ACS-Aluminium-Clad Steel
Home > Products > Bare Conductor > ACS-Aluminium-Clad Steel
ACS-Aluminium-Clad Steel
ACS conductor – strength of steel, conductivity of aluminum.
Corrosion-resistant ACS for coastal and industrial zones.
Ideal for grounding, guy wires, and overhead lines.
Durable ACS cable with long service life.
Get ACS wire direct from the factory – fast delivery.
Application
ACS (Aluminum-Clad Steel) is a high-strength metal conductor consisting of a steel core covered with a pure aluminum layer. It combines the mechanical strength of steel with the electrical conductivity and corrosion resistance of aluminum. Its production process uses a metallurgical bonding method to tightly combine aluminum and steel to form a permanent composite material with excellent electrical conductivity, corrosion resistance and structural stability.
Compared with ordinary galvanized steel wire, ACS conductors have a longer service life in harsh environments (such as seaside, high salt fog, and acid rain areas). Its aluminum layer can effectively prevent steel oxidation and has good electrical connection performance. It is often used in conjunction with aluminum stranded wire to reduce electrochemical corrosion caused by potential difference.
ACS conductors are widely used in load-bearing components in overhead transmission lines, such as aluminum core stranded wire (ACSR), aluminum alloy conductor (AAACSR), OPGW optical cable core wire, etc. It can replace traditional galvanized steel wire to improve the corrosion resistance and service life of the line while reducing maintenance costs.
Specifications
| Standard | Organization | Material | Typical Application |
|---|---|---|---|
| ASTM B 415-1 | ASTM (USA) | Aluminum-Clad Steel Wire, Class A– ~10% aluminum by cross-section- Steel: high-strength carbon steel- Aluminum: metallurgically bonded (not coated) | Used in ground wires (shield wires), guy wires, and as core for overhead conductors where moderate conductivity and high strength are needed |
| ASTM B 415-2 | ASTM (USA) | Aluminum-Clad Steel Wire, Class B or C– Higher aluminum content than Class A- Improved conductivity, lower strength vs Class A | Used where higher corrosion resistance or conductivity is desired, such as coastal regions or long-span shield wires |
| ASTM B 502 | ASTM (USA) | Zinc-Coated (Galvanized) Steel Core Wire for ACSRNot ACS, but galvanized steel | Core wire used in ACSR conductors; not aluminum-clad, but zinc-coated for corrosion resistance |
Parameter
ASTM B 415-1 Round aluminum-clad steel wire (Class A coating, thinner, conductivity preferred) Commonly used for conductor core wire 🇺🇸 United States, 🇨🇦 Canada, 🇲🇽 Mexico, the entire Americas (such as Brazil, Peru, Chile)
