Bare Copper Conductor

Home > Products > Bare Conductor > Bare Copper Conductor

Bare Copper Conductor

Pure bare copper for maximum conductivity.

Ideal for grounding, power, and electrical projects.

High-purity copper wire with excellent flexibility.

Direct factory supply of solid and stranded copper.

Bare copper conductor – durable, efficient, and reliable.

Application

Bare copper conductor is a high-purity, uninsulated electrical conductor made from electrolytic grade copper, offering excellent electrical and thermal conductivity. With conductivity up to 100% IACS, it ensures minimal energy loss and is ideal for grounding, bonding, and power distribution systems.

Available in solid or stranded form, and in hard-drawn or annealed conditions, bare copper conductors provide flexibility and mechanical strength for diverse applications. They are corrosion-resistant in dry environments and perform reliably in both indoor and outdoor installations.

Common applications include grounding grids, lightning protection, overhead lines, and electrical substations. In grounding systems, it offers a low-resistance path to earth, improving safety and surge protection.

Manufactured in compliance with standards such as ASTM B3, ASTM B8, and IEC 60228, bare copper conductors are valued for their long service life, high conductivity, and full recyclability. As a trusted material in power and grounding infrastructure, they support stable and efficient electrical performance across a wide range of industries.

Specifications

AspectDetails
Material Composition99.9%+ pure Electrolytic Tough Pitch (ETP) Copper, high electrical & thermal conductivity
Conductor FormSolid or stranded (multi-wire), offering options for rigidity or flexibility
Surface FinishBare (uninsulated), optional tin coating to enhance corrosion resistance in harsh or underground environments
Mechanical PropertiesSoft-drawn (annealed) for maximum flexibility; hard-drawn for higher tensile strength and durability
Electrical ConductivityVery high, approximately 100% IACS (International Annealed Copper Standard)
Corrosion ResistanceNaturally forms a protective oxide layer; tinning adds improved resistance to oxidation and corrosion
Thermal ConductivityExcellent heat dissipation, suitable for high current carrying applications
Applicable StandardsASTM B3 (solid wire), ASTM B8 (stranded wire), IEC 60228 (conductor classes), BS EN 13602, CSA C22.2
Primary Applications– Grounding and earthing systems for fault and lightning current dissipation
– Electrical bonding for potential equalization
– Lightning protection conductors and grounding electrodes
– Power distribution components including busbars, substations, and switchgear
– Internal wiring and grounding in electrical panels
– Buried grounding grids in substations and industrial installations
Environmental SuitabilitySuitable for indoor/outdoor, buried installations; tinning recommended for corrosive or moist environments

 

Parameter

Hard drawn copper stranded wire
Nominal area of cross-section of stranded conductor/mm2Construction(stranding and wire diameter)number/mmOverall diameter  of conductor (approx.)
mm
Nominal mass per unit length kg/kmResistance at 20°C Nominal/Ω/kmResistance at 20°C Max/Ω/kmMinimum breaking load N
107/1.354.0589.821.7881.8293752
147/1.604.8126.21.2731.3035267
163/2.655.7148.31.0821.1066194
167/2.105.1142.41.1281.1545946
二十五7/2.106.3217.30.73910.75639073
三十二3/3.758.06296.90.54050.55212400
三十二7/2.467.38298.20.53860.549712442
三十五7 / 2.507.53080.52150.533712860
507/3.009.00 443.50.36220.370618520
5019/1.809435.80.37270.381917700
707/3.5510.65621.10.25860.264625930
7019/2.1010.5593.20.27380.280624090
9519/2.5012.50 840.70.19320.19834140
1007/4.3012. 90911.20.17630.18136540
12019/2.801410550.1540.157842830
12519/2 .9014.511310.14360.147145940
15019/3.201613770.1180.120855940
15037/2.2515.7513340.12330.126453880
18519/3.5517.7516950.095820.0981568860
18537/2 .5017.516470.099810.102466490

 

Nominal area of cross-section of stranded conductormm2Construction(stranding and wire diameter)number/mmOverall diameter of conductor (approx.)Nominal mass per unit lengthkg/kmResistance at 20°CNominalΩ/kmResistance at 20°CMaxΩ/kmMinimumbreaking loadN
123/2.304.95112.41.7431.786968
167/1.705.1143.31.3681.3998883
227/2.006198.30.98821.01112290
二十五7/2.106.3218.70.89590.917113550
三十7/2.306.9262.30.74690.764516260
三十五7 / 2.507.5309.90.63240.647119210
三十八7/2.607.8335,20.58470.598320780
四十五7/2.908.74170.46980.480924600
557/3.209.6507.80.38590.39529950
7019/2.1010.5596.80.33160.340335990
757/3.7011.1678.80.28870.295438010
9519/2 .5012.5845.90.23430.2451010
1007/4.3012.9916.90.21380.219551160
12019/2.801410610.18620.191460890
12519/2。9014.511380.17390.178465310
15019/3.201613860.14280.146579530
15037/2.2515.7513420.14930.153380490
18019/3.5017.516580.11960.122595140
18037/2.5017.516570.12090.124299330
20019/3.7018.518530.10680.1696100900
24019/4. 002021650.091530.09378117900

 

Nominal area of cross-setionmm2Wire diameterNominal mmWire diameterMax. mmWire diameterMin. mmNominal mass per unit length kg/kmResitance at20°C Ω/kmResitance at 20°C Ω/kmMinimum breaking loadN
1.431.351.3641.33712.7312.4112.66583
2.011.60 1.6161.58417.878.8389.018818
2.271.70 1.7171.68320.187.8297.988923
2.541.80 1.8181.78222.626.9837.1251035
3.462.10 2.1212.07930.795.130 5.2351409
3.982.252.2732.22835.354.4694.5581618
4.752.462.4842.43542.253.7393.8161932
4.912.50 2.5252.47543.643.620 3.6941997
5.512.652.6772.62449.033.2223.2862244
6.162.80 2.8282.77254.742.8862.9442505
6.612.90 2.9292.87158.722.600 2.7452687
7.073.00 3.030 2.970 62.842.5142.5652875
8.043.20 3.2323.16871.50 2.210 2.2543271
9.90 3.553.5863.51587.991.7951.8814027
11.043.753.7883.71398.191.6091.6414494
14.524.30 4.350 4.250 129.11.2241.2535675

 

PDF Download

PDF Download

WHY CHOOSE US

INOUIRY NOW

CONTACT US

24-hour online service

Own factory processing

PRODUCT CATEGORY

CONTACT USIMMEDIATELY