃ | Thickness of insulation | Thickness of bedding | Dia. Of armour wire | Thickness of outer sheath | Approx overall diameter | Approx cable weight | |||
| Extruded bedding | Lapped bedding | Extruded bedding | Lapped bedding | Extruded bedding | Lapped bedding | |||||
| mm2 | Ω/km | mm | mm | mm | mm | mm | kg/km | |||
| 1.5* | 12.1 | 0.7 | 0.8 | – | 0.9 | 1.4 | 13.3 | – | 340 | – |
| 1.5 | 12.1 | 0.7 | 0.8 | – | 0.9 | 1.4 | 13.7 | – | 355 | – |
| 2.5* | 7.41 | 0.8 | 0.8 | – | 0.9 | 1.4 | 14.6 | – | 415 | – |
| 2.5 | 7.41 | 0.8 | 0.8 | 0.9 | 1.4 | 15 | – | 435 | – | |
| 4 | 4.61 | 0.8 | 0.8 | – | 0.9 | 1.4 | 16.1 | – | 515 | – |
| 6 | 3.08 | 0.8 | 0.8 | – | 1.25 | 1.5 | 18.3 | – | 720 | – |
| 10 | 1.83 | 1 | 0.8 | – | 1.25 | 1.6 | 20.9 | – | 960 | – |
| 16 | 1.15 | 1 | 0.8 | – | 1.25 | 1.6 | 23.2 | – | 1240 | – |
| 25 | 0.727 | 1.2 | 1 | 0.8 | 1.6 | 1.7 | 25.6 | 24.5 | 1670 | 1550 |
| 35 | 0.524 | 1.2 | 1 | 0.8 | 1.6 | 1.8 | 28.1 | 27 | 2050 | 1920 |
| 50 | 0.387 | 1.4 | 1 | 0.8 | 1.6 | 1.9 | 31.9 | 30.8 | 2610 | 2460 |
| 70 | 0.268 | 1.4 | 1.2 | 0.8 | 2 | 2 | 35.5 | 34 | 3570 | 3360 |
| 95 | 0.193 | 1.6 | 1.2 | 0.8 | 2 | 2.1 | 40.3 | 38.8 | 4590 | 4360 |
| 120 | 0.153 | 1.6 | 1.2 | 0.8 | 2 | 2.2 | 43.5 | 42 | 5480 | 5230 |
| 150 | 0.124 | 1.8 | 1.4 | 0.8 | 2.5 | 2.4 | 47.8 | 45.9 | 6940 | 6600 |
| 185 | 0.0991 | 2 | 1.4 | 0.8 | 2.5 | 2.5 | 52.3 | 50.4 | 8270 | 7900 |
| 240 | 0.0754 | 2.2 | 1.6 | 0.8 | 2.5 | 2.6 | 59 | 56.7 | 10330 | 9870 |
| 300 | 0.0601 | 2.4 | 1.6 | 0.8 | 2.5 | 2.8 | 63.7 | 61.4 | 12480 | 11950 |
| 400 | 0.047 | 2.6 | 1.6 | 0.8 | 2.5 | 3 | 71.1 | 68.8 | 15560 | 14970 |
| 500 | 0.0366 | 2.8 | 1.8 | 0.8 | 3.15 | 3.6 | 78.8 | 76.1 | 19910 | 19130 |
600 1000 V-Three core coppe-3
| Nominal area of conductor | Maximum conductor resistance at 20℃ | Thickness of insulation | Thickness of bedding | Dia. Of armour wire | Thicknes s of outer sheath | Approx.overall diameter | Approx.cable weight | |||||||
| Phase | Neutral | Phase | Neutral | Phase | Neutral | Extruded | Lapped | Extruded bedding | Lapped bedding | Extruded bedding | Lapped bedding | |||
| m㎡ | Ω/km | mm | mm | mm | mm | mm | kg/km | |||||||
| 10* | 6 | 1.83 | 3.08 | 1 | 1 | 1 | – | 1.25 | 1.8 | 22.7 | – | 1080 | – | |
| 16* | 10 | 1.15 | 1.83 | 1 | 1 | 1 | – | 1.6 | 1.8 | 25.9 | – | 1530 | – | |