| Size AWG | Diameter | Tensile Strength | Cross section | D C Resistance at 20℃ | Nominal Weight | Minimum Thickness of Aluminum Cladding | |||||
| in. | mm | ksi | N/mm | in2 | mm2 | Ω/km | Ib/1000ft | Ka/km | in | mm | |
| (CONDUCTIVITY = 20.3 % IACS) | |||||||||||
| 4 | 0.204 | 5.189 | 155 | 1070 | 0.03278 | 21.149 | 4.01 | 93.67 | 139.37 | 0.01022 | 0.259 |
| 0.188 | 4.775 | 160 | 1100 | 0.02776 | 17.909 | 4.735 | 79.32 | 118.02 | 0.0094 | 0.239 | |
| 5 | 0.182 | 4.62 | 165 | 1140 | 0.02599 | 16.766 | 5.058 | 74.25 | 110.49 | 0.0091 | 0.231 |
| 0.173 | 4.392 | 170 | 1170 | 0.02348 | 15.148 | 5.598 | 67.09 | 99.82 | 0.00865 | 0.22 | |
| 6 | 0.162 | 4.115 | 175 | 1210 | 0.02061 | 13.298 | 6.377 | 58.89 | 87.63 | 0.0081 | 0.206 |
| 0.155 | 3.934 | 180 | 1240 | 0.01884 | 12.158 | 6.975 | 53.84 | 80.12 | 0.00775 | 0.197 | |
| 7 | 0.144 | 3.665 | 185 | 1280 | 0.01635 | 10.551 | 8.037 | 46.73 | 69.53 | 0.00722 | 0.183 |
| 0.137 | 3.477 | 190 | 1310 | 0.01472 | 9.497 | 8.93 | 42.06 | 62.58 | 0.00685 | 0.174 | |
| 8 | 0.129 | 3.264 | 195 | 1340 | 0.01297 | 8.367 | 10.135 | 37.06 | 55.14 | 0.00643 | 0.163 |
| 9 | 0.114 | 2.906 | 195 | 1340 | 0.01028 | 6.631 | 12.787 | 29.37 | 43.7 | 0.00572 | 0.145 |
| 10 | 0.102 | 2.588 | 195 | 1340 | 0.00816 | 5.261 | 16.117 | 23.3 | 34.67 | 0.0051 | 0.129 |
| 11 | 0.091 | 2.304 | 195 | 1340 | 0.00646 | 4.168 | 20.343 | 18.46 | 27.47 | 0.00454 | 0.115 |
| 12 | 0.081 | 2.052 | 195 | 1340 | 0.00513 | 3.308 | 25.634 | 14.65 | 21.8 | 0.00404 | 0.103 |
ASTM B 415-2 Round aluminum-clad steel wire (Class B/C coating, thicker, corrosion resistance and strength preferred) Same as above; more suitable for lines in coastal, humid, and corrosive environments
| Size AWG | Diameter | Tensile Strength | Cross section | D C Resistance at 20℃ | Nominal Weight | Minimum Thickness of Aluminum Cladding | |||||
| in. | mm | ksi | N/mm2 | in2 | mm2 | Ω/km | Ib/1000 ft | Kg/km | in | mm | |
| (CONDUCTIVI | TY=27 % | IACS) | |||||||||
| 4 | 0.204 | 5.189 | 125 | 862 | 0.03278 | 21.149 | 3.019 | 84 | 124.99 | 0.0143 | 0.363 |
| 0.188 | 4.775 | 129 | 889 | 0.02776 | 17.909 | 3.566 | 71.13 | 105.84 | 0.01316 | 0.334 | |
| 5 | 0.182 | 4.62 | 133 | 917 | 0.02599 | 16.766 | 3.809 | 66.59 | 99.09 | 0.01273 | 0.323 |
| 0.173 | 4.392 | 137 | 945 | 0.02348 | 15.148 | 4.216 | 60.16 | 89.52 | 0.0121 | 0.307 | |
| 6 | 0.162 | 4.115 | 141 | 972 | 0.02061 | 13.298 | 4.802 | 52.82 | 78.59 | 0.01134 | 0.288 |
| 0.155 | 3.934 | 145 | 1000 | 0.01884 | 12.158 | 5.252 | 48.29 | 71.85 | 0.01084 | 0.275 | |
| 7 | 0.144 | 3.665 | 150 | 1034 | 0.01635 | 10.551 | 6.052 | 41.91 | 62.36 | 0.0101 | 0.257 |
| 0.137 | 3.477 | 154 | 1062 | 0.01472 | 9.497 | 6.724 | 37.72 | 56.12 | 0.00958 | 0.243 | |
| 8 | 0.129 | 3.264 | 156 | 1076 | 0.01297 | 8.367 | 7.632 | 33.23 | 49.45 | 0.009 | 0.228 |
| 9 | 0.114 | 2.906 | 156 | 1076 | 0.01028 | 6.631 | 9.629 | 26.34 | 39.19 | 0.00801 | 0.203 |
| 10 | 0.102 | 2.588 | 156 | 1076 | 0.00816 | 5.261 | 12.136 | 20.9 | 31.1 | 0.00713 | 0.181 |
| 11 | 0.091 | 2.304 | 156 | 1076 | 0.00646 | 4.168 | 15.319 | 16.56 | 24.64 | 0.00635 | 0.161 |
| 12 | 0.081 | 2.052 | 156 | 1076 | 0.00513 | 3.308 | 19.303 | 13.14 | 19.55 | 0.00566 | 0.144 |
| (CONDUCTIVITY = 30 % IACS) | |||||||||||
| 4 | 0.204 | 5.189 | 102 | 703 | 0.03278 | 21.149 | 2.717 | 79.74 | 118.65 | 0.01532 | 0.389 |
| 0.188 | 4.775 | 106 | 731 | 0.02776 | 17.909 | 3.209 | 67.52 | 100.47 | 0.0141 | 0.358 | |
| 5 | 0.182 | 4.62 | 110 | 758 | 0.02599 | 16.766 | 3.428 | 63.21 | 94.06 | 0.01364 | 0.347 |
| 0.173 | 4.392 | 114 | 786 | 0.02348 | 15.148 | 3.794 | 57.11 | 84.98 | 0.01297 | 0.329 | |
| 6 | 0.162 | 4.115 | 114 | 786 | 0.02061 | 13.298 | 4.322 | 50.14 | 74.6 | 0.01215 | 0.309 |
| 0.155 | 3.934 | 118 | 814 | 0.01884 | 12.158 | 4.727 | 45.84 | 68.21 | 0.01162 | 0.295 | |
| 7 | 0.144 | 3.665 | 122 | 841 | 0.01635 | 10.551 | 5.447 | 39.78 | 59.19 | 0.01082 | 0.275 |
| 0.137 | 3.477 | 126 | 869 | 0.01472 | 9.497 | 6.052 | 35.8 | 53.28 | 0.01027 | 0.261 | |
| 8 | 0.129 | 3.264 | 128 | 883 | 0.01297 | 8.367 | 6.869 | 31.54 | 46.94 | 0.00964 | 0.245 |
| 9 | 0.114 | 2.906 | 128 | 883 | 0.01028 | 6.631 | 8.666 | 25 | 37.2 | 0.00858 | 0.218 |
| 10 | 0.102 | 2.588 | 128 | 883 | 0.00816 | 5.261 | 10.923 | 19.84 | 29.52 | 0.00764 | 0.194 |
| 11 | 0.091 | 2.304 | 128 | 883 | 0.00646 | 4.168 | 13.787 | 15.72 | 23.38 | 0.0068 | 0.173 |
| 12 | 0.081 | 2.052 | 128 | 883 | 0.00513 | 3.308 | 17.372 | 12.47 | 18.56 | 0.00606 | 0.154 |
| (CONDUCTIVIT | Y= 40 % | IACS) | |||||||||
| 4 | 0.204 | 5.189 | 80 | 552 | 0.03278 | 21.149 | 2.038 | 65.95 | 98.13 | 0.02554 | 0.649 |
| 0.188 | 4.775 | 84 | 579 | 0.02776 | 17.909 | 2.407 | 55.85 | 83.1 | 0.0235 | 0.597 | |
| 5 | 0.182 | 4.62 | 88 | 607 | 0.02599 | 16.766 | 2.571 | 52.28 | 77.79 | 0.02274 | 0.578 |
| 0.173 | 4.392 | 92 | 634 | 0.02348 | 15.148 | 2.845 | 47.23 | 70.29 | 0.02161 | 0.549 | |
| 6 | 0.162 | 4.115 | 96 | 662 | 0.02061 | 13.298 | 3.241 | 41.47 | 61.7 | 0.02025 | 0.514 |
| 0.155 | 3.934 | 96 | 662 | 0.01884 | 12.158 | 3.545 | 37.91 | 56.41 | 0.01936 | 0.492 | |
| 7 | 0.144 | 3.665 | 98 | 676 | 0.01635 | 10.551 | 4.085 | 32.9 | 48.96 | 0.01804 | 0.458 |
| 0.137 | 3.477 | 98 | 676 | 0.01472 | 9.497 | 4.539 | 29.61 | 44.06 | 0.01711 | 0.435 | |
| 8 | 0.129 | 3.264 | 99.5 | 686 | 0.01297 | 8.367 | 5.152 | 26.09 | 38.82 | 0.01606 | 0.408 |