| 25 | 16 | 0.727 | 1.15 | 1.2 | 1 | 1 | 0.8 | 1.6 | 1.8 | 27.9 | 26.8 | 1930 | 1835 | |
| 35 | 16 | 0.524 | 1.15 | 1.2 | 1 | 1 | 0.8 | 1.6 | 1.9 | 31.5 | 30.4 | 2380 | 2270 | |
| 50 | 25 | 0.387 | 0.727 | 1.4 | 1.2 | 1 | 0.8 | 2 | 2 | 35.9 | 34.8 | 3250 | 3120 | |
| 70 | 35 | 0.268 | 0.524 | 1.4 | 1.2 | 1.2 | 0.8 | 2 | 2.1 | 39.4 | 37.9 | 4150 | 3945 | |
| 95 | 50 | 0.193 | 0.387 | 1.6 | 1.4 | 1.2 | 0.8 | 2 | 2.3 | 44.8 | 43.3 | 5360 | 5125 | |
| 120 | 70 | 0.153 | 0.268 | 1.6 | 1.4 | 1.4 | 0.8 | 2.5 | 2.5 | 49.3 | 47.4 | 6890 | 6575 | |
| 150 | 70 | 0.124 | 0.268 | 1.8 | 1.4 | 1.4 | 0.8 | 2.5 | 2.6 | 54 | 51.2 | 8110 | 7665 | |
| 185 | 95 | 0.0991 | 0.193 | 2 | 1.6 | 1.4 | 0.8 | 2.5 | 2.7 | 58.7 | 56.5 | 9730 | 9305 | |
| 240 | 120 | 0.0754 | 0.153 | 2.2 | 1.6 | 1.6 | 0.8 | 2.5 | 2.9 | 64.9 | 62.1 | 12030 | 11535 | |
| 300 | 150 | 0.0601 | 0.124 | 2.4 | 1.8 | 1.6 | 0.8 | 2.5 | 3.1 | 70.2 | 67.9 | 14660 | 13990 | |
| 300 | 185 | 0.0601 | 0.0991 | 2.4 | 2 | 1.6 | 0.8 | 2.5 | 3.2 | 70.4 | 68.1 | 14870 | 14350 | |
| 400 | 185 | 0.047 | 0.0991 | 2.6 | 2 | 1.8 | 0.8 | 3.15 | 3.4 | 80.2 | 76.6 | 19090 | 18125 | |
| 500 | 240 | 0.0366 | 0.0754 | 2.8 | 2.2 | 1.8 | 0.8 | 3.15 | 3.7 | 88.4 | 85.7 | 23300 | 22360 | |
600 1000 V-Three core coppe-4
| Nominal area of conducto r | Maximum conducto r resistan ce at20°c | Thi cknes s of insulati on | Thi ckness of bedding | Dia. Of armour wire | Thi cknes s of outer sheath | Approx.overa11 diameter | Approx.cable weight | |||
| Extruded bedding | Lapped bedding | Extruded bedding | Lapped bedding | Extruded bedding | Lapped bedding | |||||
| m㎡ | Ω/km | mm | mm | mm | mm | mm | kg/km | |||
| 1.5* | 12.1 | 0.7 | 0.8 | – | 0.9 | 1.4 | 14.1 | – | 385 | – |
| 1.5 | 12.1 | 0.7 | 0.8 | – | 0.9 | 1.4 | 14.5 | – | 400 | – |
| 2.5* | 7.41 | 0.8 | 0.8 | – | 0.9 | 1.4 | 15.5 | – | 470 | – |
| 2.5 | 7.41 | 0.8 | 0.8 | 0.9 | 1.4 | 16 | – | 495 | – | |
| 4 | 4.61 | 0.8 | 0.8 | – | 1.25 | 1.5 | 18.1 | – | 700 | – |
| 6 | 3.08 | 0.8 | 0.8 | – | 1.25 | 1.5 | 19.6 | – | 8300 | – |
| 10 | 1.83 | 1 | 0.8 | – | 1.25 | 1.6 | 22.4 | – | 1130 | – |
| 16 | 1.15 | 1 | 1 | – | 1.6 | 1.7 | 26.4 | – | 1650 | – |
| 25 | 0.727 | 1.2 | 1 | 0.8 | 1.6 | 1.8 | 27.9 | 26.8 | 2040 | 1890 |
| 35 | 0.524 | 1.2 | 1 | 0.8 | 1.6 | 1.9 | 31.5 | 30.4 | 2550 | 2400 |
| 50 | 0.387 | 1.4 | 1.2 | 0.8 | 2 | 2 | 36.3 | 34.8 | 3510 | 3300 |
| 70 | 0.268 | 1.4 | 1.2 | 0.8 | 2 | 2.1 | 39.4 | 37.9 | 4450 | 4220 |
| 95 | 0.193 | 1.6 | 1.2 | 0.8 | 2 | 2.2 | 44.6 | 43.1 | 5770 | 5510 |
| 120 | 0.153 | 1.6 | 1.4 | 0.8 | 2.5 | 2.4 | 49.1 | 47.2 | 7350 | 6970 |
| 150 | 0.124 | 1.8 | 1.4 | 0.8 | 2.5 | 2.5 | 53.5 | 51.6 | 8760 | 8390 |
| 185 | 0.0991 | 2 | 1.4 | 0.8 | 2.5 | 2.6 | 58.6 | 56.3 | 10530 | 10040 |
| 240 | 0.0754 | 2.2 | 1.6 | 0.8 | 2.5 | 2.8 | 64.2 | 61.9 | 13050 | 12520 |
| 300 | 0.0601 | 2.4 | 1.6 | 0.8 | 2.5 | 3 | 70 | 67.7 | 15880 | 15300 |
| 400 | 0.047 | 2.6 | 1.8 | 0.8 | 3.15 | 3.3 | 79.1 | 76.4 | 20710 | 20000 |
| 500 | 0.0366 | 2.8 | 1.8 | 0.8 | 3.15 | 3.9 | 88.8 | 86.1 | 25400 | 24720 |
600 1000 V-Three core coppe-5
| Nominal area of conduct or | Maximu m conduct or resistan ce at | Thickne SS of insulation | Thickness of bedding | Dia.Of armour wire | Thickne sS of outer sheath | Approx.overall diameter | Approx cable weight | ||
| dbedding | Lapped |bedding | d bedding | Lapped bedding | d bedding | |||||
| m㎡ | Ω/km | mm | mm | mm | mm | mm | kg/km | ||
| 1.5 | 12.1 | 0.7 | 0.8 | – | 1.25 | 1.8 | 18 | – | 601 |
| 2.5 | 7.41 | 0.8 | 0.8 | 1.25 | 1.8 | 19.2 | – | 707 | |
| 4 | 4.61 | 0.8 | 0.8 | – | 1.25 | 1.8 | 21.8 | – | 915 |
| 6 | 3.08 | 0.8 | 0.8 | – | 1.6 | 1.8 | 24 | – | 1197 |
| 10 | 1.83 | 1 | 0.8 | – | 1.6 | 1.8 | 26.5 | – | 1517 |
| 16 | 1.15 | 1 | 1 | – | 1.6 | 1.9 | 29.5 | – | 1948 |
| 25 | 0.727 | 1.2 | 1 | 0.8 | 1.6 | 2 | 33.4 | 29.4 | 2605 |
| 35 | 0.524 | 1.2 | 1 | 0.8 | 2 | 2.1 | 34.8 | 30.62 | 3283 |
| 50 | 0.387 | 1.4 | 1.2 | 0.8 | 2 | 2.2 | 39 | 34.62 | 4183 |
| 70 | 0.268 | 1.4 | 1.2 | 0.8 | 2 | 2.3 | 43.1 | 38.52 | 5394 |
| 95 | 0.193 | 1.6 | 1.2 | 0.8 | 2.5 | 2.6 | 50.1 | 44.92 | 7487 |
| 120 | 0.153 | 1.6 | 1.4 | 0.8 | 2.5 | 2.7 | 54.1 | 48.72 | 8935 |
| 150 | 0.124 | 1.8 | 1.4 | 0.8 | 2.5 | 2.9 | 59.1 | 53.32 | 10711 |
| 185 | 0.0991 | 2 | 1.4 | 0.8 | 2.5 | 3.1 | 64.9 | 58.72 | 12988 |
| 240 | 0.0754 | 2.2 | 1.6 | 0.8 | 2.5 | 3.3 | 72.2 | 65.62 | 16369 |
| 300 | 0.0601 | 2.4 | 1.6 | 0.8 | 3.15 | 3.6 | 80.7 | 73.52 | 20850 |
| 400 | 0.047 | 2.6 | 1.8 | 0.8 | 3.15 | 3.8 | 88.92 | 81.32 | 25630 |
| 500 | 0.0366 | 2.8 | 1.8 | 0.8 | 2.5 | 2.5 | 46.8 | 41.8 | 19916 |
PDF Download
PDF Download
WHY CHOOSE US