| 9 | 0.114 | 2.906 | 99.5 | 686 | 0.01028 | 6.631 | 6.5 | 20.68 | 30.77 | 0.0143 | 0.363 |
| 10 | 0.102 | 2.588 | 99.5 | 686 | 0.00816 | 5.261 | 8.192 | 16.41 | 24.41 | 0.01274 | 0.324 |
| 11 | 0.091 | 2.304 | 99.5 | 686 | 0.00646 | 4.168 | 10.34 | 13 | 19.34 | 0.01134 | 0.288 |
| 12 | 0.081 | 2.052 | 99.5 | 686 | 0.00513 | 3.308 | 13.029 | 10.32 | 15.35 | 0.0101 | 0.257 |
ASTM B 502 Aluminum-clad steel stranded wire (ACS Strand), made of B415 single wires, commonly used for overhead ground wires. Also suitable for 🇺🇸 American system countries, especially widely used in transmission ground wires and lightning protection systems
| SINGLE WVIRE AS PER ASTM B 502 STANDARD | |||||||||
| Diam etor | Tens ile Strength | Stress at 1% Extension | Resistivity | Density | |||||
| in. | mm | ksi | N/m㎡ | ksi | N/mm | Q.Cmil/H | n0m | lb/in3 | g/cm 3 |
| 0.0770-0.1289 | 1.956~3.274 | 195 | 1344 | 175 | 1206 | 51.01 | 84.8 | 0.2381 | 6.59 |
| 0.1290-0.1369 | 3.275~3.477 | 190 | 1310 | 170 | 1172 | ||||
| 0.1370-0.1443 | 3.478-3.665 | 185 | 1275 | 165 | 1137 | ||||
| 0.1444-0.1549 | 3.666-3.934 | 180 | 1241 | 160 | 1103 | ||||
| 0.1550-0.1620 | 3.935~4.115 | 175 | 1206 | 160 | 1103 | ||||
| 0.1621~0.1729 | 4.116~4.392 | 170 | 1172 | 155 | 1068 | ||||
| 0.1730~0.1819 | 4.393~4.620 | 165 | 1137 | 150 | 1034 | ||||
| 0.1820~0.1880 | 4.621~4.775 | 160 | 1103 | 145 | 1000 | ||||
| Coefficient of linear expansion :12.6×10/℃ Modulus of Elasticity : 23500 Ksl (162000 MPa) | Temperature coefficient of Resistance: 0.0036/℃C Minimum Aluminum Thickness : 10% of nominal wire radius | ||||||||
| SINGLE WIRE AS PER AS-3607 STANDARD | |||||||||
| Diameter (一) | Tensile Strength | Cross saction | DC Resistance a120℃ | Nominal Weight | Minimum Thickness of Aluminum Cladding | ||||
| SHd | Max | Min | N/mm2 | KN | mm | 0/km | Kg/km | in | |
| 1.6 | 1.64 | 1.56 | 1340 | 2.69 | 2.011 | 42.28 | 13.25 | 0.08 | |
| 1.75 | 1.79 | 1.71 | 1340 | 3.22 | 2.405 | 35.34 | 15.85 | 0.088 | |
| 2.25 | 2.29 | 2.21 | 1340 | 5.33 | 3.976 | 21.38 | 26.2 | 0.113 | |
| 2.5 | 2.54 | 2.46 | 1340 | 6.58 | 4.909 | 17.32 | 32.35 | 0.125 | |
| 2.75 | 2.791 | 2.709 | 1340 | 7.96 | 5.94 | 14.31 | 39.14 | 0.138 | |
| 3 | 3.045 | 2.955 | 1340 | 9.47 | 7.069 | 12.03 | 46.58 | 0.15 | |
| 3.25 | 3.299 | 3.201 | 1340 | 11.12 | 8.296 | 10.25 | 54.67 | 0.163 | |
| 3.5 | 3.553 | 3.448 | 1310 | 12.6 | 9.621 | 8.83 | 63.4 | 0.175 | |
| 3.75 | 3.806 | 3.694 | 1270 | 14.03 | 11.045 | 7.7 | 72.78 | 0.188 | |
| Coefficient of linear expansion :12.9×10*/℃ Modulus of Elasticity :23500 Ksi (162000 MPa) | Tem perature coefficient of Resistance: 0.0036℃ Minimum Aluminum Thickness : 10% of nominal wire radlus | ||||||